SMC Corporation of America
Elite Part Number Search
Search Results "LEHS32K3-8-R5CE17"

Port size on the side of main fluid Rc 3/8 G 3/8 NPT 3/8 NPTF 3/8 3/8" tubing 3/8" tubing 3/8" tubing 3/8" tubing 1/2" tubing 1/2" tubing 1/2" tubing 1/2" tubing Connection size in the side of air 03 F03 Rc 1/4 Threads G 1/4 Threads NPT 1/4 Threads PA331 (Assembled in normal environment) PAP331 (Assembled in clean room) For areas where it is not possible to manually operate the reset button

Double wiring specification Double wiring specification 04 05 08 09 4 stations 8 stations 5 stations 9 stations Specified layout (up to 16 solenoids possible) Specified layout (up to 8 solenoids possible) ... ... ... ... 08 16 8 stations 16 stations Note 1) Double wiring specifications: Single, double and 3 position solenoid valves can be used at all of the manifold stations.

Note 2) Number of terminals 1 2 8 terminals in 1 row 16 terminals in 2 rows 1 to 4 stations (double), 8 stations (single) 5 to 8 stations (double), 16 stations (single) Note) The number of terminal blocks can be chosen regard-less of station qty.

C6 (One-touch fitting for 6) C8 (One-touch fitting for 8) B7 (One-touch fitting for 1/4") C9 (One-touch fitting for 5/16") Port size Rc 1/8 4(A), 2(B) port Flow Characteristics Port size Manifold C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R) 1(P), 5/3(R) port 2(B), 4(A) port VV5Z5-40 VV5Z5-41 VV5Z5-42-C6 VV5Z5-42-C8 1/8 1/8 C6 C8 0.59 0.55

3000 12.5 15 1/4 1/4 30 =0.7 6 10 1/4, 3/8 500 4 20 0.5 0.1 0.3 AS3000, AS3500 (12.3) AS4001F (16) AS320 (13) 10 10 1/4, 3/8 32 1000 8 REA AS3000,AS3500 (12.3) AS4000 (25.5) AS5000 (74) AS5000 (74) AS5000 (74) AS321F (10) AS331F (10) AS4001F (16) AS320 (13) 1500 2000 2500 3000 12 16 20 24 1/4, 3/8 3/8 3/8 3/8 0 REB 1,000 2,000 3,000 Maximum speed Vmax (mm/s) REC 40 8 10 1/4, 3/8 CY 500 40

Port Size Ejector system Vacuum pump system Metric Inch Metric Inch PV 6 1/4" 6 1/4" V 6, 8 1/4", 5/16" 6, 8 1/4", 5/16" EXH (Port exhaust) 8 5/16" If the sound absorbing material is clogged, it will cause a reduction in the ejector performance.

(mm) Connection thread R Model A M Weight (g) Note) D2 L1 L2 10 D1 KRL06-02S KRL06-01S 1 8 12 22 33 13 21 35 25 26 36 25.5 23 27 29 24.5 28.5 30.5 27 30 32 36 31 33 37 10 20 29 27.5 1 4 19 4.2 14 17 12 14 17 12.8 6 Applicable tubing 9.0 3 8 1 8 KRL06-03S 28 14.9 KRL08-01S KRL08-02S KRL08-03S KRL10-01S KRL10-02S KRL10-03S 1 4 3 8 1 8 1 4 3 8 30 31.5 32 33 34.5 15.2 12 23 8 20.5 21.6 14.9 21.6

47 32 13 10 55 45 10 17 45.5 186 40 6 8 37.5 5.5 8 6.8 28 D32 M10 x 1.25 22 22 19.5 42.5 47 32 13 11 55 45 12 17 49.5 199 40 6 8 46.5 5.5 10 6.8 28 40 M14 x 1.5 24 26.5 21 51 54 41 16 12.5 75 50 14 22 55.5 227 55 8 10 56.2 7 12 7 30 -X NN P S X Y Z ZZ Bore (mm) 20 M20 x 1.5 1/8 146 20 8 21 215 Individual -X 25 M26 x 1.5 1/8 146 20 8 25 219 32 M26 x 1.5 1/8 159 20 8 25 232 40 M32 x 2 1/4 181

47 32 13 10 55 45 10 17 45.5 186 40 6 8 37.5 5.5 8 6.8 28 D32 M10 x 1.25 22 22 19.5 42.5 47 32 13 11 55 45 12 17 49.5 199 40 6 8 46.5 5.5 10 6.8 28 40 M14 x 1.5 24 26.5 21 51 54 41 16 12.5 75 50 14 22 55.5 227 55 8 10 56.2 7 12 7 30 -X NN P S X Y Z ZZ Bore (mm) 20 M20 x 1.5 1/8 146 20 8 21 215 Individual -X 25 M26 x 1.5 1/8 146 20 8 25 219 32 M26 x 1.5 1/8 159 20 8 25 232 40 M32 x 2 1/4 181

47 32 13 10 55 45 10 17 45.5 186 40 6 8 37.5 5.5 8 6.8 28 D32 M10 x 1.25 22 22 19.5 42.5 47 32 13 11 55 45 12 17 49.5 199 40 6 8 46.5 5.5 10 6.8 28 40 M14 x 1.5 24 26.5 21 51 54 41 16 12.5 75 50 14 22 55.5 227 55 8 10 56.2 7 12 7 30 -X NN P S X Y Z ZZ Bore (mm) 20 M20 x 1.5 1/8 146 20 8 21 215 Individual -X 25 M26 x 1.5 1/8 146 20 8 25 219 32 M26 x 1.5 1/8 159 20 8 25 232 40 M32 x 2 1/4 181

inputs) 2 0 EX600-DY#B (8 outputs) 0 1 EX600-DY#E Digital output unit (16 outputs) 0 2 EX600-DY#F (16 outputs) 0 2 EX600-DM#E (8 inputs/8 outputs) 1 1 Digital I/O unit EX600-DM#F (8 inputs/8 outputs) 1 1 -79No.EX-OMA1023 Allocated bytes (continued) Allocated bytes Unit Unit part number Input Output EX600-AXA 4 (2 bytes per channel) 0 (2 channels) Analogue input Unit EX600-AXB 8 (2 bytes per

ZPT04U 4 4.8 1.6 3 6 5 8 0.8 D E E P T Y P E ZPT06U 6 7 2.5 3 6 5 8 0.8 Model A B C D E F G Y ZPT08U 8 9 2.5 3 6 5 8 1 ZPT10D 10 12 15 24 35.5 58.5 71.5 6 ZPT16D 16 18 16 25 36.5 59.5 72.5 7 Courtesy of Steven Engineering, Inc. !

Flow Rate and Effective Area AS12 1F-M3 AS13 1F-M3 AS12 1F-M5 AS13 1F-M5 AS22 1F-01 AS23 1F-01 AS22 1F-02 AS23 1F-02 AS32 1F AS33 1F AS42 1F AS43 1F Model Metric size 3.2, 4 3.2, 4, 6 3.2, 4 6, 8, 10 8,10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8" 5/32" 1/8", 3/16" 1/8" 5/32" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 3/8" 1/4" 1/4", 5/32" Controlled flow (Free flow

Class Symbol PAF341S 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 PAF541S PAF341S PAF541S tubing size (mm) tubing size (inch ) SMC SMC SMC 4 4 5 5 6 6 1 2 1 2 1 2 4 4 5 5 6 6 A B A B A B 1/2" x 3/8" 3/8" x 1/4" Panel mount union U P 3/4" x 5/8" Union 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" SMC Note) Select the fitting after confirming the IN / OUT side fitting size and fitting type.