SMC Corporation of America
Elite Part Number Search
Search Results "M-01H-4"

(Color) NBR (Black) Hardness 50 D I M E N S I O N S PA D D I A M E T E R S 2, 4, 6, 8 D I M E N S I O N S PA D D I A M E T E R S 10, 13, 16 F L AT T Y P E F: M5X0.8 F: M6X1 Model A B C Y D E D E ZPR02U 2 2.6 1.2 0.8 ZPR04U 4 4.8 1.6 0.8 20 65.5 25 70.5 ZPR06U 6 7 2.5 0.8 ZPR08U 8 9 2.5 1 A P P L I C A B L E T U B E Applicable Tube OD G H I J 4 4 20.6 15.6 10.4 6 6 21.6 16.68 12.88 F L AT

4, 6, 8 80 + 40 (n 4) 2 n = 4, 8, 12, 16 85 + 40 (n 4) 2 n = 4, 8, 12, 16 90 + 40 (n 4) 2 n = 4, 8, 12, 16 105 + 40 (n 4) 2 95 + 40 (n 4) 2 n = 4, 8, 12, 16 n n = 4, 8, 12, 16 2 (Different sides and same side) 1 10 65 75 80 90 D-Y69/Y7PV D-Y7WV n 90 + 30 (n 4) 2 80 + 30 (n 4) 2 n = 4, 8, 12, 16 10 + 30 (n 2) 2 n = 2, 4, 6, 8 65 + 30 (n 4) 2 n = 4, 8, 12, 16 75 + 30 (n 4) 2 n = 4

Connector C (14.2) Cable length (L) 1 3 5 8 A B C (16.6) (23.7) (6.5) Connector A (12.7) (5.6) 1 3 2 4 1.5 m 3 m 5 m 8 m 3 2 1 (13.5) 1 4 A 1 2 (18) B 10 m (6.5) (14.7) 15 m 15 16 (30.7) (11) L Connector B 20 m (10) Connector D Produced upon receipt of order Connector C terminal no. 1 2 3 Connector A terminal no. 1 2 3 Circuit Cable color U V W Red White Black Connector D terminal no. 12

1 Drain Port 3/4 3/4, 1 D I M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT

D-X Technical Data 315 CG1W Series With Mounting Bracket Axial foot: CG1WLl LH B 15 LT LZ LX 2 LC (Knock pin position) W X Y Z LS + Stroke X M Y W 4 x LD (mm) Bore size Stroke range B LC LD LH LS LT LX LZ M W X Y Z 20 Up to 1500 34 4 6 20 53 3 32 44 3 10 15 7 47 25 Up to 1500 38.5 4 6 22 53 3 36 49 3.5 10 15 7 52 32 Up to 1500 45 4 7 25 53 3 44 58 3.5 10 16 8 53 40 Up to 1500 54.5 4 7 30

Lead wire length Model 24 VDC 100 VAC or less Load voltage 200 VAC 0.5 m D-LC05 Note 4) 50 mA 25 mA Max. load current 12.5 mA 3 m D-LC30 Lead wire length Switch connection side 0.5 m Load connection side 0.5 m 5 m D-LC50 Contact Protection Box Internal Circuit Auto Switch Hysteresis CD-P11 OUT Brown Choke coil Hysteresis is the distance between the position at which piston movement operates

Lead wire length Model 24 VDC 100 VAC or less Load voltage 200 VAC 0.5 m D-LC05 Note 4) 50 mA 25 mA Max. load current 12.5 mA 3 m D-LC30 Lead wire length Switch connection side 0.5 m Load connection side 0.5 m 5 m D-LC50 Contact Protection Box Internal Circuit Auto Switch Hysteresis CD-P11 OUT Brown Choke coil Hysteresis is the distance between the position at which piston movement operates

Lead wire length Model 24 VDC 100 VAC or less Load voltage 200 VAC 0.5 m D-LC05 Note 4) 50 mA 25 mA Max. load current 12.5 mA 3 m D-LC30 Lead wire length Switch connection side 0.5 m Load connection side 0.5 m 5 m D-LC50 Contact Protection Box Internal Circuit Auto Switch Hysteresis CD-P11 OUT Brown Choke coil Hysteresis is the distance between the position at which piston movement operates

S SHP 316L SS 316L SS secondary remelt Hastelloy C-22 Hastelloy C-22 Hastelloy C-22 SH Option Surface finish Specification Standard (Cv: 0.9) High flow (Cv: 1.1) Code Code Ports No code HF Surface finish Ra max 15 in. (0.4 m) Standard 10 in. (0.25 m) 7 in. (0.18 m) 5 in. (0.13 m) No code M V X Ports 2 ports 3 ports 4 ports Code Force compensation (Cv: 0.65) 4)5) 2PW 3PW 4PW FC Pressure gauge

Minimum Auto Switch Mounting Stroke (inch) D-M9, D-F9W D-M9V, D-F9WV No. of auto switches D-A9 D-A9V D-F9BAL Model NCDQ8A(B)-(C)(M) NCDQ8A(B)-100S(M) NCDQ8A(B)-200S(M) NCDQ8A(B)W-(C)(M) NCDQ8A(B)Z-(M) NCDQ8A(B)Z-100S(M) NCDQ8A(B)Z-200S(M) NCDQ8A(B)Z-100T(M) NCDQ8A(B)Z-200T(M) 0.62 (5/8") 0.25 (1/4") 0.62 (5/8") 0.25 (1/4") 1.00 (1") 1 0.62 (5/8") 0.37(3/8") 0.62 (5/8") 0.25 (1/4") 1.00 (1

mm] L1 [mm] L1 [mm] m X 100 100 100 100 0 0 2 4 6 8 10 0 0 2 4 6 8 10 0 0 2 4 6 8 10 0 0 2 4 6 8 10 Work load [kg] Work load [kg] Work load [kg] Work load [kg] Horizontal/Bottom mounting 300 300 300 300 L2 200 200 200 200 L2 [mm] L2 [mm] L2 [mm] L2 [mm] m Y 100 100 100 100 0 0 2 4 6 8 10 0 0 2 4 6 8 10 0 0 2 4 6 8 10 0 0 2 4 6 8 10 Work load [kg] Work load [kg] Work load [kg] Work load [kg

(mm) A Weight (g) L D M Model Soft nylon Urethane KAH23-M5 17 8.5 14 13 2.1 M5 x 0.8 M6 x 1 7 17.5 12.5 8.5 3.4 2.9 4 Applicable tubing 1 8 KAH23-M6 KAH23-U01 8 10 3.2 KAH04-M5 17 M5 x 0.8 M6 x 1 9.5 14 13 2 4 4 8 KAH04-M6 17.5 4 1 8 KAH04-U01 13.5 18.5 5 14 10 10 16 5.6 5.6 K 1 4 KAH04-U02 16.5 10.5 10 KAH06-M5 18.5 M5 x 0.8 M6 x 1 15 14 4 4 11.5 3 10 KAH06-M6 19 Connection

Function 2-Hexagon socket head set screw H4 4/2.5 CJ-5H-4 With a fixed orifice (0.8) H6 6/4 CJ-5H-6 MH4 4/2.5 M-5H-4 Without fixed orifice MH6 6/4 M-5H-6 Dimensions (Dimensions other than below are the same as standard type.)

P Port Vacuum Vacuum Vacuum Pressure side 1.5 2.2 2.2 Orifice size Vacuum side 3 4 4 RA 0.08(1.4) 0.19(3.4) 0.19(3.4) Cv factor (Effective area mm2) AP 0.24(4.3) 0.5(9) 0.5(9) Symbol VXV313m-m-mD VXV313 m-m-m G-B How to Order VXV3 1 3 0 01 1 G Series VX Bracket B None With bracket Vacuum use Solenoid size 1 2 3 No.1 No.2 No.3 Options (Refer to table w in p.4.1-49) S L Z None With surge

) 95 3/5 3/5 2 2 2 2 65.4 41.2 12/14 12/14 60 39 4 4 4 4 30 1 1 43 24.5 D-sub connector cable assembly (25P) AXT100-DS25-015: 1.5 m AXT100-DS25-030: 3.0 m AXT100-DS25-050: 5.0 m 13 17 2n x Rc, G (According to ISO1179-1), NPTF 3/8" 4(A), 2(B) port 33.5 64.5 27 (n-1) x 27 2 x Rc, G (According to ISO1179-1), NPTF 1/2" 1(P) port U side D side n Station number 4 2 1 3 L2 45 L1 98 (n-1) x 27 27

(kg) Load weight m (kg) 30 CXW 30 40 50 32 20 CXS 10 20 CXT 5 4 10 MX 3 5 MXU 200 2 3 4 5 20 30 40 50 10 1 100 1 100 10 200 20 30 40 50 2 3 4 5 Eccentric distance l (mm) Eccentric distance l (mm) MXS 75 to 124 stroke 50 to 74 stroke MXQ 100 100 200 63 P=0.5MPa P=0.5MPa MXF 80 50 40 50 100 MXW 40 Load weight m (kg) Load weight m (kg) 30 40 50 32 MXP 20 30 MG 10 20 MGP 5 4 3 10 MGQ 5 10 100

VG Common Exhaust Type for Main and Pilot VP VZ3 M, VZ5 M 2 4 2 4 Light/Surge Voltage Suppressor Exhaust air from the pilot valve will flow to the main valve exhaust port. For use in an environment in which exhaust from the pilot valve is undesirable. For use when the intrusion of dust from the surroundings must be prevented.

4-16 Side entry Top entry Side entry U0 U1 U2 U3 U0 U1 U2 U3 S0 S1 S2 S3 S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 Without cable Without cable Without cable (2) Max. 16 stations (2) Max. 16 stations (2) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) Max. 16 stations Kit P Kit P Kit J