SMC Corporation of America
Elite Part Number Search
Search Results "NCDGBA63-1000-XC6"

(Example: When the value can be displayed down to 0.001 MPa for the product for 0 to 1 Mpa, the resolution is 1/1000) Display resolving power Displayed pressure value can be adjusted within the range of 5%R.D. (5% of displayed value).

(Example: If a product for 0 to 1 MPa can indicate pressure by 0.001 MPa, the display resolution is 1/1000.) Indication unit The unit of pressure used on the display. Internal voltage drop Refer to "Residual voltage". K Key lock (function) A function that locks the setting buttons so that no accidental setting changes can be made. L Load impedance Refer to "Max. load impedance".

, Guide Maximum load weight [g] Horizontal: 1000, Vertical: 100 Horizontal: 1000, Vertical load not Vertical: 50 allowed.

HRZ001-L HRZ002-L HRZ004-L HRZ001-L1 HRZ002-L1 HRZ004-L1 HRZ001-L2 HRZ002-L2 HRZ004-L2 HRZ008-L2 HRZ001-H HRZ002-H HRZ004-H HRZ008-H HRZ001-H1 HRZ002-H1 HRZ004-H1 HRZ008-H1 HRZ002-W HRZ008-W HRZ002-W1 HRZ008-W1 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX 2min 1min 30s 20s Operating time 10s 5s 2s MIN 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600 700 1000 1500 2000 3000

For VQZ200/300/1000/2000/3000 Push type (Tool required) Push down on the manual override button with a small screwdriver until it stops. Release the screwdriver and the manual override will return.

[Number of emitter cartridges/Bar weight] Bar length (mm) 300 380 620 780 1100 1260 1500 1900 2300 Number of emitter cartridges 3 4 7 9 13 15 18 23 28 Weight (g) 330 400 600 720 1000 1100 1500 2000 2500 29 Doc.No.IZ-OMK0015D 4-2.

Non-rotating accuracy when retracted and when no load is applied should be not more than the values shown in the table. 1000 Bore size [mm] Non-rotating accuracy MGPKM MGPKL 12 0.07 16 0.05 20 0.06 25 32 0.05 0.03 40 50 0.04 100 50 40 32 25 20 10 Load mass [kg] 16 12 1 0.1 0.01 100 1000 500 Max. speed [mm/s] 6 MGPK Series Replacement Parts: MGPKM, MGPKL Common 12 to 32 (101 mm stroke

lead wire and case) Withstand voltage 10 to 60C Ambient temperature IEC60529 Standard IP67 (2) Enclosure 1) Electrical entry: Connector type (A73C/A80C/C73C/C80C): 1000 VAC/min.

(between lead wire and case) 1000 VAC for 1 min.

Auto switch operating range (mm) _ Load operating time V(mm/s) = x 1000 4. Keep wiring as short as possible. As the length of the wiring to a load gets longer, the rush current at switching ON becomes greater, and this may shorten the products life. (The switch will stay ON all the time.) 1) Use a contact protection box when the wire length is 5m or longer. 7.

Screw lead LC1-1(Either T-nuts or T-brackets for mounting) LC1-1-1000 (Controller connector) LC1-1-2000 (Controller connector) (Refer to page 85.) F H L 6mm 10mm 20mm Note) The following options are necessary for operating and setting the controller.

] 0.3 Rotational torque [N.m] MQR12 MQR8 MQR8 20 MQR4 MQR2 MQR12 0.2 10 0.1 MQR1 0 0 0 1000 2000 3000 0 500 1000 1500 2000 2500 3000 Rotation speed [min-1 (r.p.m)] Rotation speed [min-1 (r.p.m)] Note 1: Value when no pressure applied.

B80CL N (Example) B80CN * : Manufactured upon receipt of order Stroke Long stroke (mm) Standard stroke (mm) Model Bearing Bore size (mm) 20 25 32 40 50 75, 100, 125, 150, 200 250, 300, 350, 400 MGCM Slide bearing 350, 400, 450, 500 350, 400, 450, 500, 600 75, 100, 125, 150, 350, 400, 450, 500, 600, 700, 800 200, 250, 300 MGCL Ball bushing baering 350, 400, 450, 500, 600, 700, 800, 900, 1000

V = 2gH/1000 x 60 20 12 = 2 x 9.8 x 15/1000 x 60 = 32.5 (m/min) 20 L=60mm 20 L=50mm . Obtain the intersection of the collision speed V and the total weight of the work piece m. Confirm that the value is within the operating range of the point of application L = 60mm.

Lead wire length 2000 mm Cover Concave Pin Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Lever DC indicator Socket Part no.

Lead wire length 2000 mm -+ Socket Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Lead wire Connector Hook For DC V114-5LO SY100-30-4A-20 For AC V114A-1LO SY100-30-1A-20 2.

For lead wire length (1000 mm) Solenoid valve: VZ2150-5M0-015 pcs. Connector assembly: DXT170-80-4A-105 pcs. Crimping the Lead Wire and Socket Peel 3.2 to 3.7 mm of the tip of lead wire, enter the core wires neatly into a socket and crimp it with a special crimp tool. Be careful so that the cover of lead wire does not enter into the crimping part.

Cylinder Speed Chart Bore size Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm Series MB, CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Enclosure Series Average speed (mm/s) IP65 compatible T kit (Terminal block box) 5 wiring types have been standardized to facilitate easy wiring work and maintenance.

Inch size 3/8" 5/16" 1/4" 5/16" 1/4" 5/32" 1/8" Flow rate (l/min (ANR)) OUT 1000 680 440 480 420 210 150 IN OUT IN High pressure Effective area (mm2) 15.2 10.4 6.7 7.3 6.4 3.2 2.3 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.