Function: 3 (3 Position Closed Center), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 3 (Common), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: D (Push-turn Locking Slotted Type), A, B Port Size: 01 (1/8), Thread: T (NPTF
Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8), Thread: N (NPT)
Function: 2 (2 Position Double), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: T (Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8)
Piping: 40 (Base Mounted), Stations: 10 Stations, A, B Port: 01 (Rc1/8)
Piping: 41 (Base Mounted), Stations: 2 Stations, A, B Port: 01 (Rc1/8)
Piping: 41 (Base Mounted), Stations: 3 Stations, A, B Port: 01 (Rc1/8)
Piping: 41 (Base Mounted), Stations: 5 Stations, A, B Port: 01 (Rc1/8)
Piping: 42 (Base Mounted), Stations: 2 Stations, A, B Port: 01 (Rc1/8)
Piping: 42 (Base Mounted), Stations: 3 Stations, A, B Port: 01 (Rc1/8)
Piping: 42 (Base Mounted), Stations: 4 Stations, A, B Port: 01 (Rc1/8)
Piping: 42 (Base Mounted), Stations: 5 Stations, A, B Port: 01 (Rc1/8)
Piping: 42 (Base Mounted), Stations: 6 Stations, A, B Port: 01 (Rc1/8)
Piping: 42 (Base Mounted), Stations: 7 Stations, A, B Port: 01 (Rc1/8)
Piping: 42 (Base Mounted), Stations: 8 Stations, A, B Port: 01 (Rc1/8)
Piping: 42 (Base Mounted), Stations: 9 Stations, A, B Port: 01 (Rc1/8)
Piping: 42 (Base Mounted), Stations: 10 Stations, A, B Port: 01 (Rc1/8)
Piping: 42R (Base Mounted), Stations: 3 Stations, A, B Port: 01 (Rc1/8)
Piping: 42R (Base Mounted), Stations: 5 Stations, A, B Port: 01 (Rc1/8)