This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, HIGH MAG RESIST, ACTUATOR, CA1/CA2 TIE-ROD CYLINDER, MC, 40MM CA1 OTHERS (COMBO), .00000 lb
110 + 55 120 + 55 10 + 55 100 + 55 "n" pcs.
60 65 40 45 50 55 60 65 45 50 55 60 65 70 75 80 85 90 50 55 60 65 70 75 80 85 90 95 30 35 40 45 50 55 30 35 40 45 50 55 35 40 45 50 55 60 65 70 75 80 40 45 50 55 60 65 70 75 80 85 CQ-M3 x 40L x 45L x 50L x 55L x 60L x 65L CQ-M3 x 40L x 45L x 50L x 55L x 60L x 65L CQ-M5 x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 90L CQ-M5 x 50L x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 90L
CQ2 Mounting Bolt for CDQSK MU Mounting bolt Mounting bolt C' D' 35 40 45 50 55 60 35 40 45 50 55 60 40 45 50 55 60 65 70 75 80 85 45 50 55 60 65 70 75 80 85 90 Model C D 30 35 40 45 50 55 30 35 40 45 50 55 35 40 45 50 55 60 65 70 75 80 40 45 50 55 60 65 70 75 80 85 Special long bolt for through hole mounting is available as an option. How to Order: Specify the required bolts.
Fieldbus Protocols: CC-Link, EtherNet/IP; Configuration Software: ACT-Connected, free to download; Operation Modes: Direct Numerical, Step Instruction, Simple Direct Value, IO; LED Display: Power, Alarm, Gateway Status, Communication Status; Mounting Options: Direct or DIN Rail; Ambient Temperature Range: 0 to 55°C; Power Supply: 24 VDC ±10%
Compatible Actuators: LE2* Series ; Actuator Axes: CH A (1 axis) or CH A + CH B (2 axis) ; LED Display: LED (Red/Green) for Motor ON and Alarm ; Ambient Temperature Range: 0 to 55°C ; Power Supply: 24 VDC ±10% (supplied by gateway connection)
Thrust Force(N): 55, Noise Filters: Not Provided, Table Length L1(mm): 102.5, Operating Environment: Standard, Positioning Repeatability(µm): ±50, Maximum Velocity(mm/sec): 200, Size: 16, Motor Type: Step motor (24‑V DC servo), Motor mounting position: In-line motor type / D type, Motor options: No options, Mounting support: Without side holder, Actuator/cable type: Standard cable, Actuator
Thrust Force(N): 55, Noise Filters: Not Provided, Table Length L1(mm): 130.5, Operating Environment: Standard, Positioning Repeatability(µm): ±50, Maximum Velocity(mm/sec): 200, Size: 16, Motor Type: Step motor (24‑V DC servo), Motor mounting position: In-line motor type / D type, Motor options: No options, Mounting support: Without side holder, Actuator/cable type: Standard cable, Actuator
Thrust Force(N): 55, Noise Filters: Not Provided, Table Length L1(mm): 102.3, Operating Environment: Standard, Positioning Repeatability(µm): ±50, Maximum Velocity(mm/sec): 200, Size: 16, Motor Type: Step motor (24‑V DC servo), Motor mounting position: Basic type / R type, Motor options: No options, Mounting support: Without side holder, Actuator/cable type: Standard cable, Actuator cable
Thrust Force(N): 55, Noise Filters: Not Provided, Table Length L1(mm): 130.3, Operating Environment: Standard, Positioning Repeatability(µm): ±50, Maximum Velocity(mm/sec): 200, Size: 16, Motor Type: Step motor (24‑V DC servo), Motor mounting position: Basic type / R type, Motor options: No options, Mounting support: Without side holder, Actuator/cable type: Standard cable, Actuator cable
Thrust Force(N): 55, Noise Filters: Not Provided, Table Length L1(mm): 174.3, Operating Environment: Standard, Positioning Repeatability(µm): ±50, Maximum Velocity(mm/sec): 200, Size: 16, Motor Type: Step motor (24‑V DC servo), Motor mounting position: Basic type / R type, Motor options: No options, Mounting support: Without side holder, Actuator/cable type: Standard cable, Actuator cable
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or