SMC Corporation of America
Elite Part Number Search
Search Results "ISE20A-T-01"

AU200 AU300 11294-5B113010-5B113010-5B AU100 1 8 01 02 03 Element Bronze w 4 1 C22F C23F C22L C23L Bowl guard Filter Lubricator e 3 8 Accessory Gasket for valve guide 16505 16515 16515 NBR r Option Diaphragm assembiy Weather resistant NBR B G Bracket Pressure gauge with limit indicator 13497A 16517AN 16517AN t Flow direction: Left Right Nil Valve assembly Damper 1349173 13504A 13504A 12293

Refer to gauge guide (P.94). r w q w q Sample Order Number Port 2P 4PL 01 S BP10 e r t 0 4 4 4 4 1 MPA e 2P 4PL qIN wOUT erGauge port (Inlet) Specifications BP1030 15 to 300 psig (0.1 to 2.1 MPa) BP1001 0.5 to 10 psig (0.0034 to 0.07 MPa) BP1002 1 to 30 psig (0.007 to 0.2 MPa) BP1006 2 to 60 psig (0.014 to 0.4 MPa) BP1010 5 to 100 psig (0.034 to 0.7 MPa) BP1020 15 to 200 psig (0.1 to 1.4

Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.

I Shock resistance 100G to X, Y, 2 direction ( 3 times for each direction) Weight 1269 (Incl. 3m-long lead wire) Nolel)eHysleresls mode ZSE When the values 01 PI and P2 are the same or when PI >P2 wlthlll 2digits, the hysteresis will be aulomahcally 2digits for the set value of PI.

Using a T-spacer facilitates the branching of air flow.Features · Attachment for AC Series Air Combination.· Y110-M5-A applicable models: AC10-A, AC10B-A.· Y210-□01-A, 02-A applicable models: AC20-A, AC20B-A, AC20C-A.· Y310-□01-A, 02-A applicable models: AC25-A, AC25B-A, AC25C-A · Y310-□01-A, 02-A applicable models: AC30-A, AC30B-A, AC30C-A.· Y410-□02-A, 03-A applicable models: AC40-A, AC40B-A

Auto shift setting (PSE3 2(T)/3 5(T) models only) 1)Select the display mode of the pressure value at the time of auto shift operation. Either [AS (Auto shift)] or [ASO (Auto shift zero)] can be selected. AS (Auto shift): [AS] displays the differential pressure of the atmosphere and measurement pressure.

Orifice and Port Size Combinations Class Orifice size (mm) Port size 3 2 4 5 7 10 T Conduit terminal 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) 1/4 ( 8A) 3/8 (10A) 4 1/2 (15A) Available types of electrical entry are either G, C and T.

MD0 Automatic/manual selection 10 - (3) Output signal Position control mode: P, Speed control mode: S, Torque control mode: T, Point table method: CP, Program method: CL : Initial setting, : Assignment is available with parameter,: Assignment is not available Symbol Device name P S T CP/ CL Function ALM Trouble This signal turns off while alarm is generated.

D o n o t m a k e a n y a l t e r a t i o n s t o t h i s p r o d u c t . Alterations made to this product may lead to a loss of durability and damage to the product, which can lead to human injury and damage to other equipment and machinery.

Install the ejector body gasket for manifold t into the gasket groove of each ejector assembly r. Install the exhaust block gasket y around the projected part. 2. Install the exhaust block gasket y around the projected part of the end block R w. 3. Install the ejector body gasket for manifold t into the gasket groove of the end block L e. 4.

RLQ MLU Knuckle Pin (Common with double clevis pin) Rod End Nut MLGP ML1C d d Dd9 C m m l L t t H B Material: Rolled steel (mm) Material: Carbon steel (mm) Part No. Applicable cylinder bore size (mm) Applicable cylinder bore size (mm) Applicable retaining ring Part No.

TH Rear cylinder Port TP w e r t q u i y w e r t q u i y Approx. Max. T1 Approx. Max. T1 Approx. Max. T2 Approx. Max. T2 Approx. T3 Cylinder with by-pass piping component parts No. 1 2 3 4 Quantity 1 1 1 1 Description Part No.

7 t !5 r o !8 e !6 w @0 !7 t !5 r o !8 e !6 w @0 !7 t !5 !0 u !2 i q !1 !4 y !9 !0 u !2 i q !1 !4 y !9 !0 u !2 i q !1 !4 y !9 !3 Open Component Parts Component Parts Note No. q Description Material Aluminum alloy Description Material Note No. Body Bushing B Hard anodized Sintered alloy steel o !0 !1 !2 !3 !4 !5 !

How to Find the Flow Rate (At air temperature of 20C) Choke flow: (P2 + 0.1)/(P1 + 0.1) ) 0.5 293 273 + t Q = 120 x S x (P1 + 0.1) x Subsonic flow: when (P2 + 0.1)/(P1 + 0.1) > 0.5 Q = 240 x S x (P1 P2)(P2 + 0.1) x 293 273 + t Q: Air flow rate [ /min (ANR)] S: Effective area (mm2) P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] t: Air temperature [C] Note 1) Formulas above are

Momentary change Pressure Set value P_1 H_1 t (ms) t (ms) Time Switch output operation under normal conditions ON OFF Time Switch output operation when anti-chattering function is on ON OFF Time Pressure range/Unit selection function (F0) Pressure range and displayed units can be switched with this function.

ON OFF IN OUT R 7 Spacer L type bracket Spacer with L type bracket T type bracket Spacer with T type bracket Spacer with L type bracket Spacer with T type bracket T type bracket L type bracket L type bracket Spacer with L type bracket Applicable model T type bracket Spacer with T type bracket Applicable model Applicable model Model Y20T AV2000 B210T Y20L AV2000 AV2000 Y20 B210L Y30T AV3000

Part Number T (UNF) H1 (Hex) H2 (Hex) Thread NPT Wt.

The {T series W (white)} nylon tube can be used for hydraulic piping. Self-aligning fittings can be used for hydraulic piping, but One-touch fittings cannot be used. Make sure that there are no extreme differences in the bore of the pipes used for hydraulic piping. Also check for protrusions or burrs. Prevent air from being drawn into the hydraulic piping.

AFF37B AFF75B Port size N.C. auto-drain N.O. auto-drain Drain guide B 01 B 06 B 1 8 3 4 1B Accessory 02 03 10 14 B 1 4 B 3 8 04 B 1 2 1 4 1 B 1 2 20 2B Option IN-OUT reversal direction -T Element service indicator AFF75A to AFF220A AFF 75A 20 D Accessory (Option) Basic size (Applicable compressor rating) D Auto-drain G Pressure gauge F Companion flange L Anchor bolt 75A 75 kW 125A 110 to

AMH550 AMH650 AMH850 Port size N.C. auto-drain N.O. auto-drain Drain guide 01 B 06 10 14 B 3 4 1B 1 8 Accessory 02 03 B 1 4 B 3 8 04 B 1 2 1 4 B 1 B 1 2 20 2B IN-OUT reversal direction -T Element service indicator Option HA AT ID AMG AFF AM Misc. 14-20-31 3 Series AMH Flow Characteristics/Select the model taking the max. flow capacity into Element oil saturation Initial condition Note)