SMC Corporation of America
Elite Part Number Search
Search Results "CLSD250TN-800-D"

I/O cable length [m] None 1.5 3 5 Nil 1 3 5 Driver mounting Nil D Screw mounting DIN rail mounting Pulse input usable only with differential. Only 1.5 m cables usable with open collector.

Current models and models scheduled for release in 1999 include; ECC-PNAL-6MR-A, ECC-PNAL-10MR-A, ECC-PNAL-10MR-D, ECC-PNAL-10MT-D, ECC-PNAL-20MR-A, ECCPNAL-20MR-D, and ECC-PNAL-20MT-D. 1.1.2 Product Conguration Check the contents of the ECC-PNAL-PCS/WIN-E box against this list to conrm that the following accessories are supplied.

Push-locking slotted type [D] Disconnection To remove the socket from the connector, pull out lead wire while depressing the hook of the socket with a fine screwdriver. If the socket is to be re-used, reposition the hook again. Caution Gently operate locking manual override types B, D using a small screw driver.

4 60 PSI (4kg|/cm') 6 90 PSI (6kglicm") lnput Current 0-4-20mADC(standard) . l 1 5 m A D C ' 2 2 1 0 m A D C ' 3 5 2 5 m A D C *4 10 50 mADC ' Special Order o ,,' Ogeration'/ Construction Model MmOO(Lever type) Single acting, Normal operation When the input current increass, the armature witt be subjected to a clockwise torque, pushing the flapper lever to the teft.

North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics lnc. (Milwaukee) SMC Pneumatics lnc. (Richmond) SMC Pneumatics Inc. (Cleveland) 2305 East Aurora Rd., Unit A-3 Twinsburg, OH 44087 Tel: (330) 963-2727 FAX: (330) 963-2730 SMC Pneumatics Inc.

Throttle/Manual lock of 2 port solenoid valve Stations Nil C W M Without throttle, without manual lock With throttle, without manual lock Without throttle, with manual lock With throttle, with manual lock 1 2 3 4 5 6 1 station 2 stations 3 stations 4 stations 5 stations 6 stations Throttle Option Nil B Without bracket With bracket With mounting bracket for DIN rail Manual lock D Note) DIN

mm Model Port size A B C D E F G H J K L M N P Q R IDF55E 800 (868) IDF75E 900 (968) 36 50 526 (250) 5195 13 500 75 7001 R2 470 855 (128) (455) (110) IDF Series 6-3 Dimentions 6 2 IDX-OM-W025 Air Dryer 6 References 6-4 Electrical Circuit IDF22E-20, IDF37E-20 IDF22E-30, IDF37E-30 GFCI For Option R For Option R GFCI L1 L3 L2 PE TB N PE L TB PRR ILS THR ILS MC MC PRR MC THR CM C01 MC OLP1

: inch (mm) 10mm N 3/8 B Q E D A G C F 1 J 31.5 [820] P L K M N H (L=2800) IDFB4E/6E/8E/11E-11 1. : inch (mm) 10mm N 3/8 A B E D Q G C F 1 J 31.5[800] H N M 4-0.5 (L=2800) [4-13] 6-3 6 3 IDFB Series IDX-OM-W020 6 IDFB15E-11 1. : inch (mm) 10mm N 3/8 E D B A Q G C F (820) K L P N M H J 4-13 (L=2800) (inch [mm]) A B C D E F G H J K L M N P Q IDFB3E 3/8 8.9 16.1 18.6

SIZE PORT SIZE B G H D E WITH LAMP SWITCH DRAFT AIR OUTLET THERMOMETER EVAPORATION BALL VALVE BLOCK TERMINAL AUTO DRAIN F C VENTILATION VENTILATION [DIA.911]) (WIRE DIA.0.4 ENTRY HOLE POWER CORD DRAIN TUBE LENGTH39.4[1000] J N M K L P [4XDIA.13] 4XDIA.0.5 (SIZE OF RECOMMENDED BOLTM10) A B C D E F G H J K L M N P Q R Model Port Size Dimensions (inch [mm] ) 31.5 [800] 34.2 [868] IDFB55E 2 1.4

(M10) Unitinch [mm] A B C D E F G H J K L M N P Q R 31.5 34.2 IDFB55E 2 1.4 [800] [868] 18.5 33.7 5.0 17.9 4.3 9.8 2 0.5 19.70.1 3.0 27.60.04 20.7 20.40.2 [470] [855] [128] [455] [110] [250] [50] [13] [5002] [75] [7001] [526] [5195] [36] 35.4 38.1 IDFB75E 2 [900] [968] IDFB Series 6-3 6-2 IDX-OM-W035 6 6-4 IDFB22E-11 IDFB22E/37E-23 R GFCI GFCI R GFCI R GFCI L N PE R TB1 PE N L 1 2 TB1

0 q CONTROLLER PRESSURE OUT w Position Detection Switch Flow Sensor Pressure Control Pressure Sensor e w r RUN 4 3 2 1 CH kPa 4 3 2 1 SW t e y D-IN RUN UP SET P-ON DOWN STOP READ r u i o t y u i o !

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-17 Connection of RS-232C HRS090 Series 3.3Installation 3-27 HRX-OMT002 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.

VCHR 12 2 1 2 1 2 1 1 ITV 2 1 2 1 2 1 2 1 2 1 L 2 2 1 L L L IC AFM AF ARP AFM AF ARP 10 ITVX c Control a clamping force by precise pressure control. d Release residual pressure with the backflow function. Residual pressure circuit Also exhausts residual pressure completely. Sensitivity within 0.2% F.S. allows more precise pressure adjustment. Repeatability within 1% F.S.

SRF 12 2 1 2 1 2 1 1 ITV 2 1 2 1 2 1 2 1 2 1 L 2 2 1 L L L IC AFM AF ARP AFM AF ARP 10 ITVH c Control a clamping force by precise pressure control. d Release residual pressure with the backflow function. Residual pressure circuit Also exhausts residual pressure completely. Sensitivity within 0.2% F.S. allows more precise pressure adjustment. Repeatability within 1% F.S.

SUP. 3 1 2 3 1 2 3 1 2 E Padlock mounting position D C SUP J 2 2 x K A T IN OUT AA 3 L 2 x P1 (Port size) B V BB U Built-in silencer (Option) M (Width across flats) 3 N P2 (Port size) Q EXH Y Bracket (Option) R S X W Dimensions (mm) Standard specifications Model P1 P2 A B C D E F G H I J K L M 1/8, 1/4 1/4, 3/8 1/8 1/4 3/8 1/2 1/2 66.4 80.3 104.9 110.4 134.3 22.3 29.4 38.5 42 53 40 53 70

Before Use Fieldbus device EX250-SCA1A : Output numbers are assigned to stations from side D to U of manifold in order. (Refer to manual of each valve manifold for the directions of side D and U). : Standard manifold is wired in double. Output numbers are assigned to side A and B alternatively. In case of single solenoid valve, output on side B is free.

Closing the valve for initial pumping and the valve for main pumping When the initial and main pumping solenoid valves are de-energized, the valve S and M will return and start sealing. 9 XL-OMM0005-A 5 Dimensions 57.6 XLDV-25 (For AC) 55.4 (For DC) 2.2 8.5 C E B 1(P) D (KF flange) Fn G M5 1(P) SUP A M5 3(R) EXE H A XLDV-40160 C C E B 8.5 8.5 5.5 D (KF flange) Fd (K flange) M5 G Fn 1(P) SUP

Printed in Japan. 1st printing November, 1999 D-SMC.L.A. P-80 (YG)

L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover