SMC Corporation of America
Elite Part Number Search
Search Results "ZZK202A-A2S0-L-A"

Wire Length 0.3 m, Surge Suppressor: Light + Surge Supressor, Manual Override: Slotted Locking Type, Switch/Filter: D [Digital Pressure Switch for Vacuum (ZSE30A) + Filter], Output: NPN Open Collector, 1 Output, Unit Specification: SI Unit Only, Lead Wire: For Switch D: Lead Wire w/Connector, Length 2m; For Switch E: Grommet/Lead Wire length 3m, Adjusting Needle/Bracket: Lock Nut + Bracket A

Specification: w/Unit Switching Function, Initial Value psi, Lead Wire: For Switch D: Lead Wire w/Connector, Length 2m; For Switch E: Grommet/Lead Wire length 3m, Adjusting Needle/Bracket: Lock Nut + Bracket A or B, CE Compliant: CE Compliant, DC Only

Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Pilot Valve: DC 1W (With Light: 1.05 W); AC or None in Case of No Valve, Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Pilot or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Port

ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, MINIATURE NON-LUBE, ACTUATOR, MCN ROUND BODY CYLINDER, HE, 20MM MCN DBL-ACT AUTO-SW, .71650 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, MINIATURE NON-LUBE, ACTUATOR, MCN ROUND BODY CYLINDER, LE, 32MM MCN DBL-ACT AUTO-SW, 1.98416 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, MINIATURE NON-LUBE, ACTUATOR, MCN ROUND BODY CYLINDER, LE, 32MM MCN DBL-ACT AUTO-SW, 2.20462 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, MINIATURE NON-LUBE, ACTUATOR, MCN ROUND BODY CYLINDER, ME, 40MM MCN DBL-ACT AUTO-SW, 3.08121 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, MINIATURE NON-LUBE, ACTUATOR, MCN ROUND BODY CYLINDER, LE, 32MM MCN DBL-ACT AUTO-SW, 2.20462 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, MINIATURE NON-LUBE, ACTUATOR, MCN ROUND BODY CYLINDER, ME, 40MM MCN DBL-ACT AUTO-SW, 3.22731 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, MINIATURE NON-LUBE, ACTUATOR, MCN ROUND BODY CYLINDER, LE, 32MM MCN DBL-ACT AUTO-SW, 2.14950 lb

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C4H (One-touch Fitting ΓΈ4mm, Straight Type), Option 1: L (Lead Wire w/Connector, 2m)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, MINIATURE NON-LUBE, ACTUATOR, MCN ROUND BODY CYLINDER, LE, 32MM MCN DBL-ACT AUTO-SW, 1.78819 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com