Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2E, VFS5000, 2.48904 lb
Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DB, ISE40/50/60 1/4 NPT VERSION, .19841 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, SILENCER, AIRLINE EQUIPMENT, AN SILENCER, CB, AN 1/8INCH, .02204 lb
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, PLUG CONNECTOR ASSY, VQ100, VALVE, VQ1000 NO SIZE RATING, .01100 lb
Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DX, ISE40/50/60 1/4 (MISC.
The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, 1X, ISE40/50/60 OTHER SZ (OTHER), .40234 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator
This is a legacy product, and replaced byISE20B-R-N01-W-X500, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .17416 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, PLUG CONNECTOR ASSY, VQ100, VALVE, VQ1000 NO SIZE RATING, .00880 lb
The settings of the master pressur, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .30950 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, LEAD WIRE ASSY, VALVE, VQ1000 NO SIZE RATING, .00493 lb
Hz), 240 VAC (50/60 Hz) 12, 24 VDC?
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, LEAD WIRE ASSY, VALVE, VQ1000 NO SIZE RATING, .00462 lb
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, DIAPH.-AR100 (NON-REL), AIRLINE EQUIPMENT, AR NO SIZE RATPART, .96800 lb
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, LEAD WIRE ASSY, VALVE, VQ1000 NO SIZE RATING, .00449 lb
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, PLUG CONNECTOR ASSY, VQ100, VALVE, VQ1000 NO SIZE RATING, .05940 lb
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, LEAD WIRE ASSY, VALVE, VQ1000 NO SIZE RATING, .00594 lb
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, LEAD WIRE ASSY, VALVE, VQ1000 NO SIZE RATING, .00559 lb
, Choice of 2 piping directions rear and bottom ported , Panel or bracket mounting , Resolution and MPa/kPa switching function , Analog current output, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DX, ISE40/50/60 1/4 (MISC.
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, TRACK GASKET, VALVE, VFS5000 SOL VALVE 4/5 PORT, 21, VFS5000, 1.70896 lb
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, LEAD WIRE ASSY, VALVE, VQ1000 NO SIZE RATING, .00471 lb