IDX-OM-W029-B / Series IDU22E-23(-C,L,R,T,V) IDU22E-30(-C,L,M,R,T) IDU37E-23(-C,L,R,T,V) IDU37E-30(-C,L,M,R,T) IDU55E-23(-C,L,R,T,V) IDU55E-30(-C,L,M,R,T) IDU75E-23(-C,L,R,T,V) IDU75E-30(-C,L,M,R,T) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC () * 1 ) JIS B8370 * 2 ) ISO4414 *1) ISO4414Pneumatic fluid power General
b "t| | I-+-fEr_--] | | tsT kp " ] t l t l I I Cable connector type I S I Straiqht tvpe 3 m I I L I Riqht anqle tvpe 3 m I I j N lWithout cable connector I l L-Bracket Model 7 . l00O tvoe v : 2000 tvoe Pressure [rPa 2 kqf/cm, 3 bar 4 PSI kPa Power supply voltage 0 to 10 VDC Thread type 1/8 (1000 tuoe) 2 1/4 (1000. 2000 tvoe) 3/8 (2000 type) Without bracket I Flat bracket L-bracket World
v2 Cushioning Absorbable Bore stroke [mm] kinetic [mm] energy [J] 32 19 2.2 40 19 3.4 50 24 5.9 63 24 11 80 30 20 100 30 29 500 63 300 E: Kinetic energy [J = Nm] m:Load weight [kg] v: Piston speed [m/s] 50 200 40 100 80 32 50 30 Load [kg] 20 At the stroke end, when stopping a large amount of kinetic energy generated by a large load and high speed operation, compression of air is used to
Note 2) Since surge voltage is prevented with a rectifier in the case of AC, it is not an "S" type. 1 Ejector Valve Unit Series ZYY/ZYX How to Order Ejector Valves for ZYX3000 Lead wire/Voltage suppressor specification Plug-in type Serial Transmission Type LOZ LOZ 10 X3 ZY 5 M Z S 15 M Wiring specifications (Vacuum switch) Series Lead wire length 0.6m Lead wire length 3m Lead wire length
Fluid Table (1) Rated Voltage-Electrical Entry-Electrical Option Standard specifications Option (1) Made to Order (2) Water (standard) Turbine oil High temperature water (D, E) Air X500B Vacuum (up to 1.3 x 10 2 Pa) X500B For pure water X500 G C Class B D, T Class H G, C T S Note) S L, Z L, Z S Note) Surge voltage suppressor is attached in the middle of lead wire.
P101. 2 CG5 N A (mm) E max (J) E max (J) 2 E=(m/2)v 20 0.28 0.42 25 0.41 0.65 E J m: (Kg) v m/s 32 0.66 0.91 40 1.2 1.8 50 2.0 3.4 EE max (J) 63 3.4 4.9 80 5.9 11.8 100 9.9 16.7 (2) 2-7. 14 28. 3 13 2 3CDG5 (M4 1~1.2Nm 3 3.
150'25 consult laclory when the desrd stroke s grealer lhan lhe slandard strcke l MPa='l0.20kg cm'z Specif rcations Operation Double acting 1.sN4Pa(1 5.3kgf/cm'; 217PSl) Prool pressure 1.oMPa(1 0.2kgtcm'; 145PSl) o.rzuP"f l zr,(st/"|.t"J tPSr) Max. operating pressure : 012, d,16 Min. operating pressure s20-0100 0.1 lvlPa(1 .okgflcm'i l4PSl) -10-+60'C (14-140'F) Amuent and Iluid 50-500mm/s
Series: 25A-PF3W7, Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature:
Series: 25A-PF3W7, Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: Â
Series: 25A-PF3W7, Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature:
Series: 25A-PF3W7, Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: Â
Series: 25A-PF3W7, Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Series: 25A-PF3W7, Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L;
cord outlet Air outlet Air inlet 22 C Draft air inlet F L 16 M Model IDUS3E IDUS4E Port size J A B C D E F G H K L M 260 470 540 85 130 297 330 315 380 325 440 350 Rc 1/2 85 130 Rc 1/2 260 560 540 440 325 530 297 330 315 470 IDUS6E 315 130 605 540 Rc 3/4 515 485 325 355 325 575 285 110 Note: The diagram above is drawn base on IDUS3E dimension with scale 1:6 3 Stainless Steel Heat Exchanger
Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110
63 50 11 Y59A S S A93 MGT Table unit switch quantity Cylinder with turntable Table unit auto switch type S 1 pc.
Size/Valve Type: 6 (25A, N.C.), Body/Port/Orifice: K (C37; Port 1;, Orifice 25), Voltage/Electrical Entry: J (110VAC, DIN Terminal w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: B (NPT Thread)
Size/Valve Type: 6 (Size: 25A; Valve Type: N.C.), Body/Port/Orifice: P (Body Material: Stainless Steel; Port Size: 1, Orifice Dia.: 25), Voltage/Electrical Entry: J (110VAC; DIN Terminal w/Surge Voltage Suppressor)
Size/Valve Type: 6 (25A, N.C.), Body/Port/Orifice: L (Stainless Steel; Port 1;, Orifice 25), Voltage/Electrical Entry: J (110VAC, DIN Terminal w/Surge Voltage Suppressor)
Size/Valve Type: 6 (25A, N.C.), Body/Port/Orifice: K (C37; Port 1;, Orifice 25), Voltage/Electrical Entry: J (110VAC, DIN Terminal w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: A (G Thread)