Magnet: D (Built-in), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 5000 (50"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC22 (Viton Seals)
Magnet: D (Built-in), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 0800 (8"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC35 (with Coil Scraper)
Series: NCDA1 (Standard w/ Magnet), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 0150 (1 1/2"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: SF (Short Female, Threaded)
Series: NCDA1 (Standard w/ Magnet), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 5000 (50"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)
Series: NCDA1 (Standard w/ Magnet), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 1200 (12"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 0400 (4"), Air Cushion: Both Ends (Air Cushion), Adjustment Range: B (0 to 2"), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC9 (Adjustable Stroke, Retraction Type)
Magnet: D (Built-in), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 0800 (8"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC22 (Viton Seals)
For Air 1.6 1.4 Upstream pressure of valve P1 Downstream pressure P2 [MPa] 1.5 MPa 1.6 MPa 1.2 1.3 MPa 1.4 MPa Subsonic 1.0 Critical pressure 1.2 MPa 1.1 MPa 0.8 1.0 MPa 0.9 MPa 0.8 MPa Sonic 0.6 0.7 MPa 0.6 MPa 0.5 MPa 0.4 0.4 MPa 0.3 MPa 0.2 0.2 MPa 0.1 MPa 0 VXB215A D(H) 10 12000 14000 8000 2000 4000 6000 VXB215B E(H) 16000 14000 10 12000 8000 2000 4000 6000 VXB215C F(H) 10 2000 6000 8000
Low noise 60 ZK2A07 (Silencer exhaust) ZK2G07 (High-noise reduction silencer exhaust) 46 dB (A) 1 50 1 Nozzle size: 0.7 (Under SMCs measurement conditions) 40 Noise level [dB (A)] 30 Reduces high-frequency range from 2000 to 20 Hz. 20 10 0 200 2000 20 Frequency [Hz] Suction flow Improved by up to approx. 20% Max. suction flow [L/min (ANR)] Nozzle size Exhaust type 40 80 Approx. 20% High-noise
Data 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 0.2 Minimum operating pressure (MPa) 40 1500 2000 0.16 0.16 0.14 0.15 0.12 0.15 Note 1) Please contact SMC if the maximum stroke will be exceeded.
However, when exceeding a 2000 mm stroke, specify -XB11 at the end of the model number. Refer to the made to order specifications on page 8-14-24.
Note) Except SI Unit Manifold Solenoid Valves Manifold Solenoid Valves Manifold Solenoid Valves Series SY3000/5000 Series SV1000/2000/3000 Series S0700 Series VQC1000/2000/4000 IP67 IP40 IP67 IP67 Note) The SY3000/5000, S0700, and VQC1000/2000/4000 are not UL-compatible.
03 04 1/8 1/4 3/8 1/2 Type of setting Regulating pressure range 0 Basic type (Handle) For 90-IR1000/2000 series 0 1 2 0.005 to 0.2 MPa 0.01 to 0.4 MPa 0.01 to 0.8 MPa For 90-IR3000 series 0.01 to 0.2 MPa 0.01 to 0.4 MPa 0.01 to 0.8 MPa 0 1 2 *Specifications and dimensions for the 90-series are the same as standard products.
The spacing of the side support must be no more than the values shown in the graphs at right. 200 200 190 190 (2100) (2100) (2100) 180 180 170 170 160 160 m 150 150 140 140 (2400) (2400) (2400) (2400) (2400) 130 130 l (1800) (1800) (1800) 120 120 Weight m (kg) Weight m (kg) 110 110 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) (2000) 90 90 (1500) (1500) (1500) MY1CW63 MY1CW63 m 80 80
2500 3000 28.5 3/8, 16 3/8, 16 3/8, 16 1/2, 16 100 =0.7 38 47 0.5 56.5 0.1 0.3 50 10, 12, 16 1/4, 3/8 500 15 63 1000 1500 2000 2500 3000 30 3/8, 16 1/2, 16 1/2, 16 3/4, 16 3/4, 16 0 45 1,000 2,000 3,000 60 Maximum speed Vmax [mm/s] 75 80 89.5 16 3/8, 1/2 500 24.5 =0.7 1000 1500 2000 2500 3000 500 1000 1500 2000 2500 3000 48.5 3/8, 16 1/2, 16 3/4 3/4 3/4 3/8 1/2, 16 3/4 3/4 3/4 3/4 150 80
Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting
Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting
Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting
Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting
VX2 Table (1) Indication of Flow Rate Characteristics VXK Indication by international standard Corresponding equipment Other indications Conformed standard VXD VXD ISO 6358: 1989 JIS B 8390: 2000 C, b VXZ Pneumatic equipment JIS B 8390: 2000 Equipment: JIS B 8379, 8381-1, 8381-2 VXS S Cv VXB ANSI/(NFPA)T3.21.3 R1-2008 IEC60534-1: 2005 IEC60534-2-3: 1997 JIS B 2005-1: 2012 JIS B 2005-2-3