A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking, CYL, PIN CLAMP, PIN CLAMP CYLINDER, 381, 0.94 lb
A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking, Cylinder, Pin Clamp, PIN CLAMP CYLINDER, 381, 2.14 lb
A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking, CYL, PIN CLAMP, PIN CLAMP CYLINDER, 381, 2.8 lb
A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking, CYL, PIN CLAMP, PIN CLAMP CYLINDER, 381, 2.8 lb
A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking, CYL, CLAMP, PIN CLAMP CYLINDER, 381, 2.31 lb
A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking, CYL, CLAMP, PIN CLAMP CYLINDER, 381, 2.31 lb
The multi-stage ZL series is a high-efficiency vacuum generator, which operates at 150% efficiency (compared to about 40% for other units). For each scfm of compressed air it consumes, the ZL generates an incredible 1.587 scfm of suction flow. The ZL is available with a built-in vacuum switch with digital readout for design flexibility.
Standardized mounting options conform to both ISO 21287 and 6431.Conforms with the ISO 21287 standard, Bore sizes of 20, 25, 32, 40, 50, 63, 80 & 100 mm, Large stroke range from 5 mm up to 150 mm, Construction is similar to the current CQ2 lateral load resistant specification, Snap ring construction allows easy and quicker maintenance, Auto switches can be mounted on any of the four sides
Series CJ2 is auto switch capable Double acting, single rod, end lock cylinder, 16mm bore, Mounting types: basic, axial foot, front flange, double clevis, Standard strokes *: 15, 30, 45, 60, 75, 100, 125, 150, 175, 200, Auto switch capable, Air Cylinder with End Lock, ROUND BODY CYLINDER, 353, 0.021 lb
Standardized mounting options conform to both ISO 21287 and 6431.Conforms with the ISO 21287 standard, Bore sizes of 20, 25, 32, 40, 50, 63, 80 & 100 mm, Large stroke range from 5 mm up to 150 mm, Construction is similar to the current CQ2 lateral load resistant specification, Snap ring construction allows easy and quicker maintenance, Auto switches can be mounted on any of the four sides
Standardized mounting options conform to both ISO 21287 and 6431.Conforms with the ISO 21287 standard, Bore sizes of 20, 25, 32, 40, 50, 63, 80 & 100 mm, Large stroke range from 5 mm up to 150 mm, Construction is similar to the current CQ2 lateral load resistant specification, Snap ring construction allows easy and quicker maintenance, Auto switches can be mounted on any of the four sides
Faster Average speed [mm/s] Measuring conditions Supply pressure: 0.55 MPa 0 50 100 150 125-250 160-300 Bore size-Stroke 200-300 250-450 320-530 Speed adjustment rotary switch set value 0 5 9 Mounting: Vertical downward Load: no-load Operating direction: Upward *1 The average speed value is the stroke divided by the full stroke time.
120 60 10 19 31 55 88 140 251 1 N 12 21 35 61 97 153 268 mm 4 4 6 8 8 12 16 g 66 110 154 300 390 590 1,095 1) 1625 L=20mm 3263 L=30mm 0.5MPa 4 MHSJ3 MHSJ316D MHSJ320D MHSJ325D MHSJ332D MHSJ340D MHSJ350D MHSJ363D MHSJ380D mm 16 20 25 32 40 50 63 80 MPa 0.20.6 0.10.6 -1060 mm 0.01 c.p.m. 120 60 30 9 21 36 62 97 155 280 400 1 N 16 28 47 82 130 204 359 525 mm 4 4 6 8 8 12 16 20 g 95 150
MHY2-10D MHY2-16D MHY2-20D MHY2-25D [mm] 10 16 20 25 [MPa] 0.10.6MPa [] -1060 [mm] 0.2mm [c.p.m] 60 c. p. m [Nm] 0.16 (1.6) 0.54 (5.5) 1.10 (11.2) 2.28 (23.3) (0.5MPa ) 180 ( ) -3 ) g 70 150 320 560 ) 5 2. 2-1. 1. ( ) 2. 3. 2-2. 1. 2.
JMHZ2-16D mm 16 MPa 0.1~0.7 (oC) -10~60 (mm) 0.01 (c.p.m.) 120 32.7 (N) 43.5 mm 10 3 4M40.7 8 3.4 8 2 13 - 4-2.3 V114-5LU (oC) -1050( (ms) ON5 OFF4 Hz 20 / m/s2 150/30 V114-5LU L (L) (V) 24 -1010% (W) 0.4 [0.40.1] P .1367 LED 300 14 - 4-3.
JMHZ2-16D mm 16 MPa 0.1~0.7 (oC) -10~60 (mm) 0.01 (c.p.m.) 120 32.7 (N) 43.5 (mm) 10 (g) 128 3 4M40.7 8 3.4 8 2 11 - 4-2.3 V114-5LU (oC) -1050( (ms) ON5 OFF4 Hz 20 / m/s2 150/30 V114-5LU L (L) (V) 24 -1010% 0.4 (W) [0.40.1] P .1367 LED 300 12 - 4-3.
JMHZ2-16D mm 16 MPa 0.1~0.7 (oC) -10~60 (mm) 0.01 (c.p.m.) 120 32.7 (N) 43.5 (mm) 10 3 4M40.7 8 3.4 8 2 14 - 4-2.3 V114-5LU (oC) -1050( (ms) ON5 OFF4 Hz 20 / m/s2 150/30 V114-5LU L (L) (V) 24 -1010% (W) 0.4 [0.40.1] P .1367 LED 300 15 - 4-3.
C RESET <>ON SVRE ON DRIVE ON (01-099) <> SET OFF DRV C RESET <> 66 - <>12 1 [] A [a ] (01-103) [] C RESET 2 [SW] A [a ] <> <> (01-144) D RESET SVON <> <> <>(M24V) (01-145) D RESET SVON <> <> <> (01-146) D RESET SVON <> 67 - <> <>(DC24V) D RESET SVON (01-147) <> <> <> (01-148) D RESET SVON <> <> (01-149) D RESET SVON <> <> Communicati on error. (01-150
C RESET <> <>1 2 (1-103) C RESET 1 [] A [a ] [] A [a ] 2 [SW] <> <> ( (1-106) RESET SVON ) C <>1 <> <> 1-144 RESET SVON D 73 - <> ON <>(M24V) 1-145 RESET SVON (1) D <> <> <> 1-146 RESET SVON (1) D <> <> <>(C24V) RESET SVON (1) 1-147 D <> <> <> (1-148) RESET SVON (1) D <> 74 - <> 1-149 RESET SVON D <> <> <> *2 LED PLC 11 10: RESET SVON PLC 1-150
A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking, CYL, CLAMP, CLAMP CYLINDER W/LOCK CLKQ, CLK2, 421, 1 lb