Example) AW30K-03BE-1N-B B AW 30 03 BE K q w e r t y q Body size 20 30 40 60 Symbol Description w With backflow function Nil Without backflow function K Note 1) With backflow function + e Pipe thread type Nil Rc N Note 2) NPT F Note 3) G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 r Port size 10 1 + a Mounting Nil Without mounting option B Note 5) With bracket H With set nut (for panel mount
Auto switches are shipped together (not assembled). 464 Slide Unit/Double Rod Type Series CX2 Specifications Type Air-hydro type Non-lube Air Hydraulic fluid Fluid 1.5 MPa Proof pressure 1.0 MPa Max. operating pressure CX2N10 CX215 CX225 0.15 MPa 0.15 MPa Min. operating pressure 0.10 MPa Ambient and fluid temperature 10C to +60C 30 to 200 mm/s Refer to Table (1).
1.206 ROTARY ACTUATORS RACK & PINION TYPE SERIES NCRA1 RACK & PINION TYPE ROTARY ACTUATOR BORE SIZES 30, 50, 63, 80, 100MM SERIES NCRA1 90,180 rotation Optional magnetic piston for autoswitches Low friction resistance T E C H N I C A L SPECIFICATIONS Fluid Air (No Lubrication) Proof Pressure 1.5MPa / 225 PSI Max Operating Pressure 1MPa / 150 PSI Min Operating Pressure 0.1MPa / 15 PSI Ambient
Operation External pilot type Internal pilot type AC, 100 VDC or more Operating pressure range -101.2 kPa to 0.9 MPa Equivalent operating pressure Min. 0.2 MPa 0.2 to 0.9 MPa In the case of indicator light assembly Terminal no. 1 (+) External pilot pressure Response time (1) 30 ms or less (at the pressure of 0.5 MPa) Coil Max. operating frequency 5 c/s (Min. operating frequency: 1 c/30 days
1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?
C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)14.1 scfm (400 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)21.2 scfm (600 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)14.1 scfm (400 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)14.1 scfm (400 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)21.2 scfm (600 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)21.2 scfm (600 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)21.2 scfm (600 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
The VQ20/30 series is a pilot operated, two port multi-media valve. The series is compact and lightweight with a large flow capacity.
The VQ20/30 series is a pilot operated, two port multi-media valve. The series is compact and lightweight with a large flow capacity.
The VQ20/30 series is a pilot operated, two port multi-media valve. The series is compact and lightweight with a large flow capacity.
The VQ20/30 series is a pilot operated, two port multi-media valve. The series is compact and lightweight with a large flow capacity.
1220 (1.5)150 (1.0)23~140 F (-5 ~ 60 C)3-30 (0.02~0.2)ADC, AC2A-FADCADC, AC2A-FZDC, AC2A-F2.43 (1.1)B25PK50A-MP1.0-N02M (0~160 psig) Std. NAR O 25K50A-MP2.0-N02M (0~30 psig) Std. NAR O 35
1220 (1.5)150 (1.0)23~140 F (-5 ~ 60 C)3-30 (0.02~0.2)ADC, AC2A-FADCADC, AC2A-FZDC, AC2A-F2.43 (1.1)B25PK50A-MP1.0-N02M (0~160 psig) Std. NAR O 25K50A-MP2.0-N02M (0~30 psig) Std. NAR O 35
1 1/2220 (1.5)150 (1.0)23~140 F (-5 ~ 60 C)3-30 (0.02~0.2)AC2A-FADCAC2A-FAC2A-F5.51 (2.5)?K50A-MP1.0-N02M (0~160 psig) Std. NAR O 25K50A-MP2.0-N02M (0~30 psig) Std. NAR O 35
A maximum effective area of 670mm (2B) can be covered by the combination of an ultra-compact electro-pneumatic pilot valve (22.4 X 30 X 39) and a 3 port, high-capacity exhaust main regulator (VEX1*00 series).