11 12 2 wire 3 wire 56 Solid state switch D-F7 4 wire 56 14 Write "L" at the end of the part number for 3 meters of lead wire.
0 P1(11) port u R(4) Exhaust port r !5 o !7 A(2) port P2(12) port !4 !3 w !2 !
Comparison between existing and new (AN200 to 400, AN103 to 403, AN103-KM6 to 300-KM12) Male Thread (Resin body) Type New model Existing model New New New Standard Compact type Sonic conductance C [dm3/(sbar)] Length (mm) Noise reduction Model Port size Noise reduction Noise reduction Length (mm) Sonic conductance C [dm3/(sbar)] Sonic conductance C [dm3/(sbar)] Length (mm) Model Model 63
, 11, 12 and 13, which can be ordered using the kit number for each cylinder bore size. 2 Series MHS2 2 Finger Air Gripper Gripping Point The work piece gripping point distance should be within the gripping force ranges given for each pressure in the effective gripping force graphs below.
20 9 11 13 15 17 19 21 23 25 27 20 16 1.0 25 15 18 21 24 27 30 33 37 40 43 32 27 32 36 41 45 50 54 59 63 67 12 0.4 40 42 48 54 60 66 73 79 85 91 97 0 10 20 30 40 50 50 91 101 111 121 131 141 151 161 171 Cylinder stroke [mm] 63 130 140 150 159 169 179 189 199 209 80 240 255 270 285 300 315 329 344 359 With Magnet for Auto Switch 100 426 446 467 488 509 530 551 572 592 100.0 Mass of Cylinder
441 426 468.5 453.5 496 481 523.5 508.5 551 536 578.5 563.5 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations Station n L1 L2 1571 VPA300/500/700 Series VPA500 Series/Dimensions Type 41/Common exhaust: VV3PA5-411-03 Stations 92.5 2 x 7.2 (For mounting) 30 N.C.
Please note that if the forced mode is canceled while PROFINET communication with the PLC is established, the input / output data with the PLC will be shown immediately. -90No.EX-OMY0027 (11) To change the Password, log in using Administrator mode and select CHANGE PASSWORD.
Green L/A IN or L/A OUT Refer to Fault 11. LED is not flashing. At least one SF and/or BF LED is ON red or flashing red. Refer to Fault 12. The valve does not Refer to Fault 13. work correctly. The digital input or output device does not work Refer to Fault 14. correctly. The analogue input or output device does not work correctly. Refer to Fault 15.
400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics Conditions: Upstream pressure 0.7MPa Downstream pressure 0.2MPa Flow rate Q = 20l/min (ANR) 0.30 Downstream pressure MPa 0.25 Starting point 0.20 0.15 0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Upstream pressure MPa Construction ARJ310-01 ARJF310F
100 300 500 300 500 700 1000 2000 2500 3000 4000 4000-06 5000 6000 1000 2000 3000 4000 4000-06 2550 3050 4050 4050-06 3050 4050 4050-06 2060 2560 3060 4060 4060-06 5060 6060 425 625 825 925 3000 210 1020 300 400 500 600 AWM Mist separator regulator VQZ AWD Micro mist separator regulator SQ AS Speed controller VQD SY Flow control valves SYJ SX 3-port solenoid valve (2) VQ VQ VQZ AS Speed
Wiring 1) Passing through the cable (7), cable gland (4), plain washer (5), rubber seal (6) in this order, and then insert into the housing (2). 2) From the terminal block (3), loosen the screw (11), then pass the lead wire (10) through, then again tighten the screw (11). Note 1) Tighten within the tightening torque of 0.5 Nm 15%.
6 Series VH Dimensions: Body Mounted VH600-06/10 2 (A) 4 (B) 32 1 (P) 132 152 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4-11 132 300 223 M15 x 1.5 15 151 150 48 25 4-Rc 3/4, 1 3 (R) 40 5-8-12 7 Hand Valve Series VH Dimensions: Panel Mounted VH21-02 VH31-
(PAT.PEND) Over length L(mm) Gripping moment Mass (g) Bore size (mm) Model (Nm) L MHW2-20D 300 68 20 0.30 MHW2-25D 510 25 0.73 78 905 MHW2-32D 32 93.5 1.61 2135 MHW2-40D 117.5 40 3.70 5100 Auto switch mounting at 4 locations MHW2-50D 154 50 8.27 At the pressure of 0.5 MPa Two finger styles available.
Without light 11 Series VCL Direct Operated 2 Port for Oil 2 Port Solenoid Valve for Fluid Control/Precautions 4 Be sure to read before handling Operating Environment Warning 1. Do not use valves in atmospheres of corrosive gases, chemicals, salt water, water or steam, or where there is direct contact with same. 2. Do not use in an explosive atmosphere. 3.
When connecting piping to a valve, be sure to tighten while holding the valve with a wrench or other tool. 11 Series VCS Direct Operated 2 Port for Steam 2 Port Solenoid Valve for Fluid Control/Precautions 3 Be sure to read before handling Operating Environment Wiring Warning Caution 1. As a rule, use electrical wire of 0.5 to 1.25mm for wiring.
For Water Digital Flow Switch Series PF2W How to Order Integrated Display Type PF2W7 20 03 27 M Flow rate range Thread type 04 20 40 11 0.5 to 4 L/min 2 to 16 L/min 5 to 40 L/min 10 to 100 L/min Unit specifications Nil N F Rc NPT G With unit switching function Note1) Fixed SI unit Note2) Nil M Lead wire (Refer to page 322.)
Series VH Dimensions: Body Mounted VH600-06/10 2 (A) 4 (B) 32 1 (P) 132 152 4-11 132 300 223 M15 x 1.5 15 151 150 48 25 4-Rc 3/4, 1 3 (R) 40 5-8-12 Hand Valve Series VH Dimensions: Panel Mounted VH21-02 VH31-02/03 ( ): Long handle type 4 (B) 2 (A) 25 25 (32) 25 4 (B) SA 1 (P) 3 (R) 1 (P) 74 62 62 49 VA 2 (A) SA 49 4-5.5 4-6.6 VA 62 VM 134(159) VR 97(122) VH 125 94 VHS M40 x 1.5 8
Furthermore, connect soft start-up valves to the outlet side of the F.R.L. combination. 11 AV2000-A/3000-A/4000-A/5000-A Series Specific Product Precautions 3 Be sure to read this before handling the products. Refer to the back cover for safety instructions.
Furthermore, connect soft start-up valves to the outlet side of the F.R.L. combination. 11 AV2000-A/3000-A/4000-A/5000-A Series Specific Product Precautions 3 Be sure to read this before handling the products. Refer to the back cover for safety instructions.
Lights up during remote operation. 11 Changing pressure unit Pressure unit can be changed. MPa PSI HECR t [RUN] lamp Lights up when the product is started, and goes off when it is stopped.