Normal output Pressure setting Sets the ON or OFF point of the switch output. -70 kPa(P_1) Hysteresis Set the hysteresis to prevent chattering. 10 kPa(H_1) [F 2] Setting of OUT2 Refer to page 25 Same setting as [F 1] OUT1.
(Removal procedure and ) Applicable message I/O message size Input: Max. 8 byte, Output: Max. 8 byte (Changeable by switch settings) 1 2 Baud rate 125 kbps 250 kbps 500 kbps 500 m or less Thick cable 250 m or less 100 m or less Max. length of Network 3 4 Thin cable 100 m or less 156 m or less 78 m or less 39 m or less Total extended cable length Note: Max. extended cable length is 6 m. 11
Double acting, single rod cylinder; High temperature (XB6) Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, 80, 100; Low temperature (XB7) Bore sizes (mm): 12, 16, 20, 25, 32, 40; Standard stroke range (mm): 5 to 100; Port threads: M (12 to 25 bore); Rc, NPT or G (32 to 100 bore); Low temperature Option (XB7) ambient range -40 to 70°C; High temperature Option (XB6) ambient range -10 to 150
Body sizes: 80, 100; Max. horizontal workload, kg: 75 (size 80); 240 (size 100); Max. vertical workload, kg: 70 (size 80); 200 (size 100); Max. speed, mm/s: 5,000; Max. acceleration / deceleration, mm/s2: 50,000; Stroke range, mm: 300 to 3000 (see catalog for increments); Positioning repeatability, mm: ±0.08
Double acting, single rod cylinder; High temperature (XB6) Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63, 80, 100; Low temperature (XB7) Bore sizes (mm): 12, 16, 20, 25, 32, 40; Standard stroke range (mm): 5 to 100; Port threads: M (12 to 25 bore); Rc, NPT or G (32 to 100 bore); Low temperature Option (XB7) ambient range -40 to 70°C; High temperature Option (XB6) ambient range -10 to 150
Relationship Between Flow Rate and Pressure Difference (Representative values) 100 [Inrush] 90 80 70 60 50 40 30 20 10 0 0 0.05 0.1 0.15 0.2 0.25 Pressure difference [MPa] Flow rate [L/min (ANR)] Rated voltage SX090 [Holding] SX91 1 2 35% (SX090) 42% (SX9 ) of rated voltage 0 V SX92 100 10 ms T1 (ON) (2 s or more) T2 (OFF) Energized condition 1 Low Profile 2/3-Port Solenoid Valve SX90/090
: Standard, Coil Winding Length(m): 100, Applicable Tube Size: Metric Size, Specification: Standard Product, Maximum operating pressure(MPa): 1.6, Operating Temperature(°C): -40 to +100, With Water: 0 to +70 (Do Not Freeze)
, Coil Winding Length(m): 100, Applicable Tube Size: Metric Size, Specification: Standard Product, Maximum operating pressure(MPa): 1.6, Operating Temperature(°C): -40 to +100, With Water: 0 to +70 (Do Not Freeze)
Manifold base Individual port Rc Applicable valve Base weight (g) VVXA311-stations VVXA312-stations VVXA321-stations VVXA322-stations Construction/ Principal Parts Material 1/8 1/4 1/8 1/4 VXA31 5-00 n x 100 + 50 VXA32 5-00 n x 160 + 70 Model/Valve Specifications Av x 10 -6 (m 2) Cv converted C [dm 3/(sbar)] b Cv Oil Air Flow characteristics Max. operating pressure differential (MPa) Orifice
N212 VaY' 3 Port lVFl 10 seies Direct Solenoid Operated o Cv 0.055 (0-100 PSI); 0.05 (0 -150 PSI) Port Size 118" NPTF (Standard) High Speed Response Time 8mSec.
Unique air cushion construction with no cushion ring, Wide size variations from °20 to °100, Nearly three times the allowable kinetic energy, Improved noise reduction * and repeatability, Interchangeable mounting, "Cylinder, 3-POSITION CYLINDER
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No