Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: 2, Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector), Surge Suppressor: U (w/Light & Surge Voltage
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: J (w/Indicator, Right Flange Surface), Version: 2, Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 3 (110 VAC, 50/60 Hz), Electrical Entry: G [Grommet (Lead Wire Length 300mm)], Surge Suppressor: Z
Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 50, Flange Type: KF(NW), Port Direction: w/o Indicator, Rear Flange Surface; Std.
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 3-Port Valve, Solenoid Type: Single, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 150°C (with heater
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 3-Port Valve, Solenoid Type: Single, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 50, Seal Type: Bellows Seal, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60℃ (no heater),
Type: Electromagnetic valve used under high vacuum, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 3-Port Valve, Solenoid Type: Single, Switching Type: 2-Position Normally Closed, Electromagnetic Valve Drive Type: Air Pilot, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 16, Seal Type: Bellows Seal, Indicator: With indicator, Pilot Port Direction
Valve Type: Normally Closed, Bellows Seal, Flange Size: 16, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std.
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std.
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std.
Valve Type: Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std.
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std.
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std.
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/Indicator, Flange Side, Temperature: 5 to 150°C, with 80°C at 100VAC, 100°C at 200VAC Heater, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment
Valve Type: Normally Closed, Bellows Seal, Flange Size: 50, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std.
Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/Indicator, Right Flange Surface, Temperature: 5 to 150°C, with 80°C at 100VAC, 100°C at 200VAC Heater, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface
switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25, 32, 40, 50, 63, 80, 100, Standard stroke range *: 5 to 100, Port threads: M *; Rc, NPT or G *, Auto switch capable, CYL, COMPACT, DOUBLE ROD, ACTUATOR, CQ2-Z COMPACT CYLINDER, NW
switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25, 32, 40, 50, 63, 80, 100, Standard stroke range *: 5 to 100, Port threads: M *; Rc, NPT or G *, Auto switch capable, CYL, COMPACT, DOUBLE ROD, ACTUATOR, CQ2-Z COMPACT CYLINDER, NW
5 to 100 , Mountings include: Through hole (standard), threaded, foot, and rod flange, Auto switch capable, CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, NW, 50MM NCQ2-Z DOUBLE-ROD, .00000 lb, SeriesModelActionNoteCQ2StandardCQ2WDouble acting, Double rodExcept with rubber bumper
switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25, 32, 40, 50, 63, 80, 100, Standard stroke range *: 5 to 100, Port threads: M *; Rc, NPT or G *, Auto switch capable, CYL, COMPACT, DOUBLE ROD, ACTUATOR, CQ2-Z COMPACT CYLINDER, NW
mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25, 32, 40, 50, 63, 80, 100, Standard stroke range *: 5 to 100, Port threads: M *; Rc, NPT or G *, Auto switch capable, CYL, COMPACT, DOUBLE ROD *LQA, ACTUATOR, NCQ2 COMPACT CYLINDER, NW