S: B Throo h hole standard A Both ends ta d L Foot mount F Rod side Iia e Head side flan e Type of Auto Switch , No auto SWitch built in (high magnetic Bore Size D Clevis mount . ~ field resIstance ma net 50 50mm P7G 0P10 63 63mrn l'l14C D-P74 80 80mm i P7 D-P75 Cylinder Stroke D-PS P8!
Operating Pressure Max. operating pressure (MPa) 100C 1.1 0.9 Group Model 20C 2.3 1.7 200C 0.55 0.45 260C 0.3 0.23 2.4 MS Max. operating pressure MPa TILMB01 TILM07 TILM05 TILM11 TILM01 TILM13 TILM19 TILM25 TILM32 A B 2.2 A 2.0 1.8 KKA C B 0.7 1.5 0.35 0.2 1.6 1.4 C D 0.5 1 0.25 0.15 KP 1.2 1.0 F 0.3 0.6 0.15 0.1 0.8 LQ G 0.6 0.2 0.4 0.1 0.05 0.4 0.2 How to Order MQR 0.0 20 0 20 40 60 80
Minimum strokes for mounting of auto switches 40 50 63 Number of auto switches mounted Auto switch type Auto switch models 60 2 pcs. (same side) Reed switch D-Z73, Z76, Z80 20 1 pc., 2 pcs. (different sides) 60 2 pcs. (same side) D-Y59A (B), Y69A (B) Y7P (V) 20 1 pc., 2 pcs. (different sides) 70 2 pcs. (same side) D-Y7NW (V), Y7PW (V) Solid state switch Y7BW (V) 1 pc., 2 pcs.
(Tolerance 30%) 47 Series NCA1 Medium Duty Air Cylinder Specifications D-F5 W/D-J59W (With indicator light) PLC: Programmable Logic Controller Grommet D-F5PW D-F59W D-J59W Auto switch model number The suitable operating point can be indicated with a green light.
B 150 0400 A XC9 Bore size Auto switch Adjustment range A: 0 to 1" B: 0 to 2" Mounting Adjustable StrokeReturn Stroke Dimensions P + Stroke LF + Stroke (2) EE (NPTF) 4-DD D across flats AA D across flats 4-NT Depth ND d + Adjustable range SN + Stroke ZZ + Stroke + Adjustable range Bore size (in) MM KK A AA B C D DD E EA EE G J JA K R WF Y LF P ZZ TN XT SN d mm 150 (1.5") 5/8 7/16-20 3/4
Note) Lead wire length symbols: 0.5 m Nil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z CS1 C76 C85 C95 CP95 NCM NCA D-X 20Data 6-15-7 7 Series NCA1 Basic Style: NCA1B (MX0 mounting style) ZB + Stroke P + Stroke D across flats 4-DD 2-EE (NPTF) AA KK EA MM BA B A C R WF G J E LF + Stroke Bore size (in) MM KK A AA B BA C D DD E EA EE G J R WF Y LF P ZB 150 (1.5") 5/8 7/16-20 3/
System construction status No.0 No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 End EX600 EX600 EX600 EX600 EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -SEN3 plate -LAB1 -LAB1 -LBB1 -LBB1 -127No.EX-OMX1011 (6) When unit diagnostics is generated, the diagnostic information is displayed on the [SYSTEM CONFIGURATION STATUS] screen.
D The air in the cylinder initially opens the piston valve and the check valve and discharges rapidly through the switching valve. The fully opened piston valve closes as shown in Fig. D when the pressure in the cylinder is lower than the set pressure. Then the air passes through the check valve and becomes discharged (Fig. D).
(N) and (P+) (N-)) of the main circuit converter is displayed. 0900 V 62 - 6.
type 1 2 3 4 5 6 7 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 to 120 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Nil F N Rc (PT) G (PF) NPT Manual override Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Nil A B Other Electrical entry Light/Surge voltage suppressor G E T D DO Grommet Grommet terminal Conduit terminal DIN terminal
How to Order VFN212 02 N 5 F D Z CE marking NAMUR Interface Nil Q CE marked product Voltage Thread type 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz Nil Rc (PT) F G (PF) N NPT Electrical entry Solenoid G Grommet E Grommet terminal T Conduit terminal D DIN terminal Nil Single solenoid D Double solenoid Manual
D-859W D-B53, D-A53 0-A64. D-864 surgeabsolber D.A54, D-854, D-A44(C), D-A34(C) D-467 Feed switch D-A33(C) Solid State Type Internal Circuit D-F59, D-G59, D-G39(C) D-FsPW D-GsPW o Lalch typ d agnos s oinput Biue o D-FsP, D-GsP D.FsBAL, D.GsBAL, D-K59W, D-J59W D-F5NTL, D-GsNTL @ D-J59, D-K59, D-K39(C) ffit*' iffil.
Model r e b m u N A f o t r o P l e d o M g n i t r o P e z i s t r o P B e z i s t r o P A c i r t e M " 2 3 / 5 " 4 " 4 / 1 " 6 " 6 1 / 5 " 8 t r o P A t r o P B h c n I 1 1 M K h c u o t e n O g n i t t i f g n i t t i f h c u o t e n O 0 1 , 6 6 1 / 5 8 8 / 3 0 1 2 / 1 2 1 2 1 M K h c u o t e n O g n i t t i f d a e r h t T P N 0 1 , 6 4 / 1 T P N ) T P ( c R 4 / 1 d a e r h
400W/60 Electric specification Motor type AC servo motor (AC100/200V) Motor type S2,S3,S4: Incremental 17bit encoder (Resolution: 131072 p/rev) Motor type T6,T7,T8: Absolute 22bit encoder Resolution: 4194304 p/revFor LECSB2-T, LECSS2-T Encoder Note7) Motor type T6,T7,T8: Absolute 18bit encoder (Resolution: 262144 p/revFor LECSC2-T Max. 725 Power [W] Note5) Max. 445 Max. 1275 Type Note6)
i d i P P PV)SV SV MV , , ,SEL IDH Series 37 3.10 IDX-OM-W038 3. / 3.10.3 IDH*4-*** IDH*6-*** SV 25.0 25.0 AT oFF oFF oFF / P 5.0 9.0 :% I 60 70 : D 11.5 13.5 : LoC oFF oFF oFF A1TP 10 10 AL1 5 5 A1HY 1 1 DLY1 20 20 : 3.10.4 LoC (028) oFF () ALL PARA SV [] .
Setting range: 0.1/0.2/0.5/1/2/5/10/30/60 s (Initial value 1 s) : The analogue input update time can also be set for every wireless slave unit. Refer to "(A) Slave unit setting" (page 38). Analogue output update time -26No.EX-OMV0017 (D) Slave unit registration Registration for wireless communication between the wireless master unit and the wireless slave unit.
DC: DL (With indicator light) Option Grommet G D DIN terminal 5 Base mounted 0 Manifold 4 Coil rated voltage 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 5 9 24 VDC Construction Other Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Body ported De-energized Base mounted
Hz 230 VAC 50/60 Hz 191 Thermo-chiller Basic Type HRSE Series Circulating Fluid Temperature Controller Simple function and performance Cooling capacity 1.2, 1.6, 2.2 kW (60 Hz) Power supply 100/200 VAC (50/60 Hz) 230 VAC (50/60 Hz) Triple control Compressor, fan and electronic control valve can be controlled depending on the heat load from the user s equipment.
(Resin or rolled steel) LVariation Standard stroke (mm) Bore size (mm) Series Mounting Action Rod end configuration Standard variation Built-in magnet Locking Cancel cap Proximity switch Option 15 20 30 40 20 32 50 63 80 P P P P P P P P P P P P P P P P P P P P P P P P P Double acting Lever style Double acting with spring RSH Flange Adjustable Single acting 4.3-1 Heavy Duty Stopper Cylinder
20 P=20 19.5 1 23 9 Station D side 50 29.5 Cover diameter 1.4 75.5 300 3.8 Cross sectional area 0.2mm2 (Lead wire length) 64 62 11.5 29.5 34 The broken line indicate DIN rail mounted type [-D].