SMC Corporation of America
Elite Part Number Search
Search Results "PSE561-C01-28"

SI Unit Dimensions / Parts Description EX500-Q01 EX500-Q02 Position indicator LED Position indicator LED SI UNIT COM PWR EX500 series COM PWR 2 x M4 (mounting hole) 66 80.3 80.3 36 28 64.4 64.4 Branch connector (M12, 8 pins, socket) Branch connector (M12, 8 pins, socket) 0 0 Branch connector (M12, 8 pins, plug) Branch connector (M12, 8 pins, plug) 1 1 60 60 85.7 44 1688 Decentralized Serial

Tightening Torque for Piping Caution Caution Connection Proper tightening Proper tightening torque (N m ) thread Rc 1/4 8 to12 Rc 3/8 15 to 20 Rc 1/2 20 to 25 Rc 3/4 28 to 30 Mounting Follow the procedure of the manufacture when fittings other than SMC is used. 5.

No.EX-OMC0002-C PRODUCT NAME CompoBus/S compatible SI unit MODEL/ Series/ Product Number EX12#-SCS# Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 9 Mounting and Installation 11 Wiring 11 Settings 14 Maintenance 17 Troubleshooting 24 Specification 27 Specifications 27 Dimensions 28 -1No.EX-OMC0002-C Safety Instructions These safety instructions

(PE) port of the solenoid valve is significantly restricted or blocked, the valve operation may become abnormal. 1/4 8 to 12 3/8 15 to 20 1/2 20 to 25 3/4 28 to 30 Mounting 1 36 to 38 1. Operation manual 1 1/4 40 to 42 1 1/2 48 to 50 2 48 to 50 Install the products and operate them only after reading the operation manual carefully and understanding its contents.

Warning Rc1/8 7 to 9 Rc1/4 12 to 14 Rc3/8 22 to 24 Rc1/2 28 to 30 6. Piping to products When piping to a product, avoid mistakes regarding the supply port, etc. 6 No.VF1000-OMN0002-A VF1000/3000/5000 Series Precautions for 5 Port Solenoid Valve Be sure to read before handling. Refer to main text for detailed precautions on every series. 9.

DIMENSIONS (Accessory) (Port size) Maintenance space Drain Dimensions Model Standard specifications 1/81/4 1/43/8 1/43/81/2 3/4 , AFM20-A 40 87.6 9.8 20 45 AFM30-A 53 115.1 14 26.7 30 50 AFM40-A 70 147.1 18 35.5 38.4 75 AFM40-06-A 75 149.1 20 35.5 38.4 75 Model Bracket mount dimensions AFM20-A 30 27 22 5.4 8.4 40 2.3 28 AFM30-A 41 35 23 6.5 13 53 2.3 30 AFM40-A 50 52 26 8.5 12.5 70 2.3

Cylinder tube gasket Rolled steel plate Brass/ Aluminum alloy Electroless nickel plated/Chromated Fluoro rubber 24 O-ring 3 Piston Fluoro rubber 25 O-ring Fluoro rubber Piston seal 4 Hexagon socket head set screw Hexagon socket head cap screw 26 Stainless steel Special bearing Wear ring 5 Stainless steel Shaft 6 Stainless steel 27 Stainless steel/Brass Cushion ring 7 /Electroless nickel plated 28

Manufacturers of friction fittings/Models Size Eyesell (Mechanical lock) Miki Pully (ETP bushing) Nabeya Industry (Clamp lock) Adjusting angle per 1 rotation of angle adjusting screw Size MA12 X 26 32 CLH-12 X 18 ETP-K-12 32 40 5.7 4.8 40 MA14 X 28 CLH-14 X 23 ETP-K-14 Consult the manufacturers concerning further information like on specifications.

B C D E F With bracket Port size G H I J 1 8 1 4 1 4 3 8 10 VXA21 VXA22 , , 18 21 9 10.5 40 45 21 27 55 62 64 71 11 13 36 46 46 56 11.5 Dimensions (Orifice Size: 8 mm, 10 mm) VXA225/VXA226 Thread fixed: (VXA2262 0-04 only) 2-M5 x 0.8 depth 8 Dimension of view from A Pilot port Port size P Rc , With bracket E Port size View from A Model A B C D VXA22 52 60 02 03 VXA226 -04 2 0 1 4 3 8 22 28

Riyadi Putera Makmur Jalan Hayam Wuruk Komplek Glodok Jaya No. 27-28 Jakarta 11180 Indonesia TEL: 021-625 5548 FAX: 021-625 5888 EGYPT (Distributor) Saadani Trading & Ind. Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt TEL: 3-548-50-34 FAX: 3-548-50-34 PAKISTAN (Distributor) Jubilee Corporation First Floor Mercantile Centre, Newton Road Near Boulton Market P.O.

Note 28) Selected bar (high voltage power supply module) ION/HV to display is turned off. Note 29) Selected bar (high voltage power supply module) stops the ion generation. 2)Changing to the setting mode For IZT41-L/42-L, refer to the IO-Link dedicated instruction manual.

No Thread IMPERIAL Code : Thread Form 00 : None (No reduction in METRIC Code : Thread Form METRIC Code : Thread Form Code : Thread Form 27 : 3/4-10 60 : M3 x 0.35 88 : M14 x 1.5 piston rod diameter) 28 : 3/4-16 61 : M3 x 0.5 89 : M20 x 1.5 01 : 2-56 29 : 7/8-9 62 : M4 x 0.5 90 : M12 x 1.25 02 : 2-64 30 : 7/8-14 63 : M4 x 0.7 91 : M42 x 1.5 03 : 4-40 31 : 1-8 64 : M5 x 0.5 92 : M24 x 3.0 04

For G thread, be sure to use this adapter. 3.3 Installation HRS Series 3-28 DOC1001322 Chapter 3 Transport and Setting Up How to connect piping Hold the each piping port with a wrench and tighten the piping. Connection port Sealant Note: When using the Y strainer of the accessory, fasten it on the return port.

VV5Q11 (L4) (L3) L2 (5.25) (12) 13 27 28 L1 Indicator light 63.5 23.5 10.5 (n-1) x 10.5 1.5 Manual override A A A B A B A B A B A FG + + 0V 24V SMC S E R I A L U N I T MODEL SC (SI No.EX120-STA1) 2 93.5 66 64 ERR T/R RUN (35) (5.5) 0 1 DIP SW. 4 x M4 mounting hole 61.5 4.5 Drawing shows a SC case.

Release side Pad side W Features 4 I N D E X 4 Port Solenoid Valve Series SJ2000/3000 Common Specifications P.1 Connector Wiring Diagram P.3 Construction P.4 D-sub Connector / Flat Ribbon Cable / PC Wiring Plug-in Connector Type Manifold How to Order P.10 Manifold Electrical Wiring P.12 Dimensions P.13 PC Wiring System with Power Supply Terminal How to Order P.26 Manifold Electrical Wiring P.28

Table 3-10 Piping port size Description Port Recommended Recommended piping size*1 tightening torque specifications Circulating fluid outlet port Rc1/2 28 to 30Nm 1.0MPa or more Circulating fluid return port Rc1/2 28 to 30Nm 1.0MPa or more Facility water inlet port *2 Rc3/8 22 to 24Nm 1.0MPa or more (Supply puressure: 0.3 to 0.5MPa) Facility water outlet port *2 Rc3/8 22 to 24Nm 1 For NPT

HRLE090-Wm-m Approx. 20 Refer to Facility water system in the specifications on pages 10 and 12. 28-1 A HRLE Series Specific Product Precautions 4 Be sure to read this before handling the products. Refer to the back cover for safety instructions.

(Hook spanner Nominal: 25/28) 2) Remove the baffle element Rotate the baffle by hand and counterclockwise to remove the baffle and element. Assembly 3) Mount the element. Mount the element to the element guide. AF10 4) Mount the baffle. Hold the baffle by hand to rotate it clockwise and mount the element. Baffle has mount direction. See disassembly drawing.

BUSY Release Hold External Lock Speed Cut-off stop during positioning operation. 0 mm/s 28 Series LECP1 Options: Actuator Cable [Robotic cable, standard cable for step motor (servo/24 VDC)] Controller side LE-CP/Cable length: 1.5 m, 3 m, 5 m 1 3 5 LE CP 1 (14.2) (Terminal no.)

(Hook spanner Nominal: 25/28) 2) Remove the baffle element Rotate the baffle by hand and counterclockwise to remove the baffle and element. Assembly 3) Mount the element. Mount the element to the element guide. AF10 4) Mount the baffle. Hold the baffle by hand to rotate it clockwise and mount the element. Baffle has mount direction. See disassembly drawing.