Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: None, Calibration Certification: K (w/Certificate)
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: None, Calibration Certificate: K (w/Certificate)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: K (w/Fluid Fill Port)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: K (w/Fluid Fill Port)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: (None), Exhaust Check Valve: K (AKH06-00, for 6mm tubing)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: (None), Exhaust Check Valve: K (AKH06-00, for 6mm tubing)
Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: C6 (6mm), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: None, Operation Manual/Calibration Certificate: K (with Operation Manual and Calibration Certificate
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: M5 (M5 Female Thread), Option 1: w/o Lead Wire, Option 2: None, Option 3: K (Operation Manual, Calibration Certificate)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: K (Operation Manual, Calibration Certificate)
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: N02 (NPT 1/4), Option: None, Attachment: C (Clear Cover w/o Protrusion, is not Removable)
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: N02 (NPT 1/4), Option: M (w/M5, Female Thread), Attachment: C (Clear Cover w/o Protrusion, is not Removable)
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: N01 (NPT 1/8), Option: None, Attachment: C (Clear Cover w/o Protrusion, is not Removable)
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: 02 (R 1/4), Option: M (w/M5, Female Thread), Attachment: C (Clear Cover w/o Protrusion, is not Removable)
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: N01 (NPT 1/8), Option: M (w/M5, Female Thread), Attachment: C (Clear Cover w/o Protrusion, is not Removable)
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: 01 (R 1/8), Option: None, Attachment: C (Clear Cover w/o Protrusion, is not Removable)
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: 01 (R 1/8), Option: M (w/M5, Female Thread), Attachment: C (Clear Cover w/o Protrusion, is not Removable)