SMC Corporation of America
Elite Part Number Search
Search Results "HRS200-A-46-AS"

When disassembling cylinders, grip the double flat part of either the head cover or the rod cover with a vise and loosen the other side with a wrench or a monkey wrench, etc., and then remove the cover. When re-tightening, tighten approximately 2 degrees more than the original position. 20 A

Pressure Momentary change P1 P2 Set value Anti-chattering function Devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the primary pressure.


Note) The set nuts of the AR-A series and those of the AR-B/AR-D series differ in size as well as part number.
The AR-A series catalog can be found <a href="/webcatalog/en-jp/seriesList/?type=GUIDE&id=AR-A-E" target="_blank">herea>.
The AR-B series catalog can be found <a href="/webcatalog/en-jp/seriesList/?type=GUIDE&id=AR-2-E" target="_blank">herea>.

Contacts/Bulb gland Pressure Source Nil W Nil B C 1a1b (Standard) 2ab Contact Warning Enclosure Type A 20a (Standard) Type A 20b Type A 20c Bulb gland 1.

Pressure Momentary change P1 P2 Set value Anti-chattering function Devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the primary pressure.

With a model that has the maximum flow rate line below the obtained intersecting point, the flow rate will be exceeded, thus leading to a problem such as being unable to satisfy the specifications.

The maximum piston speed for retraction is approximately 70% that of extension. 848 Dual Rod Cylinder/Compact Type CXSJ 2122CXSJ/ 1112Auto Switch Proper Mounting Positions (Detection at Stroke End) CXSJ6 / CXSJ6 11122122D B (mm) D-M9 23 (24) 2 (1) 13 (11.5) 8 (9) D-A93 19 (20) 14.5 (15.5) 6.5 (7.5) Symbol A B C D Note 1) A C Note 1) The above mentioned values are indicated as a guide for


As shown in the figure below explaining the dual stroke cylinder functions, in the first stage, the stroke that can be operated when port A is pressurized is the A stroke.
In the second stage, as the piston rod is already operating the A stroke, the stroke that can be operated by pressurizing port C is the B-A stroke.

Seal kit includes a grease pack (10 g). Order with the following part number when only the grease pack is needed.

A flow rate of up to 9 can be accumulated. The accumulated flow rate is reset when the power supply turns OFF. (PF2A7H maintains the values.) Real-time switch output, accumulated switch output, or accumulated pulse output can be selected as an output type.

Since VXZ series valves are operated with zero differential pressure, the min. operating pressure differential is 0 MPa, which is the same as that of VX2 series direct operated valves.
The differences are as follows.
VXZ series valves feature a large orifice diameter, a medium flow rate, and a wide pressure range.

(Note) Indicator oanel Denatured PPO Swagelok* IS a registered trademark 0 1 Crawford Fitting Co. VCRlI lS a registered trademark. of Cajon Co.

Pressure display on the scale plate is just as a reference guide. For an accurate setting, measure it by pressure gauge. Warning 3. Internal circuit of contact protection box 1. When changing piping by hand, hold body. Electrical wire must not be subjected to excessive force. It may cause a malfunction or damage. 2. Do not drop nor apply excessive force.

BEA, EB: 57.6 (3.2) [A, BEA, EB: 45 (2.5)] VFRA4311-04 3 8 VFRA4411-03 3 position exhaust center 1.2 1 8 PA, B: 51 (2.8) A, BEA, EB: 57.6 (3.2) [A, BEA, EB: 45 (2.5)] 1 2 VFRA4411-04 3 8 65 (3.6) [PA, B: 30.6 (1.7)] VFRA4511-03 3 position pressure center 1.2 1 8 VFRA4511-04 1 2 67 (3.7) [PA, B: 30.6 (1.7)] ( ): in case of normal position.

Accessories/Tools Tube Cutter Series TK Tube Cutter: TK-1 Perpendicular cutting Reduced operating force Enclosure/safety lock contained Note) Never cut metals such as electric wires. Part No. TK-1 Nylon, soft nylon, polyurethane, and other soft plastic tube Tube material Tube O.D. Weight 13mm or less 140g Tube Cutter: TK-2 Possible to cut a tube up to 18mm.

Remote control type Easy to reset after installation as a result of the remote controller Optimum for installing where it is difficult to reach because the controller can be operated in an easily accessible location.

The AF-D series of modular air filters brings a modern appearance to SMC's line of filters while maintaining the high performance of our other series.  These 5 μm units can serve as appropriate filtration for many applications or as a pre-filter for fine filtration/coalescing units. 

The AF-D series of modular air filters brings a modern appearance to SMC's line of filters while maintaining the high performance of our other series.  These 5 μm units can serve as appropriate filtration for many applications or as a pre-filter for fine filtration/coalescing units. 

The AF-D series of modular air filters brings a modern appearance to SMC's line of filters while maintaining the high performance of our other series.  These 5 μm units can serve as appropriate filtration for many applications or as a pre-filter for fine filtration/coalescing units. 

Recommended valve series, as well as the sonic conductance of each valve, are listed in the ZH-X185 series catalog. Each valve is capable of providing the required pressure to the ZH-X185 series vacuum flow, so the flow rate can be 3 times as high as the air consumed by each vacuum flow. The ZH-X185 series catalog can be found <a href="/webcatalog/en-jp/seriesList/?