Do not use a tool when rotating the handle. When the handle is rotated with a tool, it may apply excessive torque to the handle or inside the valve body and it may cause damage. Rotate the handle by hand. 9. When locking the valve with LOTO feature in the closed position, use safety lockout hasp.
(To set the pressure, do so in the direction of pressure increase.) 2. Set the outlet pressure to 85% or less of the inlet pressure. Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 387 to 391 for Precautions on every series. Inlet pressure (MPa) Mounting/Adjustment Warning 1.
Do NOT pipe upwards. AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
Screw the locking ring into the switch (do not tighten with pliers, hand tishten only). Lead Wire with Connector Length 0.5 m 3 m 5 m Part no.
Do not use it in such a way that a load could be applied to the piston rod during the retraction. The spring that is built into the cylinder provides only enough force to retract the piston rod. Thus, if a load is applied, the piston rod will not be able to retract to the end of the stroke.
Do not add the suffix (N) indicating no lead wire to the part numbers of models D-A3A, A44A. G39A and K39A. Lead wire length symbols: 0.5 m Nil (Example) C73C 3 m L (Example) C73CL 5 m Z (Example) C73CZ None N (Example) C73CN In addition to the models in the above table, there are some other auto switches that are applicable.
Load Load (a) (b) Thrust bearing Flexible coupling Bearing Size Allowable thrust load (N) Allowable radial load (N) (a) (b) 10 15 20 30 40 7.8 15.7 14.7 9.8 19.6 19.6 29.4 49 49 49 98 78 59 108 98 MSQX Do not allow the load and moment applied to the table to exceed the allowable values shown in the table below.
1. 7 stations (15 stations) Note 1) Be careful that the packing and the O-ring do not fall out of the groove. Note 2) The tightening torque of bolt !1 should be 2 to 2.2 N. (2) (1) 8 stations Note 1) Regardless of the D-sub connector mounting position, stations are to be counted from D side as the 1st one. Note 2)D-sub connector can use up to 8 stations in on side fitting (Type FD U).
1. 7 stations (15 stations) (2) (1) Stations Note 1) Be careful that the packing and the O-ring do not fall out of the groove. Note 2) The tightening torque of bolt !1 should be 2 to 2.2 N. Note 1) Regardless of the D-sub connector mounting position, stations are to be counted from D side as the 1st one. Note 2) D-sub connector can use up to 8 stations in on side fitting (Type FD U ).
DOZ is not available. 2 Other Option Electrical entry 3 position closed center G: Grommet Lead wire length 300 mm L: L plug connector With lead wire LN: L plug connector Without lead wire LO: L plug connector Without connector D: DIN terminal 3 3 position exhaust center 4 M: M plug connector With lead wire MN: M plug connector Without lead wire MO: M plug connector Without connector DO:
Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.
(Do not use any tools.) The initial exhaust rate is adjusted by turning the adjustment nut counterclockwise.
To prevent this, do not set the supply pressure higher than necessary. Soft workpiece Workpiece that has concave/convex surfaces As soft workpieces are easy to deform, there is a tendency for the workpiece to touch the bottom of the non-contact gripper. Please be aware that the workpiece may touch the gripper before using.
Do not tighten the initial air supply flow any further than the minimum supply flow position, as this may result in component damage, or in increased time needed to attain a vacuum in the vacuum chamber due to a decline in the displacement capabilities of the gas accumulation part (bellows chamber). 1.
Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.
When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area. (Crimping tool: model no. DXT170-75-1) Set point ON When assembling the connector to the switch housing, push the connector straight onto the pins until the lever locks into the housing slot.
Do not use a pair of pliers, nippers, or scissors because they could result in an uneven cut or cause the tube to become flattened. As a result, it might not be possible to connect the tubing, or after the tube has been connected, it could pull out or allow air to leak.
Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.
Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it. If the cylinder is put into operation without applying grease to the seal, it could cause the seal to wear significantly, leading to premature air leakage. 3.
Do not replace the bushings. The bushings are press-fit. To replace them, they must be replaced together with the cover assembly. 2. To replace a seal, apply grease to the new seal before installing it. If the cylinder is put into operation without applying grease to the seal, it could cause the seal to wear significantly, leading to premature air leakage. 3.