SMC Corporation of America
Elite Part Number Search
Search Results "CXSM32TN-45"

Specification: 22 (Copper, Fluorine & Silicon-free + Low Particle Generation, Vacuum Suction Type), Bearing Type: M (Slide Bearing), Bore Size: 32mm, Port Type: TN (NPT: 25 & 32mm Bore), Stroke: 20mm

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure(

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure(

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure(

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure(

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure(

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 90, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure(

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber bumper at both ends, Specification: Clean Series (vacuum type), Port

IO-Link master unit (EX600-LAB1): 44 byte occupied Output date: (Unit 3) IO-Link maser unit (EX600-LBB1): 44 byte occupied Output date: (Unit 4) SI unit (EX600-SEN7): 4 byte occupied When Diagnostic mode 0 Input data Output data Byte 0 DXB (Unit 0) Input 0 to 7 Byte 0 DYB (Unit 1) Output 0 to 7 Byte 1 Byte 1 LAB1 (Unit 2) Process data : : LAB1 (Unit 2) Process data Byte 44 Byte 44 Byte 45

PF3A703H (For 3000 L/min) PF3A706H (For 6000 L/min) PF3A712H (For 12000 L/min) -95No.PF-OMX0002-B Dimensions Symbol Models A B D E F H K L N PF3A703H 130 45 79.1 55.3 22.5 25 35 60 30 4 x M4 x 0.7 depth 7 PF3A706H 170 60 94.1 70.3 30 68 45 80 40 4 x M5 x 0.8 depth 8 PF3A712H 200 70 104.1 80.3 35 85 50 100 50 4 x M6 x 1.0 depth 9 -96No.PF-OMX0002-B Lead wire with M12 connector (ZS-37-A) Pin

-62No.PF-OMW0004-B Integrated display type (straight type): PF3WC (mm) Flow range (L/min) a 0.5 to 4 (symbol 04) 40 2 to 16 (symbol 20) 40 5 to 40 (symbol 40) 45 -63No.PF-OMW0004-B Remote sensor type (supply type): PF3WS (mm) A B Flow range a (L/min) Open Close Open Close 0.5 to 4 (symbol 04) 33 14 33 14 40 2 to 16 (symbol 20) 33 14 33 14 40 5 to 40 (symbol 40) 33 14 33 14 45 -64No.PF-OMW0004

[oC]) PD = (Pr b) / a = [45 0] / 0.1 = 450 -76No.PF-OMV0006-B IO-Link parameter setting IODD file IODD (I/O Device Description) is a definition file which provides all properties and parameters required for establishing functions and communication of the device.

Weight*11 kg 45 *1 Use the product in conditions where freezing will not occur.

Operation Instructions . 45 .. Outline of operation command . 45 .. Positioning operation . 45 .. Reset . 48 . Operation Examples . 49 .. Positioning operation . 49 Operation Mechanism. 50 . Positioning operation . 50 . Return to the origin . 51 . Response time in receiving an electric actuator input signal 52 1 - . Methods of interrupting operation . 52 Alarm detection . 53 .

Operation Instructions . 45 .. Outline of operation command . 45 .. Positioning operation . 45 .. Pushing operation . 48 .. Reset . 51 . Operation Examples . 52 .. Positioning operation . 52 .. Pushing operation . 53 Operation Mechanism.54 1 - . Positioning operation . 54 . Pushing operation . 54 . Return to the origin . 56 .

Power supply connector . 42 6.1 Connector specifications . 42 (1) Motor drive power connector : M PWR . 42 (2) Control power supply connector: CI . 42 6.2 Wiring . 43 (1) Wiring of the power supply connector. 43 (2) Wiring of the stop switch . 43 (3) Wiring of the lock release . 44 6.3 Wiring of shutdown circuit . 45 (1) Stop (Stop switch) . 45 (2) Stop (Stop relay contact) . 45 (3) Motor

CN1 CN2 RJ-45 LEC-CAP-X22 27 - No a) RJ45 8P TM21P-88P HIROSE b) M12 4pin HR24-8DJ4PE550A(73) HIROSE XS2G-D4 [] c) M12 4pin HR24-8DP4S300(73) HIROSE XS2C-D4 [] 28 - 82 CN1 CN1 (LEC) 120 1/4W OV CN1 No.

degC Fig. 6-1 Cooling capacity 2) Heating capacity Fluid: water Fluid: water 1000 2000 900 Ambient 35C 1800 Ambient 30C 800 1600 Ambient 25C Heating capacity W Heating capacity W 700 1400 600 Ambient 20C 1200 500 Ambient 15C 1000 400 800 300 Ambient 15C 600 200 400 100 0 200 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 Circulating fluid temperature degC Fluid temperature degC Fig