SMC Corporation of America
Elite Part Number Search
Search Results "EX260-SMJ4"

[Please Refer to the Following Pages of the Catalog]· P. 22 EX500 (Gateway distribution system 2 (128 points) compatible)· P. 27 EX500 (Gateway distribution system (64 points) compatible)· P. 36 EX250 Integrated type (input/output compatible)· P. 42 EX600 Series compatible· P. 52 EX260 Integrated type (output compatible)· P. 58 EX126 Integrated type (output compatible)· P. 64 EX120 integrated

Tie rod base EX260 type manifold for SV2000 valves ; Serial wiring, integrated-type for output ; Maximum 16 stations available as standard ; Optional DIN rail mount ; 6 port sizes available

Base mount EX260 type plug-in manifold for VQC2000 valves ; DeviceNet™, PROFIBUS DP, CC-Link, Ether CAT and PROFINET fieldbus protocols ; Maximum 12 stations available as standard ; Optional DIN rail mount

Tie rod base EX260 type manifold for SV3000 valves ; Serial wiring, integrated-type for output ; Maximum 16 stations available as standard ; Optional DIN rail mount ; 6 port sizes available

Base mount EX260 type plug-in manifold for VQC4000 valves; DeviceNet™, PROFIBUS DP, CC-Link, Ether CAT and PROFINET fieldbus protocols; Maximum 12 stations available as standard

Base mount EX260 type plug-in manifold for VQC1000 valves ; DeviceNet™, PROFIBUS DP, CC-Link, Ether CAT and PROFINET fieldbus protocols ; Maximum 12 stations available as standard ; Optional DIN rail mount

Tie rod base EX260 type manifold for SV1000 valves ; Serial wiring, integrated-type for output ; Maximum 16 stations available as standard ; Optional DIN rail mount ; 6 port sizes available

Base mount EX260 type plug-in manifold for VQC5000 valves ; DeviceNet™, PROFIBUS DP, CC-Link, Ether CAT and PROFINET fieldbus protocols ; Maximum 12 stations available as standard

Available protocols include PROFIBUS-DP®, DeviceNet™, CC-Link, Ethernet I/P™ and EtherCAT®, PROFINET, POWELINK and CC-Link IE Field™ Protection class: M12: IP67 and RJ45: IP20; EX250, EX260, EX500, EX600; Length: 1m, 2m, 3m, 5m, 10m

JSY plug-in type is compatible with fieldbus, ethernet and wireless communication module such as EX600 and EX260. Plug-in type flow rate (Cv): JSY1000: 0.27; JSY3000: 0.70; JSY5000: 1.65; Valve body width: JSY1000: 6.4mm; JSY3000: 10mm; JSY5000: 15mm; IP67 protection rating (JSY1000: IP40)

JSY plug-in type is compatible with fieldbus, ethernet and wireless communication module such as EX600 and EX260. Plug-in type flow rate (Cv): JSY1000: 0.27; Valve body width: JSY1000: 6.4mm; IP67 protection rating (JSY1000: IP40)

JSY plug-in type is compatible with fieldbus, ethernet and wireless communication module such as EX260 and EX120. Plug-in type flow rate (Cv): JSY1000: 0.27; JSY3000: 0.70; Valve body width: JSY1000: 6.4mm; JSY3000: 10mm; IP67 protection rating (JSY1000: IP40)

Vacuum capable manifold; New EX260-PEC1 specifically made for JSY-E; Available up to 24 stations of single solenoid or 12 with double; Optional built-in pressure sensor

JSY plug-in type is compatible with fieldbus, ethernet and wireless communication module such as EX600 and EX260. Plug-in type flow rate (Cv): JSY1000: 0.27; JSY3000: 0.70; JSY5000: 1.65; Valve body width: JSY1000: 6.4mm; JSY3000: 10mm; JSY5000: 15mm; IP67 protection rating (JSY1000: IP40)

Available protocols include PROFIBUS-DP®, DeviceNet™, CC-Link, Ethernet I/P™ and EtherCAT®, PROFINET, POWELINK and CC-Link IE Field™ Protection class: M12: IP67 and RJ45: IP20; EX250, EX260, EX500, EX600; Length: 1m, 2m, 3m, 5m, 10m