Applicable tube sizes are 3.2 to 16 and 1/8" to 1/2".
5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g
5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g
5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g
ModelFlow-rate characteristicsOperating pessure rangeNote)Weight(g) C [dm3/(s?bar)]bCvq Used with vacuum (Pa?abs)w Used with pressure (MPa?G)11/8, 1/42VX2140.630.630.230.1 to atmospheric pressure0 to 1.0300
Manifold Base for VX21/22/23 series solenoid valves for air, Base material: aluminum , 1/8 or 1/4 individual port size, 2 - 10 stations available as standard, Options: Rc, G or NPT threads, oil-free, MFLD BASE, VX2200 SERIES, VALVE, VVX* MANIFOLD VX SERIES, PJ, VVX* BASE MT 1/4, .70878 lb, SizePort sizeOrifice diameter (mm?)
Manifold Base for VX21/22/23 series solenoid valves for air, Base material: aluminum , 1/8 or 1/4 individual port size, 2 - 10 stations available as standard, Options: Rc, G or NPT threads, oil-free, MFLD BASE, VX2300 SERIES, VALVE, VVX* MANIFOLD VX SERIES, PJ, VVX* BASE MT 1/4, 1.22320 lb, SizePort sizeOrifice diameter (mm?)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: N (None)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: N (None)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle)
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: R4 (w/Control Unit, Supply Port: Right Side, With regulator, Square type pressure gauge, 0.2 MPa), 2 Port Solenoid Valve Rated Voltage: 2 (110 VAC)
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: N (None)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 1
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge, 0.4 MPa)
Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 06 (ø6)
Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 10 (ø10)
Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 06 (ø6)
Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 08 (ø8)
Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 08 (ø8), Seal Method: w/o Sealant, Option: B (None)