(DC24 V) 50 () OUT1 () OUT2 () DC(-) () DC(+) IZE112 () PNP2 Max.80 mA 1 V 15 V 1 k () OUT1 () OUT2 () DC(-) () DC(+) IZE113 () PNP2 Max.80 mA 1 V 420 mA 600 (DC24 V) 50 () OUT1 () OUT2 () DC(-) () -13No.IZ*-OMU0031 2 1 1 1 Esd IZE11 nPn NPN PnP PNP 1_5 (15 V) 420 (420 mA) -14No.IZ*-OMU0031 (H_1) () (H1) (H1) (H_1) (H1) (H1) OUT1OUT2OUT1,P_1P_2P1HP2Hn_1n
Output signal: 420 mA (galvanic isolation; 600 V DC) Supply voltage: 1230 V Resolution: 16 bit / 0.244 A Linearity: < 0.05 % FS Temperature effect: < 0.35 % FS External load: max 0780 max 0690 for intrinsically safe CAUTION (ND9000, ND7000): Do not exceed the permitted values!
(mm) 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Weight(kg) 3.15 3.35 3.55 3.75 3.95 4.15 4.35 4.55 4.75 4.95 5.15 5.35 5.55 5.75 5.95 6.15 6.35 6.55 6.75 6.95 0.53 Additional weight for lock(kg) 4 Model LEFS40 Stroke(mm) 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 Weight(kg) 5.37 5.65 5.93 6.21 6.49 6.77 7.15 7.33
Crean class Amount of Type Speed recommended vacuum (mm/s) ISO 14644-1 Fed.Std.209D aspiration 6 1000 10 5 100 20 4 10 30 6 1000 50 5 100 60 4 10 70 6 1000 20 5 100 30 4 10 50 6 1000 30 5 100 70 4 10 90 600 11-LEJS40 1200 600 *Please aspirate it from the port on both sides when aspirating 50/min(ANR). Please select "D" about the type. 11-LEJS63 1200 * Based on SMC test condition.
Analog output Output current: 4 to 20 mA (Rated measurement range) Max. load impedance: 600 (at 24 VDC) Min. load impedance: 50 Current output Accuracy (to display value 25 oC) 1%F.S.
Hysteresis 4 Variable Protection Short circuit protection -66No.PF-OMS0002-B Model PFMC7501 PFMC7102 PFMC7202 Output type Voltage output: 1 to 5 V, Current output: 4 to 20 mA (Refer to analogue output graph) Voltage output Output impedance approx. 1 k Analogue output 5 Impedance Maximum load impedance: 600 at 24 VDC Current output 300 at 12 VDC Minimum load impedance: 50 Response time
900 1200 Installation distance [mm] mm At maximum air flow (air flow scale: 4) 300 mm 300 0 4s 6s 8s 0 2s -300 mm -300 0 300 600 900 1200 Installation distance [mm] mm At minimum air flow (air flow scale: 1) 300 mm 300 6s 0 4s 8s 0 2s -300 mm -300 0 300 600 900 1200 Installation distance [mm] mm 18 - Doc. no.
Load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 -45No.PF-OMO0012-E Specifications Model PF2W7--28--X560 PF2W7--68--X560 PF2W7--29--X560 PF2W7--69--X560 Voltage output (1 to 5 V) Current output (4 to 20 mA) Load impedance Impedance Output impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 Analogue output approx. 1 k Accuracy 5%F.S. max
Internal circuit and wiring example Z/ISE40A(F)Output specification -S/-R (Analogue output mode) Switch output NPN open collector output type-2 output Max. 28 V, 80 mA Residual voltage 1 V or less R: Analogue output 1 to 5 V Output impedance 1 k S: Analogue output 4 to 20 mA Max. load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 Min. load impedance 50 -S/-R (
Residual voltage 1 V or less -P PNP open collector output type Max. 80 mA Residual voltage 1 V or less -S/-R (Analogue output mode) Switch output NPN open collector output type 2 output Max. 28 V, 8 mA Residual voltage 1 V or less R: Analogue output 1 to 5 V Output impedance 1 k S: Analogue output 4 to 20 mA Max. load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600
HRZ001-L HRZ002-L HRZ004-L HRZ001-L1 HRZ002-L1 HRZ004-L1 HRZ001-L2 HRZ002-L2 HRZ004-L2 HRZ008-L2 HRZ001-H HRZ002-H HRZ004-H HRZ008-H HRZ001-H1 HRZ002-H1 HRZ004-H1 HRZ008-H1 HRZ002-W HRZ008-W HRZ002-W1 HRZ008-W1 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX 2min 1min 30s 20s Operating time 10s 5s 2s MIN 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600 700 1000 1500 2000 3000
lead Nil Without cable 8 8m T T-branch type communication plug connector 1 1.5m A 10m T 48mm 3 3m B 15m Number of axis and type of power supply* / C9* 5 5m C 20m 1 1 axisDC24V Produced upon receipt of order (Robotic cable only) When Without controller is selected for controller types, Stroke Standard/Produced upon receipt of order I/O cable length cannot be selected. 100 200 300 400 500 600
25 oC) Operating pressure range 2 Refer to graph of operating pressure and proof pressure Proof pressure 2 Refer to graph of operating pressure and proof pressure Pressure loss Refer to graph of pressure loss Response time 3 1 s Analogue output Voltage output Output voltage: 1 to 5 V, Output impedance: 1 k Current output Current output: 4 to 20 mA Maximum load impedance: 300 for 12 VDC, 600
Max. load impedance: 300 (at power supply voltage of 12 VDC) Load impedance 600 (at power supply voltage of 24 VDC) Min. load impedance: 50 Display 4 digits, 7-segment, dual-colour display (red/green) Display accuracy 2%F.S. 1digit (at ambient temperature 253 C) Indicator LED LED is ON when output is ON OUT1: Green OUT2: Red Enclosure IP40 Environment Ambient temperature range Operation
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer
DATA OUT 1 2 3 SET 1 2 SET MONOSASHI-KUN AC100V OUT1 COM OUT2 COM COM OUT3 Series Guide Series CE1 Bore size (mm) Available stroke range Standard stroke (mm) Series CEP1 Standard stroke (mm) Bore size (mm) 12 equiv. 250 400 500 300 175 200 150 125 100 75 50 100 25 75 50 25 12 25 to 150 20 equiv. 20 25 to 300 32 25 to 400 40 25 to 600 50 25 to 600 63 25 to 600 CEU1 CEU5 Output transistor system
40 P P P P P P P P P 25 to 600 50 P P P 25 to 600 63 P P P 4.4-2 Stroke Reading Cylinder Series CE1 Applications Parts inspection Confirmation of press-fit Measures part dimensions, differentiates between good and defective articles, and prevents the mingling of different parts, etc.
Standard Stroke Maximum stroke available (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.