Size: 40 (1/2), Thread: F (G), Port Size: 04 (1/2), Accessory: B (Bracket), Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF)
Size: 40 (1/2), Thread: F (G), Port Size: 06 (3/4), Accessory: B (Bracket), Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF)
Size: 40 (1/2), Thread: M Thread, Rc(PT), Port Size: 06 (3/4), Accessory: B (Bracket), Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF)
Size: 40 (1/2), Thread: F (G), Port Size: 06 (3/4), Accessory: None, Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF)
Otherwise, chattering will occur. 10: The flow rate given in the specification is the value at standard condition (STD). 11: This is only available for models with the units selection function. 12: Displayable range change based on the setting of zero cut-off function. 13: Set the time for digital filter to the sensor input.
B C d H MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M NTJ-015A NT-015A NT-02 NT-03 NT-04 10 8 9.2 6 15.5 5 10 9.2 M5 x 0.8 4 20.5 8 16 8 9.2 8 16.5 6 16 11.5 M6 x 1.0 5 22.5 10 20 8 9.2 10 18.5 6 20 15 M8 x 1.25 5 24.5 13 25 10 11.5 12 22.5 11 25 19.6 M10 x 1.25 6 33.5 17 28 14 16 16 28.5 12 28 25.4 M14 x 1.5 8 40.5 22 Applicable bore (mm) Part no.
B H NTJ-015A NT-02 NT-04 NT-05 M5 x 0.8 7.8 9.2 12 8 4 H B M8 x 1.25 12.5 15.0 20 13 5 M14 x 1.5 21.0 25.4 32, 40 22 8 M18 x 1.5 26 31.2 50, 63 27 11 Electrical Wiring Input/Output The input/output of the scale cylinder is performed by a 7 shielded twisted pair wire from the sensor section plus a connector.
NT-02 NT-03 NT-04 Applicable bore size 20 25, 32 40 13 15.0 12.5 M8 x 1.25 5 LF LE LY LG 17 19.6 16.5 M10 x 1.25 6 LD 22 25.4 21.0 M14 x 1.5 8 Applicable bore size LH LR LC LD LE LF LG Part no. L Mounting Nut (mm) CM-E020B CM-E032B 20, 25 32, 40 30 10 8 6.8 22 15 30 24.5 Material: Iron 40 13 10 9 25 15 40 34 d Applicable bore size Part no. Included pin part no.
PDF239-E Series NCA1 Air Cylinder NFPA Interchangeable Large Bore Size Features Medium duty 5", 6" and 8" bores 11 different NFPA mounting options Standard with adjustable air cushion Auto switch capable Series NCA1 Cylinder Large Bore Contents page How to order Auto Switches Specifications Construction Replacement Kits 3 3 4 5 5 Mounting styles 6 6 7 7 8 8 9 9 10 10 11 B MX0 basic style
Body material/Port size/Orifice diameter Symbol Body material Port size Orifice diameter A Bronze (CAC) 3/8 11 B 1/2 14 C 3/4 18 D Stainless steel 316L equivalent Pressure type Nil Standard H High pressure 3/8 11 E 1/2 14 F 3/4 18 Other Special Options Special Entry for Pilot Port/ Insulating Adapter Type VXB215 XCA Enter standard product number.
CN1 CN2 Shuts off 3 12 13 9 10 7 8 20 17 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG P5 19 OP 4 11 LG V+ 1 P5 LG MR MRR MD MDR SD 20 12 7 6 SG P5 LG MR MRR MD MDR SHD P5 LG MR MRR MD MDR SHD 7 8 1 2 4 5 9 7 8 1 2 4 9 Detector 17 16 Plate 5 (Note 2) 11 15 14 2 12 (Note 6) Connect the shielding wire securely to the ground plate inside the connector.
Fluid Nil No L Yes Thread type*1 5 Steam Nil Rc A G B NPT Body material/Port size/Orifice diameter Symbol Body material Port size Orifice diameter A Bronze (CAC) *1 The thread type for the main piping and pilot piping is the same. 3/8 11 B 1/2 14 C 3/4 18 D Stainless steel 316L equivalent Pressure type 3/8 11 E 1/2 14 F 3/4 18 Nil Standard H High pressure Other Special Options Special Entry
0.5 M4 x 0.7 7 35 + Stroke 35 + Stroke 7 Standard type: MQQT CC 40 + Stroke 8.5 13 to 17 M5 x 0.8 M6 x 1 45 + Stroke 9 RB 7.5 50 + Stroke 8 to 11 M3 x 0.5 65 + Stroke M4 x 0.7 7 J Anti-lateral load type: MQQL (Built-in ball bushing type) 70 + Stroke 5.5 80 + Stroke 8 13 to 17 M5 x 0.8 M6 x 1 D6.5 85 + Stroke 105 + Stroke 7 -X : Stroke 20Data 10-5-11 11 Series MQQ Dimensions Basic style (Through-hole
Model AM850 AM250 AM350 AM450 AM550 AM650 AM150 Rated flow (l/min (ANR)) 750 1500 2200 3500 6000 12000 300 (1) Port size (Nominal size B) 1/8 ,1/4 ,3/8 1/4 ,3/8 ,1/2 3/8 ,1/2 ,3/4 1/2 ,3/4 ,1 3/4 , 1 1, 11/2 11/2 , 2 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note 1) Max. flow capacity at a pressure of 0.7MPa. It varies depending on operating pressure.
AFF Port size 3/4B 1/8B 01 02 03 06 10 14 AMl 1B 1/4B Note) Please refer to p.4.7-7 about "How to Order" case assembly. 3/8B 11/2B Related products 2B 20 04 1/2B Option combinations Available Not available D J R AMG150 AMG250 AMG350 AMG450 Applicable model Accessories Options C C D J R Accessories/Optional specification AMG550 AMG650 AMG850 Symbol N.C. auto drain N.O. auto drain Drain guide
1 2 B 11 2B B 20 2B B Options Precautions Be sure to read before handling.
Rod cover Tolerance h9 Clean room series Series 10-, 11-CUJ Two auto switches can be installed even for 4mm strokes.
2 12 Mount with this surface up FLUID OUT Rc, NPT, G 1/8 84 72 60 41 7.5 45 2 x 4.5 Mounting hole Manual override pin 66 16 16 Foot (Option) 3 2 x M4 x 0.7 Female mounting threads Thread depth 6 12 Silencer: AN120-M5 (Option) 8 AIR SUP Rc, NPT, G 1/8 16 Lead wire length: Approx. 570 mm FLUID IN Rc, NPT, G 1/8 8 18 12 11 11 AIR EXH M5 x 0.8 Thread depth 8 Air Operated PB1013A 18 1.5 10 Mount
2ywr e 11 Stainless steel 304 Thread 12 PVC Lead wire !
Refer to "Auto Switch Mounting Strokes for 8" on page 11. Refer to the standard stroke table on page 2. Rod end configuration End lock Nil R Without end lock With rear end lock Nil M Rod end female threads Rod end male threads Applicable auto switches/Refer to pages 14 through 18 for detailed auto switch specifications.