SMC Corporation of America
Elite Part Number Search
Search Results "SRP1101-01"

Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) 48 conversion adapter (Model: ZS-26-D) : The panel mount adapter can be rotated by 90 degrees for mounting. : Front panel of this Controller meets IP65 (if 48 conversion adapter is used, it meets IP40).

Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) 48 conversion adapter (Model: ZS-26-D) 2, Preparation of OUT1 device Prepare the sensor for which OUT1 is to be set. ON OFF Selection of Pressure range, Output style, Response time and Pressure setting method.

Panel mount adapter (Part number: ZS-26-B) Front protective cover (Part number: ZS-26-01) 1: The panel mount adapter can be rotated through 90 degrees for mounting. 2: The panel mount adapter should be fixed firmly with screws. Otherwise, fluids such as water may enter. After contact with the panel, tighten screws by 1/4 to 1/2 turn.

Panel mount adapter (Part number: ZS-26-B) Front protective cover (Part number: ZS-26-01) [F20] Setting of external input Accumulated flow external reset [F22] Setting of analogue output Free range analogue output for instantaneous flow: OFF * Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.

Panel mount adapter (Part number: ZS-26-B) Front protective cover (Part number: ZS-26-01) *1: The panel mount adapter can be rotated through 90 degrees for mounting. *2: The panel mount adapter should be fixed firmly with screws. Otherwise, fluids such as water may enter After the product makes contact with the panel, the screws should be further tightened 1/4 to 1/2 turn.

A B PSE57-01 8 R1/8 PSE57-02 12 R1/4 Lead wire and M12 connector ZS-37-A ZS-37-B -17No.PS-OMS0005-E Adapter with throttle ZS-31-X Model No. D E F G H I ZS-31-X188 20 9 R1/8 Rc1/8 14 1.5 ZS-31-X175 29 13 R1/4 Rc1/4 17 1.6 -18No.PS-OMS0005-E Revision history A: Contents are added. B: Contents are added. C: Contents revised in several places. D: Contents revised in several places.

Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from CCW to CW. Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) 32 - Origin offset The origin offset means the value of the origin.

Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-28No.EX-OMN0011-F (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [

Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-34No.EX-OMO0030-E (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [

A B PSE56-01 8.2 R1/8 PSE56-02 12 R1/4 PSE56-N01 9.2 NPT1/8 PSE56-N02 12.2 NPT1/4 PSE56-A2 PSE56-C01 Rc1/8 PSE56-A2 15.5 URJ1/4 PSE56-B2 9.5 TSJ1/4 PSE56-B2 Adapter with throttle ZS-31-X Model No.

Slave1 Mapping (1600h RPDO Mapping Parameter) 1600h_sub0 = 2 1600h_sub1 = 6320 01 20 (Object 6320h Sub-Index 1, length 32-bit) 1600h_sub2 = 6320 02 20 (Object 6320h Sub-Index 2, length 32-bit) Slave2 Mapping (1600h RPDO Mapping Parameter) 1600h_sub0 = 2 1600h_sub1 = 0007 00 20(Object 0007h (Unsigned 32) Sub-Index 0, length 32-bit) 1600h_sub2 = 6320 01 20(Object 6320h Sub-Index 1, length 32

M3 M5 01 N01 R04 R06 IM5 IM5H M5 female M5 female Port size M3x0.5 M5x0.8 R1/8 NPT1/8 M5x0.8 4 6 thread, thread, through M5x0.8 reducer reducer through type (with type mounting hole) Case Resin case: PBT Fitting: C3604BD PBT Resin case: PBT Resin case: PBT Fitting: SUS303 Fitting: A6063S-T5 Material Pressure sensing section Pressure sensor: Silicon, O-ring: NBR Oil resistance vinyl cabtyre

Front protective cover ZS-27-01 -7No.SFOD-OMO0004-B Summary of Product parts Names of individual parts Output (OUT1) display (Green): Lit when OUT1 is ON. Output (OUT2) display (Red): Lit when OUT2 is ON. LCD display: Displays the current status of charged potential, set mode condition and error code.

How to Order VR2110 01 Port size 01 Rc1/8 N01 NPT1/8 F01 G1/8 10 5. Operation Patterns ON timing: ON upon the set delay Output method: Normal close Settable time delay: 0.5 to 60 seconds Operation time chart is shown in Fig. 1. Time delay (Input signal) Time (Output) Fig. 1: Operation timing chart When an Input Signal Pressure is provided, Output turns ON after the preset time.

Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) 48 conversion adapter (Model: ZS-26-D) : The panel mount adapter can be rotated by 90 degrees for mounting. : Front panel of this Controller meets IP65 (if 48 conversion adapter is used, it meets IP40).

Description Materials Bonnet Aluminum die-cast Nozzle diaphragm assembly Aluminum, Weather resistant NBR Seal HNBR Seal NBR Diaphragm spacer Polyacetal Supply diaphragm Weather resistant NBR Exhaust diaphragm assembly Aluminum, Weather resistant NBR Valve assembly Aluminum, stainless steel, HNBR Body Aluminum die-cast Grease: lithium grease -7- How to order IR 0 0 01 BG A 0 1

AF-OMX0053-B PRODUCT NAME Mist Separator MODEL / Series / Product Number AFM20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AFM30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFM40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFM40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2. Application 8 3. Standard Specifications 8 4. How to Order 9 5.

Rated pressure range A B ZSE3 0 to -101 kPa 0 -101 kPa ISE3L 0 to 98 kPa 0 98 kPa ISE3 0 to 0.98 MPa 0 0.98 MPa -25No.PS-OMO0002-A Dimensions Grommet type Z/ISE3-01/T1-26No.PS-OMO0002-A Connector type Z/ISE3-01/T1-C -27No.PS-OMO0002-A Single-installation type Grommet type ZSE3-0X-28No.PS-OMO0002-A ZSE3-0X--D -29No.PS-OMO0002-A Connector type ZSE3-0X-C -30No.PS-OMO0002-A ZSE3-0X-C-D -31No.PS-OMO0002

DC24V 24VN SY100-82-3-05 DC12V 12VN SY100-82-3-06 AC100V 100VN SY100-82-2-01 AC200V 200VN SY100-82-2-02 2. After removing the holding screw, insert a flat head screwdriver, etc. into the notch on the bottom of the terminal block and pry it open, separating the terminal block and the housing.