Use 0.3 to 0.7 times the thrust (differs depending on the operating speed) as a guide for actual use. g: Gravitational acceleration Dynamic moment M Mounting orientation Dynamic load FE Horizontal Ceiling Wall Vertical Z 1.4 100 x a x mn x g a a 1 3 x FE x Z ME Dynamic moment Dynamic moment ME does not occur.
Symbol X201 Machined Bleed Port M5 Thread 1 Regulator with a M5 thread machined on the relief port in order to connect it to the bleed port. X201 Standard model no. Machined bleed port M5 thread Dimensions Other dimensions are the same as the standard type.
(A cylinder with 4 bore has been added as a compact type to the existing CJ2: 6 double acting cylinder.)
Therefore, in the case of the single vane type, use a rotary actuator body for 270, and in the case of the double vane type, use a rotary actuator body for 100.
Cushion adjustment is not necessary because the model can perform smooth acceleration and deceleration in a wide range of strokes without an adjusting cushion. 1. The 10-AS series throttle type speed controllers are recommended for speed adjustment.
Make sure to provide a bypass pipe in case the flow of air cannot be stopped during maintenance, such as when replacing the adsorption agent. 2. Install the dryer horizontally. 3. Do not allow the weight of piping to lie directly on air dryer. 4. Do not connect a tube smaller than the port size to the inlet side.
These units cannot be used in an environment or in a location that is exposed to synthetic oil, thinner, acetone, alcohol, organic solvents such as ethylene chloride, chemicals such as sulfuric acid or nitric acid, cutting oil, kerosene, gasoline, or a threadlock agent, etc., because they will be damaged.
(mm) Comparison of total cylinder length with standard style 20 G13 25 G13 32 G13 40 G16 Mounting LBoss-cut basic (BZ) LBoss-cut trunnion (UZ) LBoss-cut flange (FZ) Conversion into the cylinder operating pressure: Selecting The Low Friction Direction To use the air cylinder as a balancer, pressurize it only from one of the ports as shown in the application example, and keep the other port
The element could be damaged if the difference in internal and external pressures exceeds 0.1MPa. w Do not use it with anything other than dry air (such as air containing moisture). e Make sure to install a micromist separator (AMD Series), a micromist separator with a prefilter (AMH Series) or a supermist separator (AME series), on the primary side. r The bracket that is provided with the
Cylinder ports are NAMUR hole pattern. 3-12-4 5 NAMUR Interface 5 Port Solenoid Valve Series VFN2000N/3000N NAMUR Mounting Pattern Axis A-A' can be aligned to suit. A 24 VK M5 thread 8 deep, with or without insert depending on base material. VZ 32 VF A' VFR Coding stud.
Note Component Parts Replacement Parts ZCU Description Material Sound absorbing material A No. No. Sound absorbing material PVF AMJ PVF P397114 Suction cover q o P397230 When ordering a vacuum pressure gauge or a digital vacuum pressure switch separately, use the part numbers shown in the option specifications on page 13-7-5. Front cover A w !0 Misc.
This product uses a nickel hydride battery. Nickel hydride batteries is considered a dangerous good (Class 9) for maritime transport according to UN regulations. This product is NOT considered a dangerous good for maritime transport (as of August 2012).
These units cannot be used in an environment or in a location that is exposed to synthetic oil, thinner, acetone, alcohol, organic solvents such as ethylene chloride, chemicals such as sulfuric acid or nitric acid, cutting oil, kerosene, gasoline, or a threadlock agent, etc., because they will be damaged.
Lightweight: 30 g(LVM11)/34 g(LVM1R/LVM11) A Weight savings by adopting resin as a standard B Power consumption: 1 w(LVM11)/1.5 w(LVM1R/LVM11) LVM11 Applications: Various analytical and inspection equipment Analytical instruments for blood, urine, immune system, etc.
Make sure to provide a bypass pipe in case the flow of air cannot be stopped during maintenance, such as when replacing the adsorption agent. 2. Install the dryer horizontally. 3. Do not allow the weight of piping to lie directly on air dryer.
If a follow-up operation is performed at a duty ratio of 50% or higher, the upper limit value may change.
Pressure loss in air blow is significantly reduced with an effective sectional area as large as 30 mm2. Gun, a large reduction in air consumption can be attained. un, a large reduction in air consumption can be attained. With an SMC Blow Gun, a large reduction in air consumption can be attained. With an SMC Blow Gun, a large reduction in air consumption can be attained.
A 24 V100 M5 thread 8 deep, with or without insert depending on base material. SY 32 SYJ A' VK Coding stud.
Lightweight: 30 g(LVM11)/34 g(LVM1R/LVM11) A Weight savings by adopting resin as a standard B Power consumption: 1 w(LVM11)/1.5 w(LVM1R/LVM11) LVM11 Applications: Various analytical and inspection equipment Analytical instruments for blood, urine, immune system, etc.
When disassembling cylinders, grip the double flat part of either the head cover or the rod cover with a vise and loosen the other side with a wrench or a monkey wrench, etc., and then remove the cover. When re-tightening, tighten approximately 2 degrees more than the original position. 20 A