PRODUCT NAME Fieldbus system IO-Link Master Unit MODEL / Series / Product Number EX600-LAB1 EX600-LBB1 Table of Contents Safety Instructions 2 System Outline 8 Assembly 10 Mounting and Installation 12 IO-Link Master Unit Model Indication and How to Order 15 Summary of Product parts 15 Mounting and Installation 16 LED Display 17 Specification 19 Maintenance 21 Parameter Setting 22 Diagnosis 27

No.EX-OMN0037CN-A / EX600-AXA EX600-AYA EX600-AMB SMC 3 9 10 12 12 14 15 15 16 16 LED 18 19 19 24 25 25 26 26 LED 27 28 28 32 33 33 34 34 LED 36 37 37 44 -1No.EX-OMN0037CN-A 45 46 46 46 46 46 47 -2No.EX-OMN0037CN-A (ISO/IEC)(JIS) 1 2 *1 ISO 4414: Pneumatic fluid power -General rules relating to systems.

Panel mount adapter ZS-46-B Panel mount adapter + Front protective cover ZS-46-D Front protective cover ZS-27-01 Lead wire with connector ZS-46-5L 5-wire, 2 m Connector for sensor lead wire ZS-28-C -8No.PS-OMW0014-B Summary of Product parts Names of individual parts Operation light: Displays the switch operating condition.

Remarks Sensor connector (For PFMB) ZS-28-C-1 Sensor connector (For PFMC and PF3A7) ZS-28-CA-4 Bracket A ZS-46-A1 Self tapping screws: Nominal size 3 x 8L (2 pcs) Bracket B ZS-46-A2 Self tapping screws: Nominal size 3 x 8L (2 pcs) Panel mount adapter ZS-46-B Panel mount adapter + Front protective cover ZS-46-D Lead wire with connector ZS-46-5L 5 cores, 2 m Front protective cover ZS-27-01

No.PF-OMO0007CN / / PF2A7## 2 10 12 13 15 15 16 17 19 20 21 22 25 F_1 26 F_2 () 27 F_3 28 30 31 32 32 34 35 35 37 38 40 -1No.PF-OMO0007CN (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (

(page 27.) Improper operation of the flow adjustment valve. Check flow rate characteristics of the supply pressure and flow rate adjustment valve. Insufficient supply pressure Increase supply pressure. Stop valve is locked. Check for the screw mounted for holding the handle. Stop the flow rate by loosening the screw. Stop valve does not stop the flow rate. Stop valve fails.

When ON: Orange LED turns on. 1/2 27 mm Error Name Display Content Remedy Product series is displayed 3/4 32 mm Set value Sets the ON or OFF point of the switch output. 50% of rated flow Unit display Displays the unit selected. OUT1 over current error A load current of 80 mA or more is flowing to the switch output (OUT1). Turn the power off and remove the cause of the over current.

Piping port (OUT side) Initial processing in the product Lead wire with M8 connector (4 pins) (Option) 3/8 24 mm Approx. 3 seconds (the output remains off for this period) Approx. 1 second Flow adjustment valve (When flow adjustment valve is selected) 1/2 27 mm Output specification identification display * 3/4 32 mm Temperature sensor (When temperature sensor is selected) 1 41 mm Approx.

WIN ACCUMU PLS HYS 2. 1_P/1_N(27 ) Add/dEC (29 ) 3. P1L/n1L P1H/n1H H1 (28 ) P1AH/n1AH P1AL/n1AL P1dH/n1dH P1dL/n1dL P_1/n_1 H_1 (28 ) (29 ) 4. SoG/SoR/REd/GRN(31 ) 5. [F 1] OUT1 -26No.PF-OMN0011CN-C 1. [F 1] [oUt1] 2. ON-OFF -27No.PF-OMN0011CN-C 3. a. ([n_1]) (31 ) b.

(LED is OFF in SIO mode) 3/8 24 mm With the temperature sensor 1/2 27 mm Approx. 1 second Reset the accumulated flow once. (Press the SET and DOWN button for 1 second or longer.) Item Content Default setting The accumulated flow range is exceeded. (The decimal point position changes depending on the flow range.)

[Measurement condition] [Port size] Measurement: Tap water LFE13/8 inch Pressure: 0.2 MPa LFE23/4 inch LFE31 inch Straight pipe length (mm) Model D 5 D LFE1 11 55 LFE2 21 105 LFE3 27 135 -68No.LV50***-OMQ0002-G Stability Fluctuation of the display and the analogue output can be reduced by lengthening the response time setting. 4.0 3.5 3.0 Stability [%F.S.]

[Measurement condition] [Port size] Fluid: Tap water LFE13/8 inch Pressure: 0.2 MPa LFE23/4 inch LFE31 inch Straight pipe length (mm) Model D 5 D LFE1 11 55 LFE2 21 105 LFE3 27 135 -69No.LFE*-OMZ0011 Stability Fluctuation of the display and the analogue output can be reduced by lengthening the response time setting. 4.0 3.5 3.0 Stability [%F.S.]

Operation start timer setting status signal output Operation stop timer setting status signal output Recovery from power failure setting status signal output Anti-freezing setting status signal output Contact input signal 1 pass through signal output Contact input signal 2 pass through signal output Warming up function setting status output Contact output 2 operation Setting and checking 27

output Operation stop timer setting status signal output Recovery from power failure setting status signal output Anti-freezing setting status signal output Contact input signal 1 pass through signal output Contact input signal 2 pass through signal output Warming up function setting status output Signal output during automatic fluid filling Contact output 2 operation Setting and checking 27

Valve (Material: SUS304) 6 Valve seal 2 (Maintenance part) 3 (Valve seal 2) Nut assembly (Maintenance part) (Set of a nut and a washer) 9 Washer (Material: SUS304 or equivalent) Nut (Material: SUS304 or equivalent) (Shaft) 11 XL-OMS0001-B 5-2.Dimensions C E C E E (KF flange) Fd (K flange) Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27

XL1A25-60S-2 1 2 H5 AC100V 600/130 800/180 / AC200V 2400/130 3200/180 1[W] 216 PTC 200V PTC 200 150 100V PTC 0 5 10 15 20 25 30 ( 30 10 XL-OMY0001 5 5-1 1 , SUS304 8 4 SUS304 10 , SUS316L 7 5 A6063 2 1 6 SUS304 3 2 9 2 SUS304 SUS304 11 XL-OMY0001 5-2 C E E E KF K Fd Fn C D H B A G A mm A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27

Material: SUS304) 6 3 Valve seal 2 (Maintenance part) Nut assembly (Maintenance part) (Set of a nut and a washer) 9 (Valve seal 2) Washer (Material: SUS304 or equivalent) Nut (Material: SUS304 or equivalent) (Shaft) 11 XL-OMV0007 5-2.Dimensions Size 16, 25, 40 E C E (KF flange) Fn C E D J H B A G A Unit: (mm) Model A B C D E Fn Fd G H J XLC-16-2 40 108 38 20 30 17 44 19 XLC-25-2 50 121 48 27

SUS304) 6 3 Valve seal 2 (Maintenance part) Nut assembly (Maintenance part) (Set of a nut and a washer) 9 (Valve seal 2) Washer (Material: SUS304 or equivalent) Nut (Material: SUS304 or equivalent) Shaft (Material: SUS304) 7 11 XL-OMV0017 5-2.Dimensions C E C E E (KF flange) (K flange) Fd Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLF-16-2 40 108 38 20 30 17 44 XLF-25-2 50 121 48 27

XMC Exterior dimensions C D L1 L2 Fn Fc C (Fc) (KF Flange) (CF Flange) J H B A G A Unit:mm Model A B C D Fn Fc G H J P.C.D L1 L2 XMC-16 40 110 38 1 30 34 17 40 26 P.C.D 27 6x4.4 XMC-25 50 120 48 1 40 26 39 28 XMC-40 65 171 66 2 55 70 41 63 36 P.C.D. 58.7 6x6.6 C D L1 L2 Fn Fd Fc C (Fc) (KF Flange) (K Flange) (CF Flange) H J K B A G A Unit:mm Model A B C D Fn Fc Fd G H J K P.C.D L1 L2 XMC-

Dimensions XMH series / Angled Valve C D L1 L2 A Fn Fc C (Fc) (CF Flange) (KF Flange) H J H B G A Unit:mm Table 5 Model A B C D Fn Fc G H J P.C.D L1 L2 XMH-16 40 100.5 38 1 30 34 17 35 18 P.C.D 27 6x4.4 XMH-25 50 114 48 1 40 26 41 21.5 XMH-40 65 162.5 66 2 55 70 41 57 30 P.C.D 58.7 6x6.6 XMH-50 70 179.5 79 2 75 52 70 35 XYH series / Straight Valve D G C C B H Fn J (KF Flange) 45 Unit: mm