SMC Corporation of America
Elite Part Number Search
Search Results "RZQL40-300-120"

Mounting: Both Ends Tapped, Bore Size: 50mm, Thread: NPT Thread, Full Stroke: 300mm, First Stroke: 120mm, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 3 pcs.

Example 2 The stopper ring is mounted on 120 counterclockwise from the standard position shown in Fig. 1-2 of Example 1.

Silicon rubber Urethane rubber Fluororubber 40 161 EPR 39 160 40 50 63 80 100 125 1 0 89 158 2 0 56 156 3 0 55 396 6 0 155 347 12 1 121 345 22 3 120 580 118 531 116 529 How to Order ZPT 40 HB N A14 Mounting thread diameter (Vacuum entry) Pad diameter (mm) Pad diameter Thread dia.

2 e r w 11 Nut Steel (Zinc chromated) M10 x 1 M14 x 1 q 12 Lock ring Aluminum (Clear anodized) Pad diameter: 40, 50 10 to 32 40, 50 120 B Basic/Compact Type Specific Product Precautions Be sure to read this before handling the products. Refer to page 375 for safety instructions. For vacuum equipment and vacuum pad precautions, refer to pages 376 to 379.

Model Flow range 0.5 L/min 2 L/min 5 L/min 10 L/min 20 L/min 50 L/min 100 L/min 200 L/min 0.5 L/min 20 L/min LFE1 0.4 L/min 24 L/min 0.4 L/min 24 L/min 2.5 L/min 100 L/min LFE2 2 L/min 120 L/min 2 L/min 120 L/min 5 L/min 200 L/min LFE3 4 L/min 240 L/min 4 L/min 240 L/min Rated flow range Display flow range Set flow range 21 These safety instructions are intended to prevent hazardous situations

Auto switches marked "O" are produced upon receipt of order. 12-3-8 9 Series MHF2 Low Profile Air Gripper Specifications Air 8: 0.15 to 0.7 MPa 12 to 20: 0.1 to 0.7 MPa 10 to 60C (with no condensation) 0.05mm 120 c.p.m. 120 c.p.m. 60 c.p.m.

30 30 60 0.3 MPa 0.4 MPa 40 0.5 MPa 0.6 MPa 20 20 40 0.6 MPa 20 20 10 10 50 60 10 0 0 20 50 60 10 0 20 30 40 100 120 20 0 20 30 40 100 80 60 40 40 60 80 Gripping point L (mm) Gripping point L (mm) Gripping point L (mm) Gripping point L (mm) Note) Distance to the gripping point L of single acting type is shortened by spring return.

Auto switches marked "O" are produced upon receipt of order. 12-3-8 9 Series MHF2 Low Profile Air Gripper Specifications Air 8: 0.15 to 0.7 MPa 12 to 20: 0.1 to 0.7 MPa 10 to 60C (with no condensation) 0.05mm 120 c.p.m. 120 c.p.m. 60 c.p.m.

30 30 60 0.3 MPa 0.4 MPa 40 0.5 MPa 0.6 MPa 20 20 40 0.6 MPa 20 20 10 10 50 60 10 0 0 20 50 60 10 0 20 30 40 100 120 20 0 20 30 40 100 80 60 40 40 60 80 Gripping point L (mm) Gripping point L (mm) Gripping point L (mm) Gripping point L (mm) Note) Distance to the gripping point L of single acting type is shortened by spring return.

Pressure 0.7MPa 0.6MPa 100 Gripping force N Gripping force N 0.6MPa 60 0.5MPa 80 0.5MPa 0.4MPa 40 60 0.4MPa 0.3MPa 40 0.3MPa 20 0.25MPa 20 0.25MPa 0 20 40 60 80 100 0 20 40 60 80 100 120 Gripping point L mm Gripping point L mm 12-11-9 10 Series MRHQ Rotational Torque and Gripping Point Rotational Torque Graph (3) 3.5 1.0 3.0 0.8 2.5 MRHQ20 MRHQ25 Rotational torque Nm Rotational torque Nm

40 0.3MPa 0.4MPa 0.5MPa 0.6MPa 0.3MPa 0.4MPa 0.5MPa 0.6MPa 20 20 40 0.6MPa 20 20 10 10 50 60 10 0 0 20 50 60 10 0 20 30 40 100 120 20 0 20 30 40 100 80 60 40 40 60 80 Holding point L (mm) Holding point L (mm) Holding point L (mm) Holding point L (mm) Note) Distance to the holding point L of single acting type is shortened end by spring return.

145 170 90 95 100 105 110 115 120 125 130 155 180 95 100 105 110 115 120 125 130 135 160 185 100 105 110 115 120 125 130 135 140 165 190 105 110 115 120 125 130 135 140 145 170 195 15D (M) 10D (M) 20D (M) 15D (M) 25D (M) 20D (M) 30D (M) 25D (M) 10 35D (M) 30D (M) 15.5 40D (M) 35D (M) 45D (M) 40D (M) 50D (M) 45D (M) 75D (M) 50D (M) 100D (M) CHQWB32 5D (M) M10 x 100l x 105l x 110l x 115l x

0.4MPa 0.5MPa 0.6MPa 40 20 20 40 0.6MPa 20 20 10 10 50 60 10 0 0 20 50 60 10 0 20 30 40 100 120 20 0 20 30 40 100 80 60 40 40 60 80 Holding point L mm Holding point L mm Holding point L mm Holding point L mm Note) Distance to the holding point L of single acting type is shorten by spring return.

Features 1, 2 JIS Standard Hydraulic Cylinder Series CH2G/CH2H Bore sizes (mm) Series CHKDB . 1 50 63 80 100 125 160 Series CHKGB . 13 Series CHQB . 25 Series CHM . 45 Series CH2E/CH2F/CH2G/CH2H . 55 Series CHA. 87 Auto Switch Specifications . 115 Hydraulic Cylinder Technical Data Pg. 55 Bore Size Selection . 120 14MPa Nominal pressure Stroke Selection . 123 32, 40, 50, 63, 80, 100 Relationship

140 50 (M) 120 25 (M) x 145l x 145l 145 75 (M) 145 30 (M) 26.5 x 150l x 170l 150 100 (M) 170 35 (M) x 155l 155 40 (M) x 160l 160 45 (M) x 165l 165 50 (M) x 190l 190 75 (M) x 215l 215 100 (M) 16 Compact Hydraulic Cylinder: 16MPa Series CHKGB Construction 32 to 100 Without auto switch 20 to 25 Replacement parts: Seal kits Parts list Kit components Bore size (mm) Seal kit no.

Exhaust Characteristics Flow Rate Characteristics 100 100 100 100 200 200 Vacuum pressure Vacuum pressure Suction flow rate [L/min (ANR)] Air consumption [L/min (ANR)] Suction flow rate [L/min (ANR)] Air consumption [L/min (ANR)] ZK2 80 80 80 80 160 160 Vacuum pressure [kPa] Vacuum pressure [kPa] Vacuum pressure [kPa] Vacuum pressure [kPa] Air consumption Air consumption ZQ 60 60 60 60 120

Entry Vertical ~ _~ Connection Male thread Female thread Vacuum ~2~8 Ms x O.8,M6 x l M4 X O.7,MS X O.8 entry Thread 11O ~16 MS X O.8,M6 x l M5 X O.8,M6 x l ,Ys dia. 120-~32 M6 X l ,M8 x l MsxO.8,M6x I ,M8 x l .2S,Y, -140'1S0 M6 X l ,M8 x l M6 Xl,M8 x 1.25, Va Mounting Use connection for vacuum entry NBR(Black!

YB-03 32, 40 80 9 6.5 10 18 50 d2 d1 YB-05 50, 63 120 11 6.5 12 22 60 L UT C UA (mm) Part No.

Withstand Pressure and Heat Resistance Performance 4.0 3.5 3.0 Pressure (MPa) 2.5 2.0 1.5 1.0 0.5 0 20 40 60 80 100 120 140 160 180 200 Temperature (C) 1/8", 3/16", 1/4", 4, 6 tubing 3/8", 10 tubing 1/2", 12 tubing 3/4", 19, 1" tubing Piping Caution 1. Connect tubing with special tools 2.