SMC Corporation of America
Elite Part Number Search
Search Results "VVX312-08-1"

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 08 (ø8), Seal Method: w/o Sealant, Option: B (None)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 08 (ø8)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: R, Port Size: 01 (1/8), Applicable Tubing O.D.: 08 (ø8)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: R, Port Size: 01 (1/8), Applicable Tubing O.D.: 08 (ø8), Seal Method: S (w/Sealant), Option: Electroless Nickel Plating, Lock Nut Option: J (Round Lock Nut)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: R, Port Size: 02 (1/4), Applicable Tubing O.D.: 08 (ø8), Seal Method: S (w/Sealant), Option: Electroless Nickel Plating, Lock Nut Option: J (Round Lock Nut)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: R (or Metric), Port Size: 02 (1/4), Applicable Tubing O.D.: 08 (ø8), Seal Method: Without Sealant, Option: D (General Environment, Brass Parts, Ni Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: R (or Metric), Port Size: 02 (1/4), Applicable Tubing O.D.: 08 (ø8), Seal Method: Without Sealant, Option: BD (Welding Environment, Brass Parts, No Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 08 (ø8), Seal Method: Without Sealant, Option: D (General Environment, Brass Parts, Ni Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 08 (ø8), Seal Method: Without Sealant, Option: BD (Welding Environment, Brass Parts, No Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 08 (ø8), Seal Method: Without Sealant, Option: BD (Welding Environment, Brass Parts, No Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 08 (ø8), Seal Method: Without Sealant, Option: D (General Environment, Brass Parts, Ni Plating)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 08 (ø8), Sealant: S (with Sealant), Push lock: A (Push-lock)

Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 5μm

Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 20μm

Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 5μm

Max Operating Pressure: 5 (14 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 10μm

Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 20μm

Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 4 (Differential Press. Indicator, Construction 42 Only), Relief Valve: 1 (None), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 10μm

Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 0 (None), Relief Valve: 1 (None), Fluid: 0 (Petroleum), Element: M (Micromesh), Filtration: 10μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)

Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 10μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)