SMC Corporation of America
Elite Part Number Search
Search Results "ZK2Q00K5PCA-08"

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: P (Vacuum Pump System, Single Unit), Valves: J (Supply Valve; N.C., Release Valve; None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: J (Supply Valve; N.C., Release Valve; None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: L2 (L-type Plug Connector Lead Wire w/Connector), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: L2 (L-type Plug Connector Lead Wire w/Connector), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: P (Vacuum Pump System, Single Unit), Valves: J (Supply Valve; N.C., Release Valve; None), Rated Voltage: 6 (12 VDC), Vacuum Sensor: T (Pressure Sensor, -100 to 100, Analog Output 1 to 5 V), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: P (Vacuum Pump System, Single Unit), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: L2 (L-type Plug Connector Lead Wire w/Connector), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: P (Vacuum Pump System, Single Unit), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: L3 (L-type Plug Connector), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

Size: 205 (1/4 Standard), Control Range: FSC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 08 (ø8)

Body, Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Air Operated: Q1 (Air Operated, Supply Valve; N.C; Release Valve: N.C.), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 08 [ø8 One-touch

Body, Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Air Operated: Q1 (Air Operated, Supply Valve; N.C; Release Valve: N.C.), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: N (For Pressure Switch for Vacuum: None; Pressure Sensor Assembly: None), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric

Body, Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Air Operated: Q1 (Air Operated, Supply Valve; N.C; Release Valve: N.C.), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 08 [ø8 One-touch Fitting

Series: KQ2, Model: N (Nipple), Applicable Tubing O.D.: Ø6, Port Size/Applicable Tubing O.D.: Ø8