SMC Corporation of America
Elite Part Number Search
Search Results "RZQF32TN-150-50"

/60 Hz) 4.2 A 10 A 180/200 W 50/60 Hz 220 W 0.01 m (99.9% filtration efficiency) Particles of 0.3 m or more: 3.5 particles/L [ANR] or less Heater operation, PID control Singlephase 200 VAC (50/60 Hz) 2.1 A 5 A Singlephase 230 VAC (50/60 Hz) 2.1 A 5 A Singlephase 100 VAC (50/60 Hz) 9.4 A 15 A Singlephase 200 VAC (50/60 Hz) 4.8 A 10 A Singlephase 230 VAC (50/60 Hz) 4.8 A 10 A Power supply Note

, 75, 100 54 M6 x 1.0 42 12 12(11.8) 45 8.5 M6 x 1.0 7 60 4.5 10 12 34 5.5 9 23 10 49.5 7 30 10 to 50, 75, 100 60.5 M6 x 1.0 48.5 13 16(15.8) 52 8.5 M8 x 1.25 7 69 5 14 12 40 5.5 9 26 10 57 10 40 10 to 50, 75, 100 62 M8 x 1.25 50 13 16(15.8) 64 12 M8 x 1.25 8 86 7 14 12 50 6.6 11 26 14 71 10 Note) Figures in ( ) are the dimensions for applying a wrench.

Note 1) Note 2) Maximum available stroke (mm) Bore size (mm) 20 25 32 40 Standard stroke (mm) Model Long stroke (mm) 1 pc. 201 to 350 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200 D-C7, C8 D-B5, B6 D-H7 D-G5N 10mm 15mm 1500 25, 50, 75, 100, 125, 150, 200, 250, 300 15mm 10mm 20mm 20mm D-B59W D-H7LF Note 1) Intermediate strokes other than the above are produced upon receipt

Standard Strokes Bore size [mm] Standard stroke [mm] *1 20 25, 50, 75, 100, 125, 150, 200, 250, 300 25 32 40 *1 Intermediate strokes not listed above are produced upon receipt of order. The minimum stroke is 25 mm. Mounting Brackets/Part No.

Use a fluid with a kinematic viscosity of 50 mm2/s or less.

Maximum Allowable Load MY3A, MY3B/m1 MY3A, MY3B/m2 MY3A, MY3B/m3 200 50 40 30 100 100 50 40 20 30 50 40 10 20 30 63 63 5 4 20 10 Load weight kg Load weight kg Load weight kg 63 3 40 10 40 5 4 2 3 25 5 4 1 25 40 2 3 25 0.5 0.4 16 2 1 16 0.3 16 1 0.2 0.5 0.1 0.5 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 MY3B max. MY3A max. MY3B max.

Max. operating frequency 10 Hz Lubrication Manual override Non-locking push type Mounting orientation Unrestricted 150/50 m/s2 Impact/Vibration resistance (2) Dustproof Enclosure Grommet, Conduit, Conduit terminal, DIN terminal 100, 200, 110 , 220 , 240 Electrical entry DC AC (50/60 Hz) Coil rated voltage (V) 24, 12 15 to +10% of rated voltage 19 VA (50 Hz), 16 VA (60 Hz) 11 VA (50 Hz),

K M H D Plug Insertion Force in Pressurized Condition MS Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Insertion Force of Series KK T 350 300 VMG 250 Insertion force N Series KK6 200 Series KK4 150 100 Series KK3 Series KK2 50 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

assembly 9 10 19 25 9 10 19 25 Auto switch unit + 2 switches 30 30 50 60 46.5 46.5 30 30 50 60 Angle adjuster 30 47 90 150 203 203 30 47 90 150 49 Series CRB2 Rotary Actuator: Replaceable Shaft A shaft can be replaced with a different shaft type except for standard shaft type (W).

100 150 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] ZFC74 6 ZFC75 8 0.1 MPa 0.3 MPa 0.5 MPa 0.1 MPa 0.3 MPa 30 30 Differential pressure [kPa] Differential pressure [kPa] 0.5 MPa 0.7 MPa 20 20 0.7 MPa 10 10 0 50 100 150 250 200 0 0 0 100 200 300 400 500 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] ZFC76 10 ZFC77 12 0.1 MPa 0.3 MPa 0.1 MPa 0.3 MPa 30 30 0.5 MPa 0.5 MPa 20 20 0.7

Dust-tight, Jet-proof Enclosure: Enclosure: Optional IP65 rating Optional IP65 rating Cylinder operation speed Cylinder bore size mm Valve width mm Cv Rubber seal (Metal seal) Cylinder speed mm/s Individual wiring style 40 50 63 80 100 125 140 150 kit (Connector) C 300 24.5 2.2 (2.0) 450 600 750 Pressure: 0.5MPa, Load rate: 50% Note) Cylinder speed varies according to piping construction

(Refer to Design and Selection on Specific Product Precautions.) 200 VAC (50/60 Hz) J1 J2 Note 1) 3 Note 3) Normally closed None 110 VAC (50/60 Hz) 4 Note 3) Normally open None 220 VAC (50/60 Hz) Q1 Q2 N1 N2 5 6 Latching positive common Normally closed 24 VDC Latching positive common None 12 VDC Latching negative common Normally closed Note 3) CE compliant products are not available for

Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. 16 Series PB1000 Process Pump Built-in Solenoid Valve Type/Air Operated Type Performance Curves/Built-in Solenoid Type/Air Operated Type 1l/min = 0.035SCFM 1MPa = 145psi Cycle 1Hz Cycle 5Hz Cycle 10Hz 70 70 70 60 60 60 50 50 50 40 40 40 Total lifting range m Total lifting

5 to 55 5 to 50 Outlet air atmospheric pressure dew point C Standard performance 20 Inlet air flow rate l/min (ANR) Note 2) 625 62 125 250 375 Outlet air flow rate l/min (ANR) 50 100 200 300 500 Purge air flow rate l/min (ANR) Note 3) 12 25 50 75 125 Inlet air pressure MPa 0.7 Inlet air temperature C 25 25 25 1l/min (ANR) {inlet air pressure at 0.7MPa} Inlet air saturation temperature C

7 PFM (12) 2 (11) 10 0.210(5)L/min 1 25 0.525(12.5)L/min (11) 50 150(25)L/min 11 2100(50)L/min 1( )CO2 A 2 2 S () N 3 M SI4 3 (SI) 4L/min,L A NPN(2) B PNP(2) C NPN(1)+(15V) D NPN(1)+(420mA) E PNP(1)+(15V) F PNP(1)+(420mA) G NPN(1)+5 H PNP(1)+5 5 L 6INOUT () 10 25 50 11 01 Rc1/8 02 Rc1/4 N01 NPT1/8 N02 NPT1/4 F01 G1/8 F02 G1/4 C4 4(5/32") C6 6 C8 8(5/16") N7 1/4 -10No.PF-OMJ0005CN-I

Tightening Torque for Piping Connection thread Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 Rc1 1/2 Rc2 Rc2 1/2 Rc3 Proper tightening torque Nm 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 40 to 42 48 to 50 48 to 50 48 to 50 4. When connecting piping to a product Avoid mistakes regarding the supply port etc. 5.

(50 to 250) Pad diameter (mm) -80 kPa -70 kPa -60 kPa -50 kPa -40 kPa -80 kPa -70 kPa -60 kPa -50 kPa -40 kPa Lifting force (N) Lifting force (N) How to read the graph Example: Workpiece weight 1 kg (Lifting force: 9.8 N) : Conditions/Number of pads: 5 pcs.

Lubrication Dustproof [Degrees of protection 0] (4) VZ Enclosure Shock/Vibration resistance (m/s2) Electrical entry 150/50 (5) Grommet, DlN terminal VT Standard 100, 200 VAC, 50/60 Hz; 24 VDC 220, 110, 48, and 24 VAC (50/60 Hz) 100, 48, and 12 VDC Coil rated voltage VP Option 15 to 10% of rated voltage Allowable voltage fluctuation Coil insulation type VG Class B or equivalent (130C) (6)

From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm). Then, the actuator should move from the position where the pushing operation was completed (where INP turned ON) to a point 50 mm away at 50 mm/s. (Step Data No.2 is used for this operation).

Please contact SMC in this case. 356 Series MGG Guide Cylinder Specifications JIS Symbol Standard Stroke Model (Bearing type) Long stroke (mm) Standard stroke (mm) Bore size (mm) 20 75, 100, 125, 150, 200 250, 300, 350, 400 25 350, 400, 450, 500 32 350, 400, 450, 500, 600 40 350, 400, 450, 500, 600, 700, 800 MGGM(Slide bearing) MGGL(Ball bushing bearing) 75, 100, 125, 150, 200, 250, 300 50