SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-06-DO-00T"

Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it. If the cylinder is put into operation without applying grease to the seal, it could cause the seal to wear significantly, leading to premature air leakage. 3.

Do not replace the non-rotating guide. Since the non-rotating guide is press fitted, the entire cover assembly needs be replaced instead of a single part. 200

Do not replace the non-rotating guide. Since the non-rotating guide is press fitted, the entire cover assembly needs be replaced instead of a single part. 202

Do not disassemble the trunnion style. Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 35

CA2H100A-PS Do not disassemble the trunnion style. Seal kit includes !4, !5 and !6. Order the seal kit based on each bore size. Seal kit includes a grease pack (40, 50: 10 g, 63: 20 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 40

Piston seal NBR Cushion valve seal NBR O-ring MBW100-PS Cylinder tube gasket NBR Do not disassemble the trunnion style. Seal kit includes !2, !3, !4 and !6. Order the seal kit based on each bore size. Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed.

CA2WH100A-PS Do not disassemble the trunnion style. Seal kit includes !0, !1 and !2. Order the seal kit based on each bore size. Seal kit includes a grease pack (40, 50: 10 g, 63 or more: 20 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 41

Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it. If the cylinder is put into operation without applying grease to the seal, it could cause the seal to wear significantly, leading to premature air leakage. 3.

Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it. If the cylinder is put into operation without applying grease to the seal, it could cause the seal to wear significantly, leading to premature air leakage. 3.

Do not use a stop valve to prevent damage to the differential pressure gauge if the valve is inadvertently left open or closed. 2) Install the differential pressure gauge vertically. 3) The piping of the differential pressure gauge must be connected securely because it will break if it becomes detached.

Additionally, do not put the tube end in the liquid. This may cause the back pressure to be applied, resulting in poor performance. 3.Liquids cannot be collected by the air. 1076 A

. * If the step motor and servo motors do not meet your specifications, also consider the AC servo specification (Page 46). 38 Model Selection LEF Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Clean Room Specication For the LECPA, refer to page 40.

When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area. Use special tool when crimping. (For the crimping tool, please consult with SMC.)

.: B21-1P 0.12 How to Order AP100 01 Cylinder cushion Application Example Special specifications Pressure control valve Thread type Symbol Nil Specifications Symbol Nil N F Type Rc NPT G Set pressure range 0.02 to 0.2 MPa X201 AP100 Accessory Connection thread Symbol Nil B Description With bracket Symbol 01 02 Size 1/8 1/4 Precautions Relief Characteristics Do not use this product as a

Do not use a tool when rotating the handle. When the handle is rotated with a tool, it may apply excessive torque to the handle or inside the valve body and it may cause damage. Rotate the handle by hand. 9. When locking the valve with LOTO feature in the closed position, use safety lockout hasp.

Do not use a tool when rotating the handle. When the handle is rotated with a tool, it may apply excessive torque to the handle or inside the valve body and it may cause damage. Rotate the handle by hand. 9. When locking the valve with LOTO feature in the closed position, use safety lockout hasp.

(To set the pressure, do so in the direction of pressure increase.) 2. Set the outlet pressure to 85% or less of the inlet pressure. Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 387 to 391 for Precautions on every series. Inlet pressure (MPa) Mounting/Adjustment Warning 1.

Do NOT pipe upwards. AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12

Screw the locking ring into the switch (do not tighten with pliers, hand tishten only). Lead Wire with Connector Length 0.5 m 3 m 5 m Part no.

Note) Do not apply rotational torque to the piston rod. When the stroke reading cylinder is used near a motor, welding machine or other source of noise generation, there is a possibility of miscounting. In this case, noise should be suppressed as much as possible and the following countermeasure should be taken. 1. Connect the shield wire to FG (flame ground). 2.