SMC Corporation of America
Elite Part Number Search
Search Results "LERH10J-R1"

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 3, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: R1 (

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: N (None), Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port: Right Side, With regulator, Round type pressure gauge)

Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit

Distance Range: F (0.01 to 0.03mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: R1

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 3, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: R1 (

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port:

Series: JSY3 (3000 Series), Actuation: 1 (2-position, Single), Manifold Type: 20 (Body Ported), Power Saving Circuit: None, Electrical Entry: L (L Plug Connector w/Lead Wire, 300mm), Cable Length: None, Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size, Thread Piping: R1 (Rc1/16), PE Plate: PE (JSY1: M5, JSY3: Rc1/16

Series: JSY3 (3000 Series), Actuation: 1 (2-position, Single), Manifold Type: 20 (Body Ported), Power Saving Circuit: T (w/Power Saving Circuit), Electrical Entry: L (L Plug Connector w/Lead Wire, 300mm), Cable Length: None, Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size, Thread Piping: R1 (Rc1/16), PE Plate: PE (

Series: JSY3 (3000 Series), Actuation: 2 (2-position, Double), Manifold Type: 20 (Body Ported), Power Saving Circuit: None, Electrical Entry: L (L Plug Connector w/Lead Wire, 300mm), Cable Length: None, Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size, Thread Piping: R1 (Rc1/16), PE Plate: PE (JSY1: M5, JSY3: Rc1/16

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: N (None), Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port: Right Side, With regulator, Round

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: N (None), Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port: Right Side, With regulator, Round

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None), Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port: Right Side, With regulator, Round

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: N (None), Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port: Right Side, With regulator, Round

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port: Right Side, With regulator

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port: Right Side, With regulator, Round type

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port: Right Side, With regulator

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: N (None), Bracket Option: None (DIN Rail Mounting), Control Unit: R1 (w/Control Unit, Supply Port: Right Side, With

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port: Right Side, With regulator, Round type pressure gauge, 0.4 MPa)

Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: Basic Type, Size: 25, Motor Type: Step Motor (Servo/24 VDC), Lead: B (LEFS16, 5mm; LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm), Stroke: 250mm, Motor Option: B (w/Lock), Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 1 (1.5m)

Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: Basic Type, Size: 25, Motor Type: Step Motor (Servo/24 VDC), Lead: B (LEFS16, 5mm; LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm), Stroke: 300mm, Motor Option: B (w/Lock), Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 1 (1.5m)