Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, 3 PORT BASE MOUNTED SOLENOID VALVE, 3 PORT SOLENOID VALVE, VVD, 24 lb
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, 3 PORT BASE MOUNTED SOLENOID VALVE, 3 PORT SOLENOID VALVE, VVD, 24 lb
Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, BODY PORTED MANIFOLD, 3 PORT SOLENOID VALVE, VVD, 349 lb
Plug-in manifold for VQ1*0* valve, Individual lead wire type, P and R ports on one side for space savings, Maximum 8 stations available as standard, 16 port sizes available, Optional DIN rail mount, VV5Q manifold, 4/5 PORT SOLENOID VALVE, J57, 0.543 lb
Individual lead wire type, P and R ports on one side for space savings, Maximum 8 stations available as standard, 12 port sizes available, Optional DIN rail mount, VV5Q manifold, 4/5 PORT SOLENOID VALVE, J57, 0.806 lb
Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, BASE MOUNTED MANIFOLD, 3 PORT SOLENOID VALVE, VVD, 544 lb
Individual lead wire type, P and R ports on one side for space savings, Maximum 8 stations available as standard, 12 port sizes available, Optional DIN rail mount, VV5Q manifold, 4/5 PORT SOLENOID VALVE, J57, 0.368 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, PLUG IN, 4/5 PORT SOLENOID VALVE, G92, 84 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, NON PLUG IN, 3-PORT, 4/5 PORT SOLENOID VALVE, G92, 84 lb
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, 3 PORT BODY PORTED SOLENOID VALVE, 3 PORT SOLENOID VALVE, VVD, 24 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE 2POS/DBL, W/O CONNECTOR, 4/5 PORT SOLENOID VALVE, 0.03 lb
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, 3 PORT BODY PORTED SOLENOID VALVE, 3 PORT SOLENOID VALVE, 24 lb
Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, VQZ100 Body Ported Manifold, 3 PORT SOLENOID VALVE, 83 lb
Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, VQZ200 Body Ported Manifold, 3 PORT SOLENOID VALVE, 68 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, NON PLUG IN, 4/5 PORT SOLENOID VALVE, 78 lb
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less, VALVE, NON PLUG IN, 4/5 PORT SOLENOID VALVE, 78 lb
Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, VQZ200 Base Mounted Manifold, 3 PORT SOLENOID VALVE, 506 lb
Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, VQZ300 Base Mounted Manifold, 3 PORT SOLENOID VALVE, 209 lb
Please contact us for the latest version.sales@ocaire.com, VALVE, SOFT START 3/8, VALVE, AV SOFT START UP BODY PORT, HA, AV BODY PORT 3/8 PT, 1.25640 lb, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable
Please contact us for the latest version.sales@ocaire.com, VALVE, SOFT START 1/4, VALVE, AV SOFT START UP BODY PORT, EA, AV BODY PORT 1/4 NPT, .00000 lb, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable