10% or less)IP650 to 50C1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration in each X, Y, Z direction for 2 hrs, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
normally open styles.3 port, pilot poppet type valve , Available with power saving circuit to reduce power consumption , Port sizes from 1/8 to 1/2, depending on series , Thread types: Rc, G, NPT, NPTF, VALVE, SOL, VALVE, VP3/5/7 SOL VALVE 3-PORT, HA, VP3/5/7 BODY PT 3/8, .61068 lb, ModelPressure specificationsResponse time ms (at 0.5 MPa) Without light/surge voltage suppressorWith
normally open styles.3 port, pilot poppet type valve , Available with power saving circuit to reduce power consumption , Port sizes from 1/8 to 1/2, depending on series , Thread types: Rc, G, NPT, NPTF, VALVE, SOL, JPN SPL, VALVE, VP3/5/7 SOL VALVE 3-PORT, G8, VP3/5/7 BODY PT 3/8, .60261 lb, ModelPressure specificationsResponse time ms (at 0.5 MPa) Without light/surge voltage suppressorWith
normally open styles.3 port, pilot poppet type valve , Available with power saving circuit to reduce power consumption , Port sizes from 1/8 to 1/2, depending on series , Thread types: Rc, G, NPT, NPTF, VALVE, SOL, VALVE, VP3/5/7 SOL VALVE 3-PORT, HA, VP3/5/7 BODY PT 3/8, 1.14640 lb, ModelPressure specificationsResponse time ms (at 0.5 MPa) Without light/surge voltage suppressorWith
(de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns200 g1/8, 1/4
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns200 g1/8, 1/4
(de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
Purpose, 3 Wire PNP, Vertical, Gripper Sw. Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number Switch at Gripper: S (1 pc), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation Sw. Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Body Size: 3 (3/8), Type: 3 (Universal), Control Type: 0 (Meter-out), Indicator Direction: 1(180°), Thread: R, Port Size: 03 (3/8), Applicable Tubing O.D.: 12 (ø12), Seal: S (w/Sealant)
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FSG, Thread: R (or None), Port Size: 03 (3/8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 08 (ø8), Seal: S (with Sealant)
Plug Connector or I/O Cable Length for JXC: 3 (3)
Stations: 10 Stations, Port Size: C8 (ø8 One-touch Fitting), SI Unit: ZENN (EtherNet/IP, -COM), Number of Input Blocks: 3 (Input Block 3 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust)
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 1 (Meter-in), Model: 1FS, Thread: R (or None), Port Size: 03 (3/8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 08 (ø8), Seal: S (with Sealant)
SMC s newest?micro mist separator, series AFD is?available in 3 sizes; 1/4 (20), 3/8 (30) and 1/2 (40).? Rc(PT), PF and NPT threads are available. Port sizes range from 1/8 to 3/4. Body size 30 and 40 now have a transparent bowl guard that offers 360 visibility, while completely protecting the bowl from the environment.? Accessories include a bracket, and float type auto drain.
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 1 (Meter-in), Model: 1FSG, Thread: R (or None), Port Size: 03 (3/8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 08 (ø8), Seal: S (with Sealant)
Stations: 5 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: ZENN (EtherNet/IP, -COM), Number of Input Blocks: 3 (Input Block 3 pcs.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust)