(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9NV, Lead
3 q u t y u o A !9 r e @0 !0 !2 !5 !6 !4 i A w A-A Component Parts No. Description Material Note No.
Devise a system that ensures safety so that if a person engages the emergency stop, or if a safety device is tripped during a system malfunction such as a power outage, the halting of the machine will not cause the movement of the rotary actuator to pose a hazard to humans or damage the equipment. 4.
Be certain to adopt a reliable connecting method if the rotary actuator is used very frequently or if it is used in a location that is exposed to a large amount of vibration. 5. There may be cases in which a speed reduction circuit or a shock absorber is required.
For the angle adjusting type, angle adjusting screws are mounted to the left cover. of e g k n e ra y w n a io y Angle adjusting screw Angle adjusting screw at 1 ot 8 0 n R io ct e r di g in st u dj n A o a n ti g c e e l e gl ir d a n d g A j u n s ti ti s n u g j d a d ir e e R R l g c 0 0 n ti ot ot o A 8 8 n 1 1 at at y y io io a a n n w w r r y y a a e e n n k k g g of of e e Angle
Recommended pneumatic circuit for the CKQG/P series The following is an example of a basic meter-out control circuit for operating a cylinder using an air filter, a regulator, a solenoid valve and a speed controller. 7) It is possible to use the pneumatic circuit shown below. However, unlock the cylinder before operating.
When using a stopper cylinder for intermediate stopping of a load connected directly to a cylinder, etc. The operating ranges shown in this catalog apply only for stopping of a pallet on a conveyor. When using a stopper cylinder to stop a load connected directly to a cylinder, etc., the cylinder thrust will become a lateral load.
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
Extention cable A dimension M L Z I/O cable Note 1) 1000 Note 2) 15.5 (500) 5 5 2 x M5 depth 8 44 3000 60 42 60 (A) 5000 2 x for M4 thread Note 2) Note 1) For the 3-point stoppable type, the I/O cable is a 9-core type and for the 5-point stoppable type, a 11-core type is used.
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
Note 2) Since the table is made of a magnetic substance, it could become magnetized if touched by a magnet, etc.
Traveling parallelism: The amount of deflection on a dial gauge when the table travels a full stroke with the body secured on a reference base surface.
Please contact SMC when the AC welding current exceeds 16000 A.
Even if a proper plier (tool for installing C-type retaining ring) is used, it is likely to inflict damage to a human body or peripheral equipment, as a retaining ring may be flown out of the tip of a plier (tool for installing C-type retaining ring). Be much careful with the popping of a retaining ring.
Width: Max. 62% reduction (in comparison with SMC CA2 cylinder) Bottom mounting Side mounting Axial mounting (mm) A Dimension Comparison A Size Reduction rate MU CA2 24 28 32 39 50 60% 60% 62% 62% 57% 25 32 40 50 63 60 70 85 102 116 A (MU) A (CA2) Various brackets are available to accommodate a wide range of applications. Can be mounted with short pitch.
Use the table as a guideline for mounting. MDHR2-20, 30 MDHR2-10, 15 H H L L Auto switches of D-M9NV, D-M9PV, D-M9BV, and D-M9AV are used. Auto switches of D-M9N, D-M9P, D-M9B, and D-M9A are used. Auto switches of D-M9NV, D-M9PV, D-M9BV, and D-M9AV are used. Max. Protrusion of Auto Switch from Edge of Body: L, H Max.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.