Ambient temperature 25C Ambient temperature 2C 0.5 0.5 Ambient temperature 2C 0 0 15 20 25 Circulating fluid temperature [C] 15 20 25 Circulating fluid temperature [C] HRLE050-W-20 HRLE050-W-20 [50 Hz] [60 Hz] 2 2 Heating capacity [kW] Heating capacity [kW] 1.5 1.5 Facility water temperature 25C, 32C, 40C Facility water temperature 25C, 32C, 40C 1 1 0.5 0.5 0 0 15 20 25 Circulating fluid
Trace the arrow mark, starting with F for cooling temperature 25C (pressure dew point 25C) to find the intersection G on the pressure characteristic line for 0.7 MPa. 8. From the intersection G, trace the arrow mark to obtain the intersection H on the vertical axis. 9. The intersection H is the amount of water included in the compressed air 1 m3 at 0.7 MPa, pressure dew point of 25C.
Safety standards CE marking, UL (NRTL) standards *1 Conditions: Set temperature 25C, Ambient temperature 25C, Circulating flow rate 3 L/min *2 Conditions: Set temperature 25C, Ambient temperature 25C, Circulating flow rate 4 L/min *3 The indicated values are with a stable load without turbulence in the operating conditions.
), 3% F.S. or less (15 to 35C, based on 25C) Note 2) Without lead wire.
Outlet Air at the Atmospheric Pressure Dew point in Compliance with the Tube Length for Discharging the Purged Air (C) Tube length Model Conditions Inlet air temperature : 25C (Saturated) Ambient temperature : 25C Inlet air pressure : 0.7 MPa Outlet air flow rate : Flow gained under conditions of the standard performance. (Refer to page 14-19-16.)
Table 7-1 Water Quality Standards for Fresh Water (Tap Water) Substance Facility water Circulating water spec. spec. pH (25C) 6.5 to 8.2 6.0 to 8.0 Electrical conductivity (25C) (s/cm) *Circulating fluid 1 to 500 100 to 800 0.5 to 300 Chloride ion (mgCl-/L) Max. 200 Max.50 2-/L) Max.200 Max.50 Sulfate ion (mgSO4 Acid consumption (pH4.8) (mgCaCO3/L) Max.100 Max.50 Total hardness (mgCaCO3/L
Note 4) q Ambient temperature: 25C, w Circulating fluid temperature: 20C, e Rated circulating fluid flow rate, r Circulating fluid: Clear water, t Facility water temperature: 25C Note 5) Use a 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temperature is 10C or less.
), 3% F.S. or less (15 to 35C, based on 25C) Note 2) Without lead wire.
), 3% F .S. or less (15 to 35C, based on 25C) Note 2) Without lead wire.
), 3% F.S. or less (15 to 35C, based on 25C) Note 2) Without lead wire.
0 200 400 600 800 1000 1200 1400 Cooling capacity [W] Cooling capacity [W] 25C 25C HED HEA 35C 35C 40C IDH 40C 0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSE018-A-20/23-(T) [50 Hz] [60 Hz] 2000 2000 Ambient temperature Ambient temperature 25C Cooling capacity [W] Cooling capacity [W] 25C 1500 1500 35C 1000 1000 35C 500 500 40C 40C 0 0
(Not including sensor accuracy), Response time: 150 ms or less Current output Note 2) 1.0% F.S. or less 1.5% F.S. or less 2.0% F.S. or less Accuracy (To display value) (25C) 0.5% F .S. 2 digits or less 0.5% F .S. 1 digit or less Display accuracy (Ambient temperature at 25C) Display Indicator light Auto-shift input Note 2) 3 + 1/2 digit, 7 segment indicator, 2-color display (Red/Green), Sampling
Clear Water (as Circulating Fluid) Quality Standard Handling Warning The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Make-up water Standard value 6.8 to 8.0 100 to 300 Item pH (at 25C) Electrical conductivity (25C) Chloride ion (Cl) Sulfuric acid ion (SO42) Acid consumption amount (at pH4.8) Total hardness Calcium hardness
CP96, profile design ISO cylinder with enclosed tie rods, is available in 6 bore sizes from ø32 to ø125mm. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life. Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod. Standard strokes range from 25 to 800mm.Double Acting
CP96, profile design ISO cylinder with enclosed tie rods, is available in 6 bore sizes from ø32 to ø125mm. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life. Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod. Standard strokes range from 25 to 800mm.Double Acting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
CP96, profile design ISO cylinder with enclosed tie rods, is available in 6 bore sizes from ø32 to ø125mm. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life. Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod. Standard strokes range from 25 to 800mm.Double Acting
CP96, profile design ISO cylinder with enclosed tie rods, is available in 6 bore sizes from ø32 to ø125mm. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life. Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod. Standard strokes range from 25 to 800mm.Double Acting
"Cylinder, CP96, TIE ROD CYLINDER W/PROFILE TUBE, N lb
"Cylinder, CP96, TIE ROD CYLINDER W/PROFILE TUBE, N lb