7 12 8 47 Up to 300 301 to 800 20 to 300 301 to 800 Without rod boot With rod boot Bore size (mm) P J K KA MM NA PG PH PL S TA TB TC XA XB l ZZ H e f h ZZ 20 25 32 40 M4 x 0.7 depth 7 5 6 M8 x 1.25 24 1/8 21.5 2 65 141 (149) 11 11 M5 x 0.8 3 12 35 178 (186) 30 16 55 198 (206) 0.25 x Stroke M5 x 0.8 depth 7.5 5.5 8 M10 x 1.25 29 1/8 26.5 2.5 73 151 (159) 11 11 M6 x 0.75 3 12 40 193 (201)
Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.
Set the mounting band perpendicularly to cylinder tube. 20 50 63 80 100 25 32 40 D-B7/B80 8 10 9 10 10 11 D-B73C/B80C D-C7/C80 8 10 9 10 10 11 D-C73C/C80C 8 10 9 10 10 11 D-B5/B64 11 11 MX Mounting correctly Mounting incorrectly 13 13 14 14 14 17 D-B59W 18 16 D-G79/K79 8 10 9 10 10 11 Auto Switch Mounting Bracket Part No.
OUTPUT 35 9-3-5. 36 10 3744 11 11-1. 11-1-1. 45 11-1-2. 4548 11-1-3. 48 11-2. 11-2-1. 4952 11-2-2. 53 11-3. 11-3-1. 53 12 12-1. 54 12-2. 54 13 13-1. 5557 13-2. () 5758 14 14-1. 5960 - 1 1 1 1 (ISO/IEC)(JIS) 1) 2) *1) ISO 4414:Pneumatic fluid powerGeneral rules relating to systems ISO 10218-1:2006Robots for industrial environments-Safety requirements-part1
107.5 10 to 50 80 117.5 53.5 11 11 99 116 134 43 10 43.5 77 53.5 117.5 75, 100 53 126 10 to 50 Rod end nut L1 100 136 63 11 11 117 136 154 50 12 43.5 94 63 136 75, 100 Double clevis type: CLQD/CDLQD Double clevis type (mm) CT 4-N Cap bolt Stroke range Without auto switch With auto switch Bore size (mm) CD CT A A B CL B CL 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 36 112 126 CD hole
Internal circuits D-Y7NW(V) Weights DC(+) Brown [Red] (g) Main circuit of switch OUT Black [White] Lead wire length Auto switch part no. 3m 0.5m 54 11 D-Y7NW, D-Y7NWV, D-Y7PW, D-Y7PWV DC() Blue [Black] 54 11 D-Y7BW, D-Y7BWV Dimensions D-Y7PW(V) D-Y7NW, D-Y7PW D-Y7BW M2.5 x 4 Slotted set screw DC(+) Brown [Red] 2.5 Indicator light Main circuit of switch 3.4 OUT Black [White] SMC SMC 6.2 5
W X Y ZZ J 32 34 27 1/8 154 6.5 7 30 198 3.2 32 57 50 6 M10 x 1.25 37 47 13 6.5 22 9 232 M6 x 1.0 40 39.5 27 1/4 161 8 9 33 209 3.2 38 64.5 55 6 M14 x 1.5 41.5 51 16.5 9 24 11 247 M6 x 1.0 50 47 31.5 1/4 183 9 9 40 237 3.2 46 77.5 70 7 M18 x 1.5 47.5 58 20 10.5 27 11 279 M8 x 1.25 63 55.5 31.5 3/8 197 8.5 12 48 251 3.6 56 93 80 7 M18 x 1.5 55 58 23 12 27 14 296 M8 x 1.25 80 61.5 38 3/8 245
Double wiring specification Symbol D Mounting position 11 12 10 11 10 stations 11 stations D Side 11 stations 12 stations Specified layout Note 2) Specified layout (up to 22 solenoids possible) ... ... ... ...
Main circuit of switch OUT Black Mass (g) DC () Blue D-Y7NW(V) D-Y7PW(V) D-Y7BW(V) Auto switch model 11 11 11 0.5 D-Y7PW, Y7PWV Lead wire length (m) 54 54 54 3 DC (+) Brown 88 88 88 5 Main circuit of switch Main circuit of switch Dimensions (mm) OUT Black D-Y7W M2.5 x 4 L Slotted set screw Indicator light DC () Blue 3.4 2.5 SMC SMC 6.2 5 D-Y7BW, Y7BWV 29 OUT (+) Brown Most sensitive position
11.5 12 17 9 9 9 9 13 13 11.5 12 17 17.5 18 23 15 7 9.5 10 15 15 7 19 11 18 18.5 23.5 15.5 9.5 12 12.5 17.5 17 11 21 15 22.5 23 28 20 9.5 12 12.5 17.5 21.5 11 25.5 15 30.5 31 36 28 3 5.5 6 11 29.5 4.5 33.5 8.5 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
107.5 10 to 50 80 117.5 53.5 11 11 99 116 134 43 10 43.5 77 53.5 117.5 75, 100 53 126 10 to 50 Rod end nut L1 100 136 63 11 11 117 136 154 50 12 43.5 94 63 136 75, 100 Double clevis type: CLQD/CDLQD Double clevis type (mm) CT 4-N Cap bolt Stroke range Without auto switch With auto switch Bore size (mm) CD CT A A B CL B CL 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 36 112 126 CD hole
20 11 22 14 60 60 129 MB-SIO . 100 11 4 \20 90 15 158 132 \84 26 13.5 24 17 75 100 '29 25 +008001 (mm) [~ "r.
Station 9 SQ SOL.B SOL.A 23 10 Station 10 SOL.A VFS SOL.B 24 11 Station 11 SOL.B SOL.A 25 12 Station 12 VFR VV5Q21 COM. () Orange Red (+) 13 VQ7 Positive COM spec. Negative COM spec. The total number of stations is tabulated starting from station one on the D-side. Note) When using the negative common specifications, use valves for negative common. (Refer to page 419.)
IP8S-OM09-B SMART POSITIONER (LEVER TYPE) PRODUCT NAME IP8001 Series MODEL/ Series Table of Contents Table of Contents Safety Instructions 3 Introduction 5 Specifications 5 Parameter Settings List 7 Workflow of IP8001 Positioner Setup 8 Operating Principle 9 Mounting 10 Example of Mounting on Actuator 10 Connection of Feedback Lever 11 Feedback Lever Unit 11 Body Cover Unit 11 Piping 12 Selecting
20 to 300 30 27 19 52 112 1/8 26 16 25 2 104 10 (13) 26 7 8 47 to 300 301 to 800 58.5 12 301 to 800 (mm) Bore size (mm) 20 25 32 40 P J K KA MM NA PG PH PL S TA TB TC WA WB WH WW W XA XB 141 (149) 88 5.5 M5 x 0.8 M4 x 0.7 depth 7 5 6 M8 x 1.25 24 M5 x 0.8 21.5 2 65 11 11 15 (16) 23 30 3 12 151 (159) M6 x 0.75 98 6 5.5 8 M10 x 1.25 29 M5 x 0.8 26.5 2.5 73 11 11 15 (16) 25 30 3 12 M5 x 0.8
Refer to How to Order Sub-plate Assembly on page 3-5-11. !3 !4 !
116.5 53.5 11 11 4 x FD FX FZ L G B + Stroke CLS A + Stroke 100 135 63 11 11 CLQ Bore size (mm) FV FX FZ G L L1 M 63 80 100 RLQ 80 99 117 92 116 136 108 134 154 38 43 50 18 20 22 43.5 53.5 53.5 60 77 94 L1 Rod end nut MLU Head Side flange style: CLQG/CDLQG Head Side Flange Style MLGP (mm) Stroke range Without auto switch With auto switch Bore size (mm) FD FT ML1C A A B B 36 46 43.5 53.5
Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Buffer mounting (Male thread) Buffer mounting (Male thread) Mounting Male thread Female thread Female thread Vacuum entry port Female thread Common Female thread Female thread Female thread P. 13-11-91 to 92 P. 13-11-86 to 88 P. 13-11-86 to 88 P. 13-11-89 to
Fig. (2) Note) When there are 10 or fewer manifold block assemblies, and more are added to make a total of 11 or more, a supply/exhaust block assembly must also be added. Hook this part onto the DIN rail, and press down in the direction of the arrow.
Refer to front matters 42 and 43 for Safety Instructions and pages 3 to 11 for Actuator and Auto Switch Precautions. Handling on Shock Absorber Service Life and Replacement Period of Shock Absorber Caution Caution 1.