AF-OMR0020-C PRODUCT NAME MIST SEPARATOR MODEL / Series / Product Number AFM20-(F,N)01(F,N)02(B,C)(-2,6,C,J,R,Z)-A AFM30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,R,W,Z)-A AFM40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,R,W,Z)-A AFM40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-A Contents Page 1. SAFETY INSTRUCTIONS 1-5 2. APPLICATION 6 3. SPECIFICATIONS 6 4. HOW TO ORDER 7 5. OPTIONAL BRACKET ASSEMBLY 8 6.

3-Rc 3 8 3 8 Rc 1 8 VNH1 -10A VNH2 -15A VNH3 -20A VNH4 -25A A B A B A B A B 60 80 100 115 235.5 265 300 319.5 60 77 96 113 46 60 76 85 34 40 50 60 24 36 41 50 135 164.5 200 219 50 60 79 90 77 95.5 111 119 1 2 3-Rc 3 4 3-Rc1 Rc1 4 Rc1 4 Rc1 8 1 2 2-Rc 3 4 2-Rc1 Model J K L M N O P Q R S T U V VNH1 -10A A B VNH2 -15A A B VNH3 -20A A B VNH4 -25A A B M5 x 0.8 depth 5.5 M6 x 1 depth 6 M8 x 1.25

B Contact output signal 3 selected alarm Sets the alarm selected for the contact output signal 3.

No5.Countor plug No6.Controller setting software 120.3 120.3 No1.Card Motor mm mm 200 200 Separately sold product mm/s mm/s No2.Actuator 100 500 100 500 1 1 200 1000 200 1000 2 2 cable 50 200 50 200 3 3 Prepared by the user No7.Controller setting cable Power Communication cable PC supply Power supply (LEC-W2A-C) (prepared by the cable 24 VDC user) USB cable (LEC-W2-U) for the

1MPa: Approx. 10.2kgf/cm2 0.2MPa 0.2MPa 100 100 0.1MPa 0.1MPa 0 0 20 20 40 40 60 60 Gripping point L mm Gripping point L mm MHS2-63D MHS2-63D Note: 1N = 0.2248lbf 1in = 25.4mm 1MPa = 145psi Pressure 0.6MPa Pressure 0.6MPa 600 600 Gripping force N 0.5MPa 0.5MPa Gripping force N 0.4MPa 0.4MPa 400 400 0.3MPa 0.3MPa 0.2MPa 0.2MPa 200 200 0.1MPa 0.1MPa 0 0 20 20 40 40 60 60 Gripping point L mm

Applicable cable O.D. 6 to 8 (D, DZ) P Pg9 J (DIN terminal: D, DZ) I (Grommet: G) F (Air operated) Pilot port 12 (P1) 2 x (Back side 10 (P2)) 4 x M 8 1 Manual override (Non-locking push type) P1 D S Q E 15 B A H (DIN terminal: D, DZ) G (Grommet: G) A R B C Main port 1 (A) (Back side 2 (B)) Port side: refer to table below Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S VNB2V

Optuon B ventilation air outlet Earth leakage breaker Handle Lid for circulating fluid fill port (There is a handle on the other side too.)

How to determine the auto switch installation position MHZ2 Step 2) Insert auto switch into the switch installation groove from direction B. "Set up as directed with power connected under no pressure or low pressure." A B MHZJ2 MHQ Step 3) Slide the auto switch in the direction of the arrow until the light illuminates.

It can cause damage or air leakage. 100 8 7 to 9 150 1/8 14 12 to 14 200 1/4 17 22 to 24 200 3/8 21 28 to 30 200 1/2 24 Lock Nut Tightening Torque Caution 1. Suitable screw torque for a hexagon lock nut is shown in the table below. For standard installation, turn 15 to 30 using tool, after fastening by hand. Pay attention not to over torque the product.

(mm) 20 200 25 250 30 300 35 350 LMV20/Without air blow circuit T0806 (8 x 6) Applicable tubing Symbol Length T0425 (4 x 2.5) Applicable tubing Air adjusting needle for mist T0604 (6 x 4) Applicable tubing Oil adjusting needle Mixing valve (LMV20-) LMV201 L 46 (24) Double pipe nozzle AIR OIL D C B 12 E A 24 9.5 2 3 57(Max.) 12.5 AIR SMC 27.5 4 10 40 23.5 OIL L Dimension (mm) 20 200 25 250

Without brake C section details Cross section BB l\rodel D F L 1 5 4 231 LXPB B-50 L X P B B . 7 5 173 256 52 L X P B _ B _ 1 0 0 204 281 246 323 LXPB B -.125 L X P B B 1 5 0 271 348 120 90 L X P B _ B _ 1 7 5 296 373 LXPB_B_-200 321 394 ?$rc zs S8[i8$ [10 Camraclnectl' 0i|llomiom $lift $crExi tlE LXPB S With brake I I shows the localion at which origin point swiich operates.

degrees setting Solid state (12 to 24 VDC) 6 For manifold, individual SUP 2 point setting/without analog output/3 rotation setting 2 point setting/without analog output /200 degrees setting Silencer 1 point setting/analog output/3 rotation setting Nil S High noise reduction type Standard type E19 1 point setting/analog output/200 degrees setting M21 M15 1 point setting/without analog output

AW-OMX0057-A PRODUCT NAME Filter Regulator MODEL / Series / Product Number AW20(K)-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AW30(K)-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW40(K)-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW40(K)-(F,N)06(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW60(K)-(F,N)06(F,N)10(B,C,

Accessory Function plate for VO307 (D sealing, with thread): DXT152-14-5A 628 A VNH Series High Pressure Coolant Valve 3.5 MPa, 7.0 MPa Specifications 3 port valve 2 port valve A B Model A B VNH211 -15A A B VNH311 -20A A B VNH411 -25A A B VNH113 -10A A B VNH213 -15A A B VNH313 -20A A B VNH413 -25A A B VNH133 -10A A B VNH233 -15A A B VNH333 -20A A B VNH433 -25A VNH111 -10A Operating fluid

XMA series with KF (NW) flange A (mm) Model Weight (kg) Conductance (L/s) B (mm) CYV XMA-16 40 103 0.33 5 XMA-25 XMA-40 XMA-50 50 113 0.61 14 B 65 158 1.40 45 70 170 2.00 80 A 160 XMA-63 XMA-80 88 196 3.60 90 235 6.20 200 A : Common to all series. 479 Series Variations Operating pressure Flange size Shaft seal system Models Valve type Angle type In-line type Options Application Switch Indicator

B to Nominal filtration accuracy of 5, 10, 25, 50, 100 m can be selected.

Normally open Grommet, Conduit, DIN terminal, Other (Option) VNB01V VNB02V Grommet, Grommet terminal, Conduit terminal, DIN terminal Electrical entry 10 (P2) 12 (P1) Air operated Coil rated voltage (V) AC (50/60 Hz) 100 V, 200 V, other voltage (Option) 24 V, other voltage (Option) 15% to +10% of rated voltage Class B or equivalent (130C) DC 2 (B) 1 (A) 2 (B) 1 (A) Allowable voltage fluctuation

9 @2 Piston rod B-side piston Rod cover Piston rod B-side piston Rod cover Parts List: Standard Piping No. Description Material No.

R C R C (44) G1/2 E A H 2-P Port size B (S) E G1/2 2-M Thread depth N D A H B 2-P Port size 2-M Thread depth N D L L K K N.O.