101 kPa500 kPaAir/Non-corrosive, non-flammable gas12 to 24 VDC ?10%, Ripple (P-P) 10% or less (With power supply polarity protection)17 mA or less at 24 VDC5 ms or less?1% F.S. or lessEnclosureOperating temperature rangeOperating humidity rangeVibration resistanceImpact resistance?3% F.S. or less1000 VAC for 1 min.
The settings of the master pressur, 2-Color Hi Precision Dig Pres Switch, PRESSURE SWITCH, ISE40, ISE40A, 841, 101 lb
Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125, 140, 160 , Standard stroke (mm): 10 through 300 , Through hole mount, Auto switch capable, PISTON ASSEMBLY, COMPACT CYLINDER, 493, 101 lb
10Max. 14MPaFH540-10FH541-101 1/432 (1 1/4B)120
ModelPort size Note)Rated flow rate (l/min) INLETOUTLETFH990-101 1/2B1 1/4B150
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread, Connector Type: S (M12 Connector Type)
System: P (Vacuum Pump System, Single Unit), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: None, Pump System PE Port Female Thread: w/o Option, Vacuum Break Flow Adjustment: K (Vacuum
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover)
Series: 25A-ZSE20, Rated Pressure Range: B (0 to -101 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specifications: M (SI Unit Only), Piping Specifications: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Accessories: C (Fork Lever-type Fitting M), External Scale Plate: H (w/External Scale Plate), LCD Window: W (Body w/LCD Window), Connection, Air - Electric: 3 (NPT1/4 - NPT1/2), ATEX Temperature: T6 [ATEX Temperature T6 (-20 to 60°C)]
Size: 1 (10), Type: 1 (Body Ported), Body Material: S (Stainless Steel), Orifice Diameter and Port Size: 101 (Orifice: 1.4mm; Port: 1/8), Thread: F (G), Voltage: 5 (24VDC), Electrical Entry: DS (DIN Terminal, with Surge Voltage Suppressor), Bracket: B (with Bracket)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 1 (0 to -101 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 09 (ø5/16 One-touch Fitting, Inch), Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure Supply: w/o Option, Vacuum
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6H (ø6 One-touch Fitting, Straight Type), Lead Wire: w/o Lead Wire, Bracket: A2 (Bracket B, Horizontal Mounting)
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 09 [ø5/16 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow