HECR Circulating fluid return port Rc3/4 HEC Barrel nipple 20A 144 HEB Y-strainer (40 mesh) 20A HED Flow direction HEA Y-strainer (20A) (Accessory) IDH Barrel nipple (20A) (Accessory) 107 HRS100/150 Series Standard Type Recommended External Piping Flow External piping circuit is recommended as shown below. 7 Thermo-chiller 2 Facility water outlet (Water-cooled refrigeration) Facility water

/Japanese 1 pc.), Y-strainer 20A 1 pc., Barrel nipple 20A 1 pc., Drain pan for the pump 1 pc.

OUT 1 Thread type Rc NPT NPTF G Nil N T F IN Voltage 1 2 3 4 5 6 36 100VAC 200VAC 110VAC 220VAC 24VDC 12VDC 230VAC Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Symbol 01 02 03 04 06 Class B with AC has a built-in rectifying circuit. Class H is AC only. Without rectifying circuit. Contact SMC regarding other voltages.

Thread type OUT (2) Rc NPT G Nil N F 1 (1) IN Port size Voltage Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Consult SMC regarding other voltages.

(value under the prescribed conditions) 2 1/4 ( 8A) 1/4 ( 8A) VCW (for water) 2 port solenoid valve NBR (FKM) (EPDM) (PTFE) 3 3/8 (10A) Brass (Stainless steel) 1/2 (15A) 1/4 ( 8A) 3/8 (10A) 4 1/2 (15A) 3/4 (20A) Note 1) 10 is N.C. (normally closed) only. OUT OUT IN IN N.C. N.O. 100 Electrical Terminology 1.

VQ Electrical entry G C D T Body size 5 6 7 8 9 Grommet Conduit DIN terminal Conduit terminal 20A 25A 32A 40A 50A VX2 VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Refer to the table (2) given below for availability.

Without sub-plate VH VPA454/474 00 03 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 (32A) 1 4 1 (40A) 1 2 1 VHS standard 5 Body size 04 06 10 12 14 VPA450 Piping 3 4 standard 7 11 4 JIS Symbol 2 position double VPA4250/4270 0 Side ported 1 Bottom ported 2 position single VPA4150/4170 VPA470 4 W/o sub-plate Option Specifications Fluid Air 3 position exhaust center VPA4450 3 position closed center

Orifice and Port Size Combinations Orifice size (mm) Class Port size Note) T Conduit terminal TL Conduit terminal with indicator light 2 3 4 5 7 10 D DIN terminal DL DIN terminal with indicator light DO DIN terminal (without connector) 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) 1/4 (8A) 3/8 (10A) 4 1/2 (15A) 3/4 (20A) Connector Note) 10 is available only for N.C.

90 Series 6-4 IDX-OM-W095 7 7.1 IDFC60-23 IDFC70-23 IDFC80-23 IDFC90-23 2080 0.151.0MPa (7) (1) () 2045 oC85% (2) 20 oC 4.7m 3/min 7.8m 3/min 10.9m 3/min 15.4m 3/min 10 oC 2.8m 3/min 4.7m 3/min 6.5m 3/min 9.2m 3/min 3 oC 0.9m 3/min 1.6m 3/min 2.2m 3/min 3.1m 3/min 0.7MPa 50 oC 35 oC () 230V (50Hz) 10% (3) (4) 1.0kW 1.6kW 2.4kW 2.8kW (4) 5.5A 8.0A 13.0A 14.0A 30mA (5) 10A 15A 20A

. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) The 20A, 20B, and 20C series have been added to the product lineup.

VNA1A -6A, 8A, 10A VNA2 -10A, 15A VNA3 -20A VNA4 -25A VNA5 -32A VNA6 -40A VNA7 -50A No.

Applicable piping size Applicable tubing size (inch) 2 4 4 5 5 5 6 6 6 2 2 3 1 2 3 2 3 4 B B C A B C B C D 6 x 4 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 1/4" x 5/32" 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 12 x 10 1/2" x 3/8" 19 x 16 3/4" x 5/8" 25 x 22 1" x 7/8" Dimensions Union Flange: LQ3F Metric Size (S) T P M L2 L2 L1 L1

Electrical option VDW Nil S L Z None With surge voltage suppressor With indicator light With light/surge voltage suppressor Body size 4 5 6 7 8 9 VQ 15A 20A 25A 32A 40A 50A VX2 Refer to the table (2) given below for availability.

Body type Body type Plug-in type Non plug-in type VVFS2000-20A-1 VVFS2000-20A-2 Part no. 1 8 Plug-in type Non plug-in type VVFS2000-P-01-1 VVFS2000-P-01-2 VVFS2000-P-02-1 VVFS2000-P-02-2 Rc Body type Plug-in type Non plug-in type VVFS2000-10A Part no. Part no.

SX3000 SY3000-26-9A SX5000 SY5000-26-20A SX7000 SY7000-26-22A Bolt and gasket part no. Series Assembly part no. Port size M5 x 0.8 SX3000 SX3000-39-1 A SX5000 SX5000-39-1 A SX7000 SX7000-39-20A Series Assembly part no.

Installation Example Flange body I type (Flange mounting type) Flange body type Direct piping type Flange type Solenoid valve type Air operated type Variations Piping Controller dedicated for operation Series VXFC Flange body II type Port size Type Flange body I type Electrical entry Direct piping type Flange type Flange mounting type Through hole mounting type Solenoid valve type only 20A

(value under the prescribed conditions) 2 1/4 ( 8A) 1/4 ( 8A) VCW (for water) 2 port solenoid valve NBR (FKM) (EPDM) (PTFE) 3 3/8 (10A) Brass (Stainless steel) 1/2 (15A) 1/4 ( 8A) 3/8 (10A) 4 1/2 (15A) 3/4 (20A) Note 1) 10 is N.C. (normally closed) only. OUT OUT IN IN N.C. N.O. 100 Electrical Terminology 1.

(Common EXH type) 32 16 3 R 1(P) 40.3 4(A) 2(B) 03: Rc 3/8 04: Rc 1/2 3(R') 5(R1) 3(R2) Circuit diagram Plug-in type Plug lead type 2-6-34 Base Mounted Series VQ5000 Throttle valve spacer 179 (Plug-in type) 133 (Plug lead type) 32 16 VVQ5000-20A-1 (Plug-in type) VVQ5000-20A-5 (Plug lead type) 3 5 1(P) 4(A) 40.3 A throttle valve spacer is mounted on a manifold block to control cylinder speed

Grommet Conduit DIN terminal Conduit terminal 10A 15A 20A 25A Body size Solenoid Coil Coil: Class B, Class H 3 4 3 8 1 2 Port size (Thread) 1 2 1 4 3 8 , , , 1 Rated Voltage 100 VAC, 200 VAC, 110 VAC, 220 VAC, 240 VAC, 230 VAC, 48 VAC, 24 VDC, 12 VDC VXD227 2 0 VXD238 2 0 VXD239 2 0 Model 32A 40A 50A Body size Material Body Brass (C37)/CAC407, Stainless steel Seal NBR, FKM, EPDM Port

Electrical option Nil S L Z VDW None With surge voltage suppressor With indicator light With light/surge voltage suppressor VQ Body size 3 4 5 6 7 8 9 10A 15A 20A 25A 32A 40A 50A VX2 Refer to the table (2) given below for availability.