SMC Corporation of America
Elite Part Number Search
Search Results "ZH18DSA-10-03-12"

3 in the side added with manifold block. 2 stations (10 stations) 3 stations 2. Joint the tie-rod y to increase stations and add manifold block assembly. (Put packing B w on the surface contacting to the end plate.) (11 stations) 4 stations (12 stations) 5 stations 3. For a style with a D-sub connector, open the cover !4 and insert the pin of lead wire assembly !

600 to 750 to 750 50 55 70 80 100 120 7 9 9 9 12 14 10 10 12 12 16 16 32 36 45 50 63 75 141 145 164 164 202 202 64 72 90 100 126 150 FX FZ FT ZZ + Stroke Without air cushion Single clevis type/(C) Bore size (mm) ZZ Z Port Cushion valve 32 40 50, 63 80, 100 160 164 190 238 170.5 175 205 261 CDH10 Single clevis type Bore size (mm) Stroke range H10 CX 0.1 CD L RR U Z ZZ 0.3 32 40 50 63 80

Stations 1 2 3 4 5 6 7 8 9 M SMC 56 28 AXT100-DR-8 110.5 AXT100-DR-10 135.5 SMC SMC K K P P C C U U O O S S L L H H AXT100-DR-12 160.5 11.5 8 AXT100-DR-14 185.5 12 12 3 AXT100-DR-16 210.5 AXT100-DR-19 248 AXT100-DR-21 273 AXT100-DR-23 298 81 16 AXT100-DR-25 323 AXT100-DR-28 360.5 33.5 14 OUT IN OUT IN ARM11BC2-08 Knob position: Bottom L2 L2-10.5 L1=(28 x n)+36 18 28 52.5 39 28 12 12 5.3 3

Note 11) Mass in the dry state without circulating fluids. 88 Thermo-chiller Series HRZ Cooling Capacity HRZ010-WS/010-W1S HRZ010-W2S 12 12 HRZ010-WS/010-W1S HRZ010-W2S 10 10 Cooling capacity (kW) Cooling capacity (kW) 8 8 HRG HRGC HRZ HRW HEC HEB HED Technical Data Related Products 6 6 4 4 2 2 0 20 10 0 10 20 30 40 50 60 70 80 90 Circulating fluid temperature (C) 0 10 20 30 40 50 60 Circulating

Unit 1 Disable Does not generate an error. -10..10 V -5..5 V -10..10 V Selects the analogue input range. (AXB: Cannot select -10..10 V/-5..5 V/ -20..20 mA) -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary. Sign & Magnitude Signed binary.

10 273 262.5 249 12 Stations L1 L2 L3 L4 Stations L1 L2 L3 L4 2 148 137.5 116 16 3 160.5 150 135 13 4 185.5 175 154 16 5 198 187.5 173 12.5 6 223 212.5 192 15.5 7 235.5 225 211 12.5 8 260.5 250 230 15.5 9 273 262.5 249 12 10 298 287.5 268 15 (mm) Stations L1 L2 L3 L4 11 310.5 300 287 12 12 335.5 325 306 15 13 348 337.5 325 11.5 14 373 362.5 344 14.5 15 385.5 375 363 11.5 16 410.5 400 382

2000 2500 3000 1,000 2,000 3,000 Max. speed Vmax (mm/s) Graph 3:40 40 8 10 1/4, 3/8 h=0.7 6 500 30 0.5 40 (3/8) 12 18 24 30 36 1000 1500 2000 2500 3000 3/8 12 3/8 12 3/8 12 3/8 12 3/8 12 0.1 0.3 20 10 Note) Refer to p.4.10-5 for max. absorbed energy since cushioning ability may in some cases exceed the allowable cushioning ability if the cylinder is used under high speeds and large loads

Refer to the table for each pressure specification (page 110) Display/set pressure range Display/min. setting unit Power supply Used as switch output device 12 to 24 VDC (10%), and voltage ripple (p-p) 10% at max. voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Electric spec. Power supply voltage 12 to 24 VDC (10%), and ripple (p-p) 10% at max.

System error (Er0, 4, 6, 8, 40) is displayed. (2) Check if the power supply voltage 6 is in the range 12 to 24 VDC 10%. (2) Supply power in the range "HHH" is 12 to 24 VDC 10%. displayed. (1) Reset applied flow to a (1) Check if the flow exceeds the level within the set flow range.

9 Appendix 9.5.4 Recirculating fluid Pressure Loss Fluid: Water HED003 35 30 Pressure loss kPa 25 HED003-HW13 20 15 10 HED003-HW19 5 0 0 2 4 6 8 10 12 14 16 18 20 Flow rate L/min Fig.9-13 Recirculating fluid Pressure loss (HED003) HED005, HED007 35 30 Pressure loss kPa 25 HED005-HW13 HED007-HW13 20 15 10 HED005-HW19 HED007-HW19 5 0 0 2 4 6 8 10 12 14 16 18 20 Flow rate L/min Fig.9-14 Recirculating

(Default) Spare (SW2-2) Rotary axis setting switch (SW1) Description Display 0 Axis No.1 01 1 Axis No.2 02 2 Axis No.3 03 3 Axis No.4 04 4 Axis No.5 05 5 Axis No.6 06 6 Axis No.7 07 Down 7 Axis No.8 08 (Be sure to set to the 8 Axis No.9 09 "Down" position.) 9 Axis No.10 10 A Axis No.11 11 B Axis No.12 12 C Axis No.13 13 D Axis No.14 14 E Axis No.15 15 F Axis No.16 16 -12- 5.

@ruumoer Axial piping lcentEllzed plplnql Double acting Single rod @12, o1615 to 30 6N, a2g5 lo 50 o32, o40/5 to 1oo o50 lo @10C/10lo 100 Sh9leacting Sp ng retum/extend o l 2 l o o 4 o l 5 . l O o5U1O,m @options High tempeture 1 2 l o 1 0 0 1 2 l o 4 A Low speed (10 lo 50mm/s) l2 to 100 Lovr/ speed cylinder (5 to 5omm/sl 12 to 100 Heal resislanl aulo sw lch 16 to 63 Heavy duty scraper 20

20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 Color: White 3.2 4 6 8 10 D VP VG VP DIN rail AXT100-DRS070 L As for , enter the number from the DIN rail dimensions table.

Table. 5-9 Input data of Pressure value / Channel status module Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Channel status Pressure value 5.2.1. Pressure value of Pressure value / Channel status module Table. 5-10 Pressure value (Pressure range parameter: -100..+200) Bit 110 Pressure value [kPa] 000 h 0.0 NOTE When pressure sensor failure or disconnection, or when the 001 h 0.1 ... ...

Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 2 Analogue input range Sets the analogue input device range. Selects the analogue input range. -10..10 V Channel 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.

The valve element of the C.O. type, which has no return spring, is in an arbitrary position when air is exhausted through the ports 12(P1) and 10(P2). When pressurized air enters the port 12(P1) (exhaust from the port 10(P2)), the valve element opens, and it closes when pressurized air enters the port 10(P2) (exhaust from the port 12(P1)). Component Parts No.

5 10 12 4.5 34.5 Stud bolt part number: MT-S20 Rod end nut part number: NT-015A 11.5 Width across flats 14 With end lock 3 119.5 + Stroke 137.5 + Stroke Basic type With end lock Accessories SMTS20, #1 (#1 + #2) SMTS20, #2 (#2 + #4) SMTS20, #3 7 Precision Cylinder Series MTS Dimensions/25 MTS25 Basic type 12 10 53.5 51.5 2-cushion needle Width across flats 11 7.5 6 Rod cross section 7 6

AS4001F-12 VQC4000 AN400-04 AN400-04 Conditions (With SGP (Stainless steel gas piping)) Direct piping Series CS1 Series MB, CA SGP10A x 1 m AS420-03 AN400-04 VQC4000 Tube x Length Speed controller Silencer 2-2-10 10 For details about certified products conforming to international standards, visit us at www.smcworld.com.

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 CH1 abnormal low tank fluid level 1 CH1 low tank fluid level 2 CH2 Abnormal low tank fluid level 3 CH2 low tank fluid level 4 Reservation 5 Fan failure *1 Alarm flag 1 6 Air exhaust fan failure *2 7 Reservation 8 CH1 abnormal rise of circulating fluid

KPa, kgf/cm2, bar, psi Temp. oC, oF 0 to 2100 L/min 0 to 1050 L/min Instantaneous flow 12 (Displays 0 when the value is below 20 L/min.) (Displays 0 when the value is below 10 L/min.)