Size: 32, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 300mm, Motor Option: B (with Lock), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 8 (8m), Controller Type for (LEC, JXC): AN (LECPA, Pulse Input Type
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: AN (LECPA, NPN, Pulse Input Type), I/O Cable Length for LEC:
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 30mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: AN (LECPA, NPN, Pulse Input Type), I/O Cable Length for LEC: 5
Size: 25, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 30mm, Motor Option: W (with Lock/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: AN (LECPA, NPN, Pulse Input
Size: 16, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: w/o Option, Guide Option: w/o Guide, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): AN (LECPA, Pulse Input Type, NPN), I/O Cable Length
Size: 16, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: B (with Lock), Guide Option: w/o Guide, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type for (LEC, JXC): AN (LECPA, Pulse Input Type, NPN), I/O Cable
Size: 25, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: B (with Lock), Guide Option: w/o Guide, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): AN (LECPA, Pulse Input Type, NPN), I/O Cable
RBQ has a compact design and an interchangeable damper as an option. The RBQ series shock absorbers are available in five sizes and all withstand an impact speed of 3 m/sec.
RBQ has a compact design and an interchangeable damper as an option. The RBQ series shock absorbers are available in five sizes and all withstand an impact speed of 3 m/sec.
There is no oil-free specification for ITV0000 series regulators.
ITV1000 series regulators do not use grease on the parts in contact with fluid.
ITV2000 and ITV3000 series regulators structurally require the use of grease, and therefore cannot be oil-free.
There are some special order products (for the painting industry) in which the grease has been changed to white Vaseline
However, we can perform an inspection to check whether your digital pressure switch is operating within the specification range (and submit an inspection report) if needed.
Contact your local SMC sales office for details.
ZP2 series vacuum pads are available in 38 diameters from 2 to 340mm and offer a variety of pad materials and designs to choose from. The ZP2 series was designed to standardize special products designed for the ZP series. Pad types include miniature pads, compact pads, nozzle pads, multi-bellows pads, sponge pads, mark-free pads, oval pad variations, and heavy-duty pad variations. Nozzle
ZP2 series vacuum pads are available in 38 diameters from 2 to 340mm and offer a variety of pad materials and designs to choose from. The ZP2 series was designed to standardize special products designed for the ZP series. Pad types include miniature pads, compact pads, nozzle pads, multi-bellows pads, sponge pads, mark-free pads, oval pad variations, and heavy-duty pad variations. Nozzle
Please contact us for the latest version.sales@ocaire.com, SILENCER COMPACT 3/8 *LQA, AIRLINE EQUIPMENT, AN SILENCER, EB, AN 3/8INCH STANDARD (PT), .04865 lb
SILENCER, SILENCER AN 2500, 2501, 153, 57.00000 lb
By placing the motor in the axial direction, and reducing the width to 20.5mm and 21mm respectively, both models offer an ideal space saving solution. The LEP series can be adapted for any application with up to 64 positioning points, and positioning repeatability of ± 0.05mm as standard.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
The latest version can be found hereAN20-N02, MUFFLER 1/4 NPT *LQA, AIRLINE EQUIPMENT, AN SILENCER, DD, AN 1/4INCH STANDARD (NPT), .04025 lb
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.