Size: 3 (30), Valve Type: 1 (Normally Closed), Body Material: C (Brass), Seal Material: F (FKM), Port Size: 03 (Thread; 3/8), Thread Type: N (NPT), Rated Voltage: 3 [120 (110) VAC], Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor)
Function: 3 (3 Position Closed Center), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 5 (24 VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: N (NPT), CE-Compliant: Q (CE-Compliant)
Body Size: 50, Thread: N (NPT), Port: 06 (3/4), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 3 (Lubricator w/Drain Cock), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: C [Float Type Auto Drain (N.C.)], Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 3 (Lubricator w/Drain Cock), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: C [Float Type Auto Drain (N.C.)], Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 3 (Lubricator w/Drain Cock), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: C [Float Type Auto Drain (N.C.)], Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 3 (Lubricator w/Drain Cock), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Function: 3 (3 Position Closed Center), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 03 (Base Mounted w/Sub-plate 3/8, Side Piping), Thread: N (NPT)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 3 (Lubricator w/Drain Cock), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Function: 3 (3 Position Closed Center), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: None, Port Size: 10 (1), Thread: T (NPTF)
PFG200 is CE and UKCA compliant, with an IP65 front face when panel mounted (IP40 otherwise). 3~5 selectable flow ranges (sensor dependent), or custom user range; Analog sensor input: 1-5VDC; Analog output: 24VDC max (switch); 30VDC max (IO-Link); Flow units; L/min, L, gal/min, gal, cfm, ft³; Temperature units (for PF3W sensors): °C, °F; Display accuracy: ±5.0% of F.S.; Display repeatability
Function: 3 (3 Position Closed Center), Body Option: 00 (Base Mounted Plug-in), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: N (NPT)
Function: 3 (3 Position Closed Center), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: B (Bottom), Port Size: 04 (Sub-plate 1/2)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: DG (D + G), Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 36 (3 + 6), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2 FLOW CONTROL W/FITTING. SPD CONTROL W/FITTING, LOW SP. AIRLINE EQUIPMENT. AS***F 10/32 (MISC./OTHER). .01936 lb. BX.
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2 FLOW CONTROL W/FITTING. FLOW CONTROL W/FITTING. AIRLINE EQUIPMENT. AS***F 10/32 STANDARD (PT). .01543 lb. BB.
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2 FLOW CONTROL W/FITTING. SPEED CONTROL W/FITTING. AIRLINE EQUIPMENT. AS***F 10/32 STANDARD (PT). .01543 lb. BB.
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2 FLOW CONTROL W/FITTING. FLOW CONTROL W/FITTING. AIRLINE EQUIPMENT. AS***F 10/32 STANDARD (NPT). .01543 lb. BD.
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2 FLOW CONTROL W/FITTING. SPEED CONTROL W/FITTING. AIRLINE EQUIPMENT. AS***F 10/32 STANDARD (NPT). .01543 lb. BD.