SMC Corporation of America
Elite Part Number Search
Search Results "CDLG1BA20TN-50-P-M9PSAPC-C"

No power supply required Range of operating conditions Inlet air pressure (MPa) 0.3 to 0.85 0.3 to 1.0 5 to 50 5 to 55 Inlet air temperature (C) Note 1) 5 to 55 Ambient temperature (C) Outlet air atmospheric pressure dew point (C) 5 to 50 Standard performance 20 Inlet air flow rate (L/min (ANR)) Note 2) 625 62 125 250 375 Standard performance conditions Outlet air flow rate (L/min (ANR))

Arntient and tluid temperatureMax .120'F(Max. 50'C) Respon time 2 poitl'| slngle/doubb 20ms or less at 75 PSI (skg/cm'?) 3 pcition 40ms or less at 75 PSI (skgf/cm'?)

is normally pressurized, and the valve opens when the solenoid valve is turned ON and closes when it is turned OFF. 10 XL-OMV0019 5-2.Dimensions C (KF flange) (K flange) Fd Fn C J Port 1(P) S K L M N B T Port 3(R) A G A Unit: mm Model A B C Fn Fd G J XLFV-16-2 40 108 38 30 17 41 XLFV-25-2 50 121 48 40 26 46 XLFV-40-2 65 171 66 55 41 54.5 XLFV-50-2 70 185 79 75 52 71 XLFV-63-2 88 212 100

Dimensions [mm] Model A B C D E F G H J K L M N P Q R S T U V W Weight [g]*1 Outer body dia.

([ 1_P]) Normal output [ 500] 500 L/min (PF3A701H) [ P] ([P_1 ]) Select input switch operation [1000] 1000 L/min (PF3A702H) [F 1] [ 50] 50 L/min (PF3A701H) [ H] ([H_1 ]) Setting of Hysteresis [ 100] 100 L/min (PF3A702H) ([dt1 ]) Delay time setting ([0.00]) 0.00 s [CoL ] Select display colour [ SoG] ([1SoG]) Green when ON Red when OFF (OUT1) [oUt2] Select output mode [ HYS] Hysteresis mode

CP A1 D N 50 3 0 0 ' H TOptions sertes --r-l Cushions Both Ends WithoutCushions Cushion FrontEnd Cushion RearEnd Rod Boot (Nylon)(Max. Temp.140'F (60"C)) Rod Boot (Rubber) (l\rax. Temp. 230"F (1 10'C) ) Stroke Min. = 1" (25mm) Max. :12"(300mm) Others Consult Factory 'When ordering stroke should be in mm not inches. Boi (ln.

base SS073A01 02Stations C V100 SY L2 0.1 W with power saving circuit SYJ L1 1.8 18 5 23.5 21 P = 7.2 11 22 3.5 3.5 VK 8 VZ R1.7 7 25.5 3.4 28.5 VT 3.5 150 (Lead wire AWG#26) 27 VP 5 150 (Lead wire AWG#26) ~ = VG 3.5 VP ~ = ~ = S070 6 barb fitting 1 (SUP) port n U side 1 2 3 4 5 D side VQ 6 barb fitting 3 (EXH) port VKF (18) 12 VQZ 7 3.5 5 5 3.2 3.5 VZ P = 7.2 12.8 n-3.2, 4 barb fitting 2

MLU Clevis pin and knuckle pin Rod end nut ML1C D30 d Dd9 -X d 20D C l m m t t L H B Data (mm) (mm) Part no. Size 25 32 40 50 l 18.2 22.2 26.2 32.2 d 7.6 9.6 9.6 13.4 L 23 27 31 38 d M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 D 16.5 18 21 26 Dd9 C 19.6 21.9 25.4 31.2 B 17 19 22 27 H 6 7 8 11 Size 25 32 40 50 Part no.

Dimensions Meter-out type Meter-in type F E D B A C J G K H L B Model A MIN. MAX. MIN. MAX.

kPa Electrical Power supply voltage 12 to 24 VDC (10%), and power supply ripple (p-p) 10% at max. spec.

(mm) Dimensions G H J K A B C D E F L M N P Q R V Model LVD1m-Sm LVD2m-Sm LVD3m-Sm LVD4m-Sm LVD5m-Sm 4 20 20 45 39 9.5 46 23 11.5 4.5 11 30 5 21 28 22.5 M5 x 0.8 (5/32") 30 30 54.4 56 11 67 28.5 13 4 20 44 7 23 31.5 17 M5 x 0.8 6 35 35 79.5 62 17.5 83 45.5 14.5 6 22 50 7 37 36 21 M5 x 0.8 6 35 35 82 62 20 93 48 14.5 6 22 50 7 39 36 21 M5 x 0.8 6 8 76 25 17.5 45 45 105.5 114 65 32 64 7 52

90 256 1 for L5 255 1 for L3 General purpose input no., State AND input time out subroutine call command C-AND (P-no.) label General purpose input no., State OR input time out subroutine call command C-OR (P-no.) label General purpose input no., State AND input condition jump command J-AND (P-no.) label Condition jump General purpose input no., State OR input condition jump command J-OR

) NPT Nil F N Voltage Manual override/Classification C F H J P V Y Z 9 1 2 3 4 5 6 7 8 A B 115 VAC, 50/60 Hz 32 VAC, 50/60 Hz 42 VAC, 50/60 Hz 230 VAC, 50/60 Hz 100 VDC 6 VDC 48 VDC 110 VDC Other voltages 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz 48 VAC, 50/60 Hz 12 VAC, 50/60 Hz 24 VAC, 50/60 Hz Electrical entry Non-locking

TF G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/4 NPT 1/4 Nil M3 x 0.5 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 1/4 12-CY3B6 12-CY3B10 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 12-CY3B50 12-CY3B63 25 30 35 50 50 50 60 60 70 10 16 19 25 30 40 40 60 70 16 16 78 81 103 132 137 156 182 180 192 d C H B H 4 4 8 8 10 B 8 14 26 32 41 C 9.2 16.2

LVM205R Universal 3 Features 3 Series LVM Power consumption (C) (W) Flow characteristics Fluid temperature Volume of valve chamber Weight (g) Page Water Av Cv Air C b P.1 to 3 0.43 x 106 0.018 0.06 0.2 18 20 2 2.5 at inrush P.4 to 8 0.04 0.13 0.22 11 30 0.96 x 106 1 at holding 0.03 0.1 0.2 20 34 0.72 x 106 1.5 P.4 to 10 0 to 50 (with no condensation) 0.72 x 106 0.03 0.1 0.2 20 34 1.5 5.5

when the solenoid valve is turned ON and closes when it is turned OFF. 10 XL-OMV0016 5-2.Dimensions C (KF flange) (K flange) Fd Fn C J Port 1(P) S K L M N B T Port 3(R) A G A Unit: mm Model A B C Fn Fd G J XLAV-16-2 40 108 38 30 17 41 XLAV-25-2 50 121 48 40 26 46 XLAV-40-2 65 171 66 55 41 54.5 XLAV-50-2 70 185 79 75 52 61 XLAV-63-2 88 212 100 87 95 70 80.5 XLAV-80-2 90 257 117 114 110 83

u t o s w i t c h A u t o s w i t c h s p e c i f i c a t i o n A u t o s w i t c h i n s t a l l a t i o n A u t o s w i t c h s e t p o s i t i o n I n t e r n a l s t r u c t u r e a n d o p e r a t i o n p r i n c i p l e C u s h i o n s M a i n t e n a n c e I n s p e c t i o n P e r i o d i c i n s p e c t i o n D i sassem ble and reassem bl e C a u t i o n o f d i

0.011 0.021 0.011 0.011 0.006 A B C D E Note) 0.35 0.5 0.1 (With power saving circuit) F Note) Note) An option only applicable to 24 VDC plug lead type. 4-11-12 13 Series S070 3 Port Solenoid Valve Compact Direct Operated Dimensions Body ported stacking type manifold SS073M01 02Stations C 3.8 3.4 P = 7.2 7.7 3.4 6.8 8.3 V100 6 barb fitting 3 (EXH) port SY n-3.2, 4 barb fitting 2 (OUT) port

The fluid and ambient temperatures should be -5 to 50 C. Operation under low temperature (5 C or less) leads to cause damage or operation failure due to frozen moist in the fluid or air. Protection against freezing is necessary. Air dryer is recommended for elimination of drain and water. Avoid sudden temperature change even within specified temperature.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com d n i n i W g c e t i r o i d n e p a t e p i P Leakage Voltage It must be noted that when connecting C-R element parallel to switching element, leakage current flows through C-R element and the leak voltage increases