SMC Corporation of America
Elite Part Number Search
Search Results "55-JSXFAF-14N-B"

A B A B 54 MXY6 34 59 5 MXY8 MX 39 67 MXY12 MTS 47 MY Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside (mm) B B CY Model Mounting Switch operating range A B A B A B 50 MXY6 2 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 38 55 MXY8 2.5

(ZS-46-B) +(ZS-46-D) 90 -17No.PS-OMU0008CN-D <> AB (ZS-35-B) +(ZS-35-E) B A -18No.PS-OMU0008CN-D 812 Nm -19No.PS-OMU0008CN-D () TU0425( 4 2.5) -20No.PS-OMU0008CN-D FG () () No.

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -37No.PS-OMY0007-A [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.

For pipe fitting 4B through 6B Applicable fittings For pipe fitting 3/4B through 3B Welding Welding Piping B Reducing tees B 1 1 x 1 x 1 24 or more 11/4 11/2 11/4 x 11/4 x 1 1B socket 11/2 x 11/2 x 1 cut in half 2 x 2 x 1 2 21/2 x 21/2 x 1 21/2 3 x 3 x 1 3 Pipe 4B through 6B Reducing tees B Socket Pipe : JIS B 2301 : JIS B 2302 : JIS B 3452 Without flash 16-12-8 Paddle Style Flow Switch Series

LEH Time LEY -X5 A (LEPY10L) B 11LEFS Set value of pushing force [%] Duty ratio [%] Continuous pushing time [minute] 11LEJS Duty ratio = A/B x 100 [%] 70 or less 100 25A80 70 10 100 50 5 50 LEC * [Set value of pushing force] is one of the step data input to the controller. * [Continuous pushing time] is the time that the actuator can continuously

Note 2) 400 V type is provided with an earth leakage breaker -B as standard.

Auto Switch Proper Mounting Position (mm) A B C D Auto switch model D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 36.5 41.5 56.5 67 67 83.5 92.5 D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 17.5 17.5 17.5 18 18 19.5 18.5 D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 24.5 29.5 44.5 55 55 71.5 80.5 D-A9 D-A9V K dimension (Switch rail height) Bore

Calculation: (Example 1) MUB40-15S(T) Basic weight 0.62 kg RQ (Example 2) MUC50-5S(T) Basic weight 1.06 Additional weight (Mounting bracket) 0.40 1.06 + 0.40 = 1.46 kg MU Construction DSpring return -X B 20Data B section MU25 Spring extend B A A section MU25 Component Parts No. q w e r t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !

Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.

B operation Contact output signal 3 Sets alarm which is selected for contact output 3.

With lock/226) 28 (64) Stroke 39 (4) 21 Motor cable (6) 70 58 47 6.7 17.5 Vacuum port Rc1/8 Note 3) 35 Encoder cable (7) Lock cable (4.5) Motor option B: With lock 8H9 ( ) depth 6 +0.036 0 13 n x 6.8 B 30 8H9 ( ) depth 6 +0.036 0 140 200 E C x 200 (= D) 25 Note 1) Please consult with SMC for adjusting the Z-phase detecting position at the stroke end of the end side.

Calculation: (Example 1) MUB40-15S(T) Basic weight 0.62 kg RQ (Example 2) MUC50-5S(T) Basic weight 1.06 Additional weight (Mounting bracket) 0.40 1.06 + 0.40 = 1.46 kg MU Construction DSpring return -X B 20Data B section MU25 Spring extend B A A section MU25 Component Parts No. q w e r t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !

(Part1:General requirements) ISO 10218-1992:Manipulating industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1:-((1 :) JIS B 8433-1993: 2) : : : 1 2. 3. 1. 2. 3. 4.

Set value x 1 B RATE switch B RATE The transmission rate of controller IF CC-Link communication speed F Do not use D C 10Mbps B 5Mbps 230.4 A 2.5Mbps 625kbps 156kbps Do not use 10Mbps 5Mbps 115.2 2.5Mbps 625kbps 156kbps Do not set B RATE to the value of "Unused" 16 - Caution1: Set the controller IF communication speed at 115.2kbps to use the teaching box (LEC-T1-).

55 25 Rc 1/4 (EXH port) 36 36 82.6 (IN, OUT port) 2-Rc 3/4, 1, 1 1/4 When B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be positioned at left, when looking at the EXH port in the front face.

B Switch output 1(2) Released ON Work 1 Work 2 Work n Atmosphere OFF ZSE ISE Formula for Obtaining the Set-Value A B Switch output response time when autoshift is input.

Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.

W A A A B (mm) D-A9V D-A9 D-M9 D-M9W D-M9V D-M9WV A B A B Bore size (mm) W Hs A B W A B Hs 32 40 50 63 12 [17] 9 1 12 [17] 9 29 8 [13] 5 3 (0.5) 8 [13] 5 27 16 11.5 1.5 16 11.5 32.5 12 7.5 5.5 (3) 12 7.5 30.5 14 <19> 14.5 4.5 14 <19> 14.5 42 10 <15> 10.5 8.5 (6) 10 <15> 10.5 36.5 16.5 17.5 7.5 16.5 17.5 42 12.5 13.5 11.5 (9) 12.5 13.5 40 [ ]: Values for 5 mm stroke with 32 < >: Values for

B Released SET Work 1 Work 2 Work n Atmosphere Max. A: Maximum pressure value when work piece is adsorbed. A B 4 ON = A A B 4 SET OFF = B + Min. B: Minimum pressure value when work piece is not adsorbed. OUT1 auto preset For adsorption verification: In this mode, repeat the adsorption and release of the work piece for a few times. The optimum values will be set automatically.