D (mm) (mm) Cylinder model C D Mounting bolt size Cylinder model C D Mounting bolt size CVQM5010 CVQM325 45 M5 x 45L M6 x 60L 60 15 10 45 x 45L x 60L 60 20 15 50 x 50L x 65L 65 25 20 55 x 55L x 70L 70 30 25 60 x 60L x 75L 75 35 30 65 x 65L 12.5 x 80L 80 9 40 35 70 x 70L x 85L 85 45 40 75 x 75L x 90L 90 50 45 80 x 80L x 95L 95 75 50 85 x 85L x 120L 120 -100 75 110 x 110L x 145L 145 CVQM6310

Dimensions (mm) Weight (kg) Series Height Width Overall length MG Overall length 0.057 CXSJ6 42 + Stroke 32 13.4 CX Basic type 6 Additional dimension for each bore size compared to the basic type 2 mm (20) 3 mm (25) 5 mm (32) CXS6 0.095 58.5 + Stroke 37 16 Series CXS 6, 10, 15, 20, 25, 32 D0.114 CXSJ10 56 + Stroke 42 CXS basic type + 15 Width 10 CXS10 0.170 72 + Stroke 46 17 -X 0.219 CXSJ15 70

or less 80 or less 70 or less 80 or less 70 or less 80 or less 80 or less Single 2-position 5 (R1) 3 (R2) Double 1 (P) N.C.

There are no air cushion effects in the rotating ranges of 70 shown in the diagram.

The maximum piston speed for retraction is approximately 70% that of extension.

If this weight is applied, the deflection of the guide shaft will also have a large value. 12 60 350 16 70 500 20 125 900 25 125 900 32 140 1100 40 170 1900 8-27-6 7 Platform Cylinder Series CXT Construction !1 i @3 @0 !4 !

-1 AL-135H AL-136H AL-137H KA00813 (V120) OUT AL-130H-V Hexagon socket head cap screw Relief valve AL-133H-V FKM-70 or EPDM-70 Companion flange Phosphoric ester AL-135H-V e Seal (O-ring) Case AL-136H-V AL-137H-V w O-ring KA00728 (V120) IN Note 1) The material and nominal size notations are based on JISB2401.

Mechanical seal pump Impeller HRLE090-m-20/40 0.5 Usable range 50 Hz Circulating fluid pressure [MPa] 60 Hz 0.4 0.3 Usable range 60 Hz 0.2 50 Hz 0.1 Return port 0 0 10 20 30 40 50 60 70 Circulating fluid flow rate [L/min] * The pump capacity is the capacity of CH1 when 2 L/min are applied to CH2.

You can check piping leak and remove the air. 70 A Circulating Fluid Temperature Controller Thermo-chiller Standard Type HRS090 Series Self diagnosis function and check display For details, refer to page 80. Display of individual alarm codes Operation is monitored all the time by the integrated sensor.

During transportation/storage: 15C to 50C, 15% to 85% (But as long as water or circulating fluid are not left inside the pipings) During operation: 5C to 45C, 30% to 70% (However, use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature or circulating fluid temperature is 10C or less.) 6. In locations where condensation may occur. 7.

VAC (60 Hz) Three-phase 460 VAC (60 Hz) AMH AME Air flow capacity SCFM (m3/h [ANR]) Series Rated inlet condition Port size Outlet air pressure dew point Note) AMF 37F(2.8C) 45F(7.2C) 50F(10C) IDFB3E IDFB4E IDFB6E IDFB8E IDFB11E IDFB15E IDFB22E IDFB37E IDFB55E IDFB75E NPT3/8 10(17) 11(19) 12(20) ZFC NPT1/2 15(25) 16(27) 17(28) 25(43) 26(45) 28(47) SF 100F (37.8C) 100psi (0.7MPa) NPT3/4 41(70

70 90 90 8.4 13 12.5 12.5 13 13 5.4 6.5 8.5 8.5 11 11 22 23 26 25 35 35 27 35 52 52 66 66 30 41 50 50 70 70 20 26.7 35.5 35.5 45 47.5 25 35 40 40 30 30 30 38.4 38.4 20 26.7 35.5 35.5 45 47.5 9.8 14 18 20 24 24 91.4 121.9 153.9 155.9 226.9 240.9 40 53 70 75 90 95 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 1070 A

Length 136016-1A 136016-2A 136016-3A 136016-4A 136016-5A 136016-6A 136016-7A 136016-8A 136016-9A 136016-10A 16 14 1 SRH 28 2 42 3 SRP 56 4 70 5 SRF Tie-rod for centralized supply block 84 6 98 7 ITV 112 8 126 9 IC 140 10 For 1 station 14 mm x 1 station = 14 mm Length ITVH For adding a regulator Tie-rod part no.

Outline of IO-Link function 70 Communication specifications 70 Process data 71 IO-Link parameter setting 75 Maintenance 89 Forgotten the security code 89 Troubleshooting 90 Specifications 101 Dimensions 104 -1No.PF-OMA1011-A Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

-A-20 CH1) 8.5.2 HRL200-A-20 CH1 0.6 60 Circulating fluid outlet 0.5 50 Lifting head [m] 0.4 40 Pressure [MPa] 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Circulating fluid flow[L/min] Fig. 8-10 Pump capacity(HRL200-A-20 CH1) HRL Series Documents 8-9 HRX-OM-Y098 Chapter 8 Documents 8.5.3 HRL300A20 CH1 0.7 70 Circulating

leakage diameter (A) current (mA) HRL100-A-40 20 4 cores x AWG10 3-phase (4 cores x 5.5 mm2) HRL200-A-40 R5.5-5 380 to 415V including 30 AC ground HRL100/200-A-40 (50Hz/60Hz) M5 30 3-phase 4 cores x 460 to 480V AWG8 AC(60Hz) (4 cores x 8 mm2) HRL300-A-40 R8-5 40 including ground 1 Cable specifications are the examples when using the product at a continuous allowable operating temperature of 70

Cable specifications are the examples when using the product at a continuous allowable operating temperature of 70 oC, with an operating voltage of 600 V and two kinds of plastic insulated wires at an ambient temperature of 30 oC. Please select the proper size cables according to the actual condition.

/P.70 USB LAN 8 - 2.4 () 1 JXC-CPW JXCD1 1 JXC-CPW 1 DeviceNet JXC-CD-S T JXC-CD-T *1 1 DeviceNet *2 JXC-CD-S JXC-CD-T 1 *1 *2 [] (LEC-T1-3G) (LEC-W2) (USB ) P5062-5 2 3.4 (P.16) 3 4.1 Node Address/ Data Rate (P.18) 4PLC PLC 5 5.(P. 23) 9 - 6 DC24V LED LED PWR ALM LED 8.LED (P.31) JXCLEDALM DeviceNet SI I/O 16.

MHKL2-20D MHKL2-20D D80 60 70 Pressure 0.6 MPa 2050 Gripping force (N) 60 Holding force (N) Pressure 0.6 MPa Pressure 0.6 MPa 0.5 MPa 50 40 0.5 MPa 40 0.4 MPa 30 0.4 MPa 30 0.3 MPa 20 0.3 MPa 20 0.2 MPa 10 10 0.2 MPa 0 0 20 40 60 80 20 40 60 80 Gripping point L (mm) Gripping point L (mm) MHKL2-25D MHKL2-25D 100 120 Pressure 0.6 MPa Pressure 0.6 MPa 100 80 Gripping force (N) Gripping force

If operated beyond the limiting ranges, excessive impact will occur and this may cause damage to equipment. 2.00 25 1.50 20 1.00 0.50 0.00 20 30 40 50 60 70 80 90 100 Stroke (mm) Cushion Needle Adjustment Caution : Operating pressure 0.5MPa : Operating pressure 0.4MPa Graph 1 1.