Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER 1 1/2 , COPPER FREE, AIRLINE EQUIPMENT, AFF MAIN LINE FILTER, J6, AFF 1 1/2INCH COPPER-FREE, .00000 lb
pressureOperating pressure differential range(1) (Difference between tank pressure and line pressure)Vibration resistance(Pressure differential 0.3 MPa)Min. operating flow(2)(l/min (ANR))(3)Bowl capacity (cm3)(Capacity between levels)Recommended lubricantAmbient and fluid temperatureBowl materialWeight (kg)Accessory (Standard)Auto feed lubeALF80011 411 2Air1.5 MPa0.7 MPa0.1 to 0.6 MPa1 G (9.81 m/
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PREC REG 1-1/2 NPT, AIRLINE EQUIPMENT, AR(PILOT) PILOT REGULATOR, JB, AR(PILOT) 1 1/2STANDARD (PT), 5.50000 lb, ModelPort sizeFluidProof pressureMax. operating pressureSet pressure range (MPa) (1)Air consumption (for bleed hole) (2)Pressure gauge port sizeAmbient and fluid temperatureConstructionMass
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: P (Stop Valve), Thread: Rc, Port Size: 03 (3/8), Flow Switch Output: CT (Integrated Display; Out 1: NPN; Out 2: (Analog 1 to 5 V) ⇔ Analog 1 to 5 V ; Temperature Sensor: Yes), Lead Wire: N (without Lead Wire), Flow Switch Unit: M (Integrated Display, IO-Link Campatible; Instantaneous Flow: L/min; Accumulated
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: Rc, Port Size: 03 (3/8), Flow Switch Output: L2 (Integrated Display IO-Link Compatible; Out 1: IO-Link/Switch Output (N/P); Out 2: Switch Output (N/P) ; Temperature Sensor: None), Lead Wire: N (without Lead Wire), Flow Switch Unit: M (Integrated Display,
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5~4L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: Rc, Port Size: 03 (3/8), Flow Switch Output: AT (Integrated Display; Out 1: NPN; Out 2: (NPN) ⇔ NPN ; Temperature Sensor: Yes), Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: M (Integrated Display, IO-Link Campatible; Instantaneous
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: None, Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: FT (Integrated Display; Out 1: PNP; Out 2: (Analog 4 to 20 mA) ⇔ Analog 4 to 20 mA ; Temperature Sensor: Yes), Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: M (Integrated Display, IO-Link Campatible; Instantaneous
Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: N (NPT), Port Size: 03 (3/8), Flow Switch Output: L2T (Integrated Display IO-Link Compatible; Out 1: IO-Link/Switch Output (N/P); Out 2: Switch Output (N/P) ; Temperature Sensor: Yes), Lead Wire: Q [with M12-M8 conversion Lead Wire (0.1m)], Flow Switch Unit: M
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter), Operation Manual: K (Operation Manual, Calibration Certificate)
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Series: 25A-ISE20, Rated Pressure Range: CH (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specifications: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Series: 25A-ISE20, Rated Pressure Range: C (-0.1 to 1 MPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specifications: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Series: 25A-ISE20, Rated Pressure Range: C (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specifications: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Series: 25A-ISE20, Rated Pressure Range: C (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specifications: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter), Operation Manual: K (Operation Manual, Calibration